Removal Procedure
Required Tools     | |||
---|---|---|---|
Tool     | Part Number     | Part Description     | Qty     |
A     | 9N-6379     | Air Cleaner Adapter Boot     | 1     |
B     | 4P-2706     | Protection Cap     | 1     |
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
Sulfuric Acid Burn Hazard, may cause serious personal injury. The clean gas induction cooler may contain a small amount of sulfuric acid. The use of fuel with sulfur levels greater than 15 ppm may increase the amount of sulfuric acid formed. The sulfuric acid may spill from the CGI cooler during service of the engine and may travel to other downstream components. The sulfuric acid will burn the eyes, skin and clothing on contact. Always wear the appropriate personal protective equipment (PPE) that is noted on a material safety data sheet (MSDS) for sulfuric acid. Always follow the directions for first aid that are noted on a material safety data sheet (MSDS) for sulfuric acid. |
- Drain the coolant from the cooling system into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant - Change".
- Loosen clamp (1) .
Illustration 1 | g01294180 |
- Remove bolt (2) in order to disconnect tube (3) .
- Disconnect hose (4) .
- Remove tube assembly (5) .
- Install Tooling (A) on the inlet side of the clean gas induction cooler.
- Install Tooling (B) on the outlet side of the clean gas induction cooler.
- Remove nut (6) . Remove bolts (7) .
Illustration 2 | g01294214 |
- Remove clean gas induction cooler (8) .
Installation Procedure
Required Tools     | |||
Tool     | Part Number     | Part Description     | Qty     |
A     | 9N-6379     | Air Cleaner Adapter Boot     | 1     |
B     | 4P-2706     | Protection Cap     | 1     |
C     | 5P-3931     | Anti-Seize Compound     | -     |
- Position clean gas induction cooler (8) . Install bolts (7) and install nut (6) .
Illustration 3 | g01294214 |
- Remove Tooling (A) (not shown) from clean gas induction cooler (8) .
- Remove Tooling (B) (not shown) from clean gas induction cooler (8) .
- Install tube assembly (5) .
Illustration 4 | g01294180 |
- Connect hose (4) . Tighten the clamp to a torque of 11 ± 7 N·m (97 ± 62 lb in).
- Connect tube (3) and Install bolt (2) .
- Apply Tooling (C) to the threads of clamp (1) and connect clamp (1) . Tighten clamp (1) to torque of 12 ± 4 N·m (106 ± 35 lb in).