SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Caterpillar


Contactor Group Low Pressure Oil Switch Assembly

Usage:


Low Pressure Oil Switch Assembly (Left Side View)

(1) Seal

(2) Low Pressure Oil Switch Assembly. Tighten to a torque of ... 40 ± 5 N·m (30 ± 4 lb ft)

6T6652

Terminal No. 1 is common.

Terminal No. 2 is normally open.

Terminal No. 3 is normally closed.

With pressure increase, terminal 2 closes and terminal 3 opens at ... 158 ± 28 kPa (23 ± 4 psi)

With pressure decrease, terminal 2 opens and terminal 3 closes at ... 124 ± 21 kPa (18 ± 3 psi)

9X4276

Terminal No. 1 is common.

Terminal No. 2 is normally open.

Terminal No. 3 is normally closed.

With pressure increase, terminal 2 closes and terminal 3 opens at ... 93 ± 21 kPa (14 ± 3 psi)

With pressure decrease, terminal 2 opens and terminal 3 closes at ... 69 ± 21 kPa (10 ± 3 psi)

High Water Temperature Contactor Assembly


High Water Temperature Contactor Assembly (Rear View)

(1) High Water Temperature Contactor Assembly. Tighten to a torque of ... 75 ± 7 N·m (55 ± 5 lb ft)

(2) Seal

Terminal No. 1 is normally open.

Terminal No. 2 is common.

Terminal No. 3 is normally closed.

7E8342

With temperature increase, terminal 2 closes and terminal 3 opens at ... 102 ± 2°C (216 ± 3°F)

With temperature decrease, terminal 2 opens and terminal 3 closes at ... 95°C (203°F)

7E8343

With temperature increase, terminal 2 closes and terminal 3 opens at ... 107 ± 1.5°C (225 ± 3°F)

With temperature decrease, terminal 2 opens and terminal 3 closes at ... 100°C (212°F)

9Y1207

With temperature increase, terminal 2 closes and terminal 3 opens at ... 92 ± 1.5°C (198 ± 3°F)

With temperature decrease, terminal 2 opens and terminal 3 closes at ... 85°C (185°F)

9Y1208

With temperature increase, terminal 2 closes and terminal 3 opens at ... 98 ± 1.5°C (208 ± 3°F)

With temperature decrease, terminal 2 opens and terminal 3 closes at ... 91°C (196°F)

9Y3871

Terminal No. 1 is normally open.

Terminal No. 2 is common.

Terminal No. 3 is normally closed.

With temperature increase, terminal 2 closes and terminal 3 opens at ... 113 ± 1°C (235 ± 2°F)

With temperature decrease, terminal 2 opens and terminal 3 closes at ... 106°C (222°F)

Caterpillar Information System:

SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Air Compressor
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Exhaust Extension
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Exhaust Pipe Group
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Exhaust Elbow
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Muffler Group
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Fan Drive
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Rear Stub Shaft
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Air Inlet Heater
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Aftercooler Group
3208 INDUSTRIAL ENGINE ATTACHMENTS Testing & Adjusting
3208 INDUSTRIAL ENGINE ATTACHMENTS Systems Operation
3208 INDUSTRIAL ENGINE ATTACHMENTS Fan Mounting Pulley Assemblies
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Sender Group
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Instrument Panel Group
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Voltmeter
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Service Meter
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Tachometer (Digital)
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Junction Box
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Start Switch
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Vernier Control Cable Assembly
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Alternator and Regulator
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Starting Motor
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Systems Operation
SUPPLEMENT FOR 3114, 3116 & 3126 - INDUSTRIAL ENGINES ENGINES EQUIPPED WIT Testing And Adjusting
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.