Assembly Procedure
Note: Cleanliness is an important factor. Before assembly, thoroughly clean all parts in cleaning fluid. Allow the parts to air dry. Do not use wiping cloths or rags to dry parts. Lint may be deposited on the parts which may cause trouble. Inspect all parts. If any parts are worn or damaged, use new parts for replacement. Dirt and other contaminants can damage the precision component. Perform assembly procedures on a clean work surface. Keep components covered and protected at all times.
Note: Check the O-ring seals, the gaskets, and the seals for wear or for damage. Replace the components, if necessary.
- Install O-ring seals (14) and (9) to the body. Install O-ring seal (11) to plug (8) . Install plug (8) .
Improper assembly of parts that are spring loaded can cause bodily injury. To prevent possible injury, follow the established assembly procedure and wear protective equipment. |
Illustration 1 | g00819456 |
Illustration 2 | g00819409 |
- Install spool (13) . Install spring (12) . Install spring (10) , if necessary.
Note: Spring (10) is not required on all valve assemblies.
- Place cover (6) , and bracket (7) in position and install bolts (5) .
- Install plate (3) with bolts (4) .
Illustration 3 | g00819408 |
- Install temperature sensor (1) to body (2) of the torque converter outlet relief valve.
Illustration 4 | g00819395 |
End By: Install the torque converter outlet relief valve. Refer to Disassembly and Assembly, "Torque Converter Outlet Relief Valve - Install".