D346, D348 & D349 VEHICULAR ENGINES Caterpillar


Every 500 Service Meter Units or 3 Months

Usage:

(9)Fan Bearing

Lubricate 1 fitting.

(10)Cooling System-Add Corrosion Inhibitor

------ WARNING! ------

Always inspect the cooling system with the engine stopped.

Inhibitor contains alkali, avoid contact with skin and eyes to prevent personal injury.

Remove filler cap slowly to relieve pressure. Steam can cause personal injury.

------WARNING!--------

First 500 SERVICE HOURS OR 3 MONTHS on a new or reconditioned engine: Add enough Caterpillar Corrosion Inhibitor, 1 pint (.50 liter) per 4 gallons (15.14 liters) of cooling system capacity, or equivalent, so that the cooling system will have a 3% concentration of inhibitor.

EVERY 500 SERVICE HOURS OR 3 MONTHS thereafter: Add 1 pint (.50 liters) of Caterpillar Corrosion Inhibitor, or equivalent, per 16 gallons (60.57 liters) of cooling system capacity. This will maintain the required 3% concentration of inhibitor.


NOTICE

Do not use Caterpillar Corrosion Inhibitor with Dowtherm 209 Coolant.


1. Loosen the radiator cap slowly to relieve pressure, and remove cap.

It may be necessary, to drain enough coolant to allow for the addition of corrosion inhibitor.

2. Add the correct amount of Caterpillar Corrosion Inhibitor, or equivalent.
3. Inspect the filler cap gasket. Use a new cap if the used one is damaged.
4. Install the radiator filler cap.
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.