Usage:
Fluid Spillage Containment
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to "Tools And Shop Products Guide", NENG2500 for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose fluids according to local regulations and mandates.
1. Remove hose (1). Allow washer fluid to drain from the tank into an acceptable container for reuse or disposal prior to proceeding.
2. Disconnect wiring connector (2).
3. Remove washer pump (3).
NOTE: Washer pumps "snap" into correct position. There are no fasteners required.
4. Remove hose (4). Disconnect wire connector (5) and remove washer pump (6).
NOTE: Install in reverse order.