Usage:
The personality module (1) is mounted on the Electronic Locomotive Control Box.
ELECTRONIC LOCOMOTIVE CONTROL BOX
(1) Personality Module. (2) Threaded Holes.
1. Remove four bolts from personality module (1).
2. Install two of the bolts removed into threaded holes (2) of the personality module. Tighten these bolts until the module can be removed.
3. Carefully clean all sealing material from the flange on the personality module and the surface of the control both.
4. Apply 6V6640 Liquid Gasket on the flange of the personality module.
5. Use two bolts at opposite corners as guide bolts. This will help align the connector and avoid smearing the sealant.
6. Tighten the guide bolts and install and tighten the remaining two bolts.
7. Low idle trim, and wheel slip up and wheel slip down ramp rates may have to be reset before this system is ready for use. See Service Procedures E and F.
PERSONALITY MODULE REMOVED