Camshaft Position Sensor - Remove and Install
Show/hide table
Required Tools | |||
Tool | Part Number | Description | Qty |
A | 207-1601 | Rubber Lubricant | 1 |
- Disconnect the harness assembly and remove bolt (1). Remove camshaft position sensor (2) and the O-ring seal.
Show/hide table
Illustration 1 | g02106354 |
- Install the camshaft position sensor (2) in the reverse order of removal.
- Apply Tooling (A) to the O-ring seal prior to the installation of camshaft position sensor (2).
Caterpillar Information System:
C12.9 Marine Engines Aftercooler - Remove and Install - High-Pressure
XQP150 Rental Generator Set Control Panel
3512E Engines Housing (Front) - Remove and Install
C7.1 Industrial Engine Flywheel Housing - Remove and Install
C18 Generator Set Engines Atmospheric Pressure Sensor - Remove and Install
XQP150 Rental Generator Set Fuel System - Prime
XQP150 Rental Generator Set Hoses and Clamps - Inspect/Replace
C18 Generator Set Engines Nitrogen Oxide Sensor - Remove and Install
New Engine Software Is Now Available For Certain C18 630 hp Industrial Engines {1920} New Engine Software Is Now Available For Certain C18 630 hp Industrial Engines {1920}
XQP150 Rental Generator Set Radiator - Clean
XQP150 Rental Generator Set Engine Oil Sample - Obtain
C18 Generator Set Engines Bearing Clearance - Check
C175 Tier 4 Final Engines for Off-Highway Trucks Coolant Pressure Is Low
XQP150 Rental Generator Set Generator Lead Connections
Bench Test Procedure For A TA22 Construction Transmission {0374, 0599, 3030, 3065, 3139, 3167, 3182} Bench Test Procedure For A TA22 Construction Transmission {0374, 0599, 3030, 3065, 3139, 3167, 3182}
G3512 Generator Set Product Description
A New Turbocharger Is Now Used On Certain 3516C Engines {1052, 1053} A New Turbocharger Is Now Used On Certain 3516C Engines {1052, 1053}
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Plate Locations and Film Locations
C18 Generator Set Engines Crankshaft Position Sensor - Remove and Install
C18 Generator Set Engines Coolant Temperature Sender - Remove and Install
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Emissions Certification Film
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Reference Information
G3512 EPA Emergency and Non-Emergency Standby Generator Sets Product Lifting
XQP150 Rental Generator Set Setup