Usage:
Typical Illustration
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed (min) ... 6800 rpm
Current (max) ... 155 A
Voltage ... 23 V
(1) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Ground terminal. Tighten to a torque of ... 30.5 ± 3.5 N·m (270 ±31 lb in)
(3) Switch terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Motor frame terminal. Tighten terminal to a torque of ... 25 ± 7 N·m (221 ± 62 lb in)
(5) Motor terminal. Tighten terminal to a torque of ... 30.5 ± 3.5 N·m 270 ± 31 lb in)
Solenoid:
Current consumption (draw):
Pull-in current at 24 V ... 64 A
Hold-in current at 24 V ... 10 A
Typical Illustration
Typical Illustration
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed (min) ... 5501 rpm
Speed (max) ... 8535 rpm
Current (min) ... 100 A
Current (max) ... 155 A
Voltage ... 11 V
(1) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Motor frame terminal. Tighten terminal to a torque of ... 8 ± 3 N·m (71 ± 27 lb in)
(3) Switch terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Motor terminal. Tighten terminal to a torque of ... 8 ± 3 N·m (71 ± 27 lb in)
(5) Ground terminal. Tighten to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
Solenoid:
Current consumption (draw):
Pull-in current at 12 V ... 84 to 94 A
Hold-in current at 12 V ... 21 to 25 A
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed (min) ... 3215 rpm
Speed (max) ... 4041 rpm
Current (min) ... 68 A
Current (max) ... 100 A
Voltage ... 23 V
(1) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Motor frame terminal. Tighten terminal to a torque of ... 8 ± 3 N·m (71 ± 27 lb in)
(3) Switch terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Motor terminal. Tighten terminal to a torque of ... 14.7 ± 3.4 N·m (130 ± 30 lb in)
(5) Ground terminal. Tighten to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
Solenoid:
Current consumption (draw):
Pull-in current at 20 V ... 34 to 38 A
Hold-in current at 20 V ... 6.75 A
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed (min) ... 7200 rpm
Speed (max) ... 9700 rpm
Current (min) ... 50 A
Current (max) ... 80 A
Voltage ... 23 V
(1) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(3) Switch terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Motor terminal. Tighten terminal to a torque of ... 14.7 ± 3.4 N·m (130 ± 30 lb in)
(5) Ground terminal. Tighten to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
Solenoid:
Current consumption (draw):
Pull-in current at 20 V ... 52 to 61 A
Hold-in current at 20 V ... 14.6 A
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed (min) ... 5970 rpm
Speed (max) ... 9326 rpm
Current (min) ... 60 A
Current (max) ... 75 A
Voltage ... 23 V
(1) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Motor frame terminal. Tighten terminal to a torque of ... 8 ± 3 N·m (71 ± 27 lb in)
(3) Switch terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Motor terminal. Tighten terminal to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(5) Ground terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Solenoid:
Current consumption (draw):
Pull-in current at 20 V ... 52 to 61 A
Hold-in current at 20 V ... 14.6 A
Typical Illustration
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed (min) ... 3800 rpm
Current (max) ... 120 A
Voltage ... 24 V
(1) Ground terminal. Tighten to a torque of ... 26 ± 3.5 N·m (230 ± 31 lb in)
(2) Motor terminal. Tighten terminal to a torque of ... 25 ± 7 N·m (221 ± 62 lb in)
(3) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 26 ± 3.5 N·m (230 ± 31 lb in)
(4) Switch terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Solenoid:
Current consumption (draw):
Pull-in current at 24 V ... 50 A
Hold-in current at 24 V ... 20 A
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed (min) ... 4200 rpm
Current (max) ... 220 A
Voltage ... 12 V
(1) Ground terminal. Tighten to a torque of ... 26 ± 3.5 N·m (230 ± 31 lb in)
(2) Motor terminal. Tighten terminal to a torque of ... 25 ± 3.5 N·m (230 ± 31 lb in)
(3) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 26 ± 3.5 N·m (230 ± 31 lb in)
(4) Switch terminal. Tighten to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Solenoid:
Current consumption (draw):
Pull-in current at 12 V ... 90 A
Hold-in current at 12 V ... 30 A