3408C & 3412C INDUSTRIAL ENGINES Caterpillar


Switches

Usage:

Liquid Level

NOTE: Switch shown in high level position.

(1) Approximate liquid level when switch activitates ... 6.4 mm (.25 in)

Contact position is normally closed.

Temperature

2W8915

Terminal No. 1 is normally open below actuation temperature.

Terminal No. 2 is common.

Terminal No. 3 is normally closed below actuation temperature.

With a temperature increase of 98 ± 1.5°C (208 ± 2°F), terminal No. 1 closes and terminal No. 3 opens.

With a temperature increase of 91°C (196°F), terminal No. 1 opens and terminal No. 3 closes.

(1) Final torque for switch assembly ... 52 ± N·m (38 ± 6 lb ft)

7C9365

Terminal No. 1 is normally open below actuation temperature.

Terminal No. 2 is common.

Terminal No. 3 is normally closed below actuation temperature.

With a temperature increase of 107 ± 1.5°C (225 ± 2°F), terminal No. 1 closes and terminal No. 3 opens.

With a temperature increase of 100°C (212°F), terminal No. 1 opens and terminal No. 3 closes.

(1) Final torque for switch assembly ... 52 ± 8 N·m (38 ± 6 lb ft)

5N8857

Terminal A is normally open below actuation temperature.

Terminal B is common.

Terminal C is normally closed below actuation temperature.

With a temperature increase of 98 ± 1.5°C (208 ± 2°F), terminal A closes and terminal C opens.

With a temperature decrease of 91°C (196°F), terminal A opens and terminal C closes.

(1) Final torque for switch assembly ... 52 ± 8 N·m (38 ± 6 lb ft)

2W8916

Terminal A is normally open below actuation temperature.

Terminal B is common.

Terminal C is normally closed below actuation temperature.

With a temperature increase of 92 ± 1.5°C (198 ± 2°F), terminal A closes and terminal C opens.

With a temperature decrease of 85°C (185°F), terminal No. A opens and terminal C closes.

(1) Final torque for switch assembly ... 52 ± 8 N·m (38 ± 6 lb ft)

3N7442

Low Water Temperature Switch

Switch must open between ... 24 and 29°C (75 and 84°F)

Switch must close between ... 18 and 24°C (64 and 75°F)

8N1693 For Ether Aid

Switch must open between ... 35 and 41°C (95 and 106°F)

Switch must close ... 27°C (81°F min)

Final installation tighten screws to a torque of ... 1.7 ± 0.2 N·m (15 ± 2 lb in)

Final torque for switch assembly ... 40 ± 5 N·m (29 ± 4 lb ft)

Pressure

6T6652

When installing switch, tighten to a maximum of ... 40 ± 5 N·m (29 ± 4 lb ft)

Terminal No. 1 is common.

Terminal No. 2 is normally open below 103 kPa (15 psi).

Terminal No. 3 is normally closed below 103 kPa (15 psi).

With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 158 ± 28 kPa (23 ± 4 psi)

With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 124 ± 21 kPa (18 ± 3 psi)

Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)

9X4276

When installing switch, tighten to a maximum of ... 40 ± 5 N·m (29 ± 4 lb ft)

Terminal No. 1 is common.

Terminal No. 2 is normally open below 48 kPa (7 psi).

Terminal No. 3 is normally closed below 48 kPa (7 psi).

With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 93.0 ± 20.8 kPa (13.5 ± 3.0 psi)

With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 68.9 ± 20.8 kPa (10.0 ± 3.0 psi)

Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)

2L3402

Current rating:

24 volts DC ... 4A

32 volts DC ... 2A

With an increase in pressure, switch closes at ... 20.7 to 27.6 kPa (3 to 4 psi)

7N5946, For use with time delay and shutdown systems

Circuit 1: normally closed

Circuit 2: normally open

With an increase in pressure, circuit 1 opens and circuit 2 closes at ... 145 kPa (21 psi) max.

With a decrease in pressure, circuit 2 opens and circuit 1 closes at ... 75 ± 20 kPa (11 ± 3 psi)

3N7443, Alarm or Shutoff

With an increase of pressure, switch operates at ... 130 to 145 kPa (19 to 21 psi)

With a decrease of pressure, switch operates at ... 105 to 110 kPa (15 to 16 psi)

Starter Magnetic

Pull in voltage a 25° C ... 17 V

Current consumption (draw) both windings at 24V ... 0.82 ± 0.06 A

Type duty ... Intermittent

(1) Torque for large terminal nuts ... 3.6 ± 0.4 N·m (31 ± 4 lb in)

(2) Torque for small terminal nuts ... 1.7 ± 0.3 N·m (15 ± 3 lb in)