Fuel Control Actuator - Remove and Install
- Disconnect wiring harness (1) from fuel control actuator (5).
- Remove nut (4) and remove linkage (3).
- Remove four nuts (2). Remove fuel control actuator (5) from the engine.
Show/hide table
Illustration 1 | g00597502 |
Typical example |
- Position fuel control actuator (5) on the engine and install four nuts (2).
- Install linkage (3) on fuel control actuator (5) and install nut (4).
- Connect wiring harness (1) to fuel control actuator (5).
Show/hide table
Illustration 3 g00597521 Typical example - Open the fuel control actuator completely. Adjust the linkage to an angle of 26 ± 2 degrees. Ensure that there is an equal amount of slack on each end of the linkage.
Show/hide table
Illustration 2 | g00597502 |
Typical example |
Caterpillar Information System:
Electronic Modular Control Panel II (EMCP II) For PEEC Engines CID 331 FMI 2 Switch (Engine Control) Incorrect Signal - Test
G3500 Engines Electronic Sensor - Remove and Install
3114, 3116 and 3126 Industrial, Marine and Generator Set Engines Gear Group (Front)
G3500 Engines Carburetor - Assemble - High Pressure
3034 Engine for Caterpillar Built Machines Turbocharger - Install
3500B Engines and 3500 Engines with EUI Option Emergency Stop Switch
G3500 Engines Carburetor - Disassemble - High Pressure
G3500 Engines Carburetor - Assemble - High Pressure
3500B Engines Air Starting Motor - Remove
3114, 3116 and 3126 Industrial, Marine and Generator Set Engines Front Housing and Covers
G3606 and G3608 Engines Hydraulic Tank (Hydrax) - Remove and Install
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Harness Code - Troubleshoot
3500B Engines and 3500 Engines with EUI Option Engine Control Switch (ECS)
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 333 FMI 3 Alarm Module Control Voltage Above Normal - Test
G3500 Engines Fuel Control Valve - Remove and Install
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 333 FMI 4 Alarm Module Control Voltage Below Normal - Test
G3500 Engines Gas Pressure Regulator Solenoid - Remove and Install
G3606 and G3608 Engines Actuator (Hydrax) - Remove
3003, 3013, 3014 and 3024 Engines for Caterpillar Built Machines Cylinder Head - Install
3500B Engines Air Starting Motor - Install
3500B Engines Air Starting Motor - Disassemble
G3500 Engines Gas Pressure Regulator - Remove - Low Pressure
G3500 Engines Gas Pressure Regulator - Install - Low Pressure
G3500 Engines Gas Pressure Regulator - Remove - High Pressure