System information displays the Machine Model, product ID, Software P/N, OS version used, SW Release date, ECM serial number, and Hardware P/N on that particular device. This section gives an idea about the current software used in the display used for informational purpose only.
Illustration 1 | g03648038 |
Settings Screen
The Settings section is being used to configure the object detection system settings such as Alarm mode, Detect Standby, and Delay Time according to the requirements. These can only be changed while the machine is in Neutral gear.
The "OK" button to be pressed for applying all the settings. The back button is pressed without pressing "OK" then the earlier setting shall remain.
Illustration 2 | g03530816 |
Object Detection Alarm Mode
Illustration 3 | g03530856 |
The "Object Detection Alarm Mode" parameter configures the audible alarm mode. The alarm mode will be "Continuous" by default. "Discrete" alarming can be selected to reduce the length of audible alarming.
Note: This parameter is only adjustable when the Cat ® Electronic Technician is connected and communicating with the system.
The operator tries to change the mode without connecting the ET the following pop-up will occur. The operator should acknowledge the popup before moving on to any other screen.
Illustration 4 | g03530896 |
Object Detection Standby Mode
Note: This parameter is only adjustable when Cat ® Electronic Technician (Cat ET) is connected and communicating with the system.
The system can be configured to run in one of two different modes:
Distance - In "Distance" based standby, once the machine travels 20 m (66 ft) the system goes into standby mode. When the machine stops for "x" seconds the system returns to active mode. The "x" seconds are set in the "Object Detection System Enable Delay" dialog. This delay can be set from 0 to 30 seconds
Speed - In "Speed" based standby, once the machine travels above 11 km/h (7 mph) the system enters standby mode. When the machine slows down to below 4.8 km/h (3.0 mph) the system returns to active mode.
Illustration 5 | g03530936 |
The operator tries to change the mode without connecting the ET the following pop-up will occur. The operator should acknowledge the popup before moving on to any other screen.
Illustration 6 | g03530937 |
Object Detection Standby Enable Mode
Note: This parameter is only adjustable when Caterpillar Electronic Technician (Cat ET) is connected and communicating with the system.
This parameter configures the delay time that will be used by the object detection system to delay the activation of the object detection system after the machine comes to a stop. Press the +/- buttons to adjust the delay time.
When the machine stops for "X" seconds the system returns to active mode. This delay can be set from 0 to 30 seconds.
Illustration 7 | g03530978 |
Once the operator has changed all the desired settings, pressing the "OK"button apply the new settings to the system.
The operator tries to change the mode without connecting the ET the following pop-up will occur. The operator should acknowledge the popup before moving on to any other screen.
Illustration 8 | g03530980 |