Usage:
4W0510
2W3687
NOTE: Pointer movement beyond point A of indicator band not permitted.
NOTE: Pointer must stop within +0.0 -2.0 mm (+.00 -.08 in) of point C.
Water Temperature
1W0700, 2W0417
4W2683
7W2061 Indicator 12V; Use with 5L7443 Sending Unit
Range ... 38 to 116°C (100 to 240°F)
Test voltage ... 13.8 ± 0.3V
Tolerance ... ±0.76 mm (.03 in)
NOTE: Measure tolerance from the end of the pointer to the centerline of the mark on the face of the indicator.
7W2060 Indicator 24-32V; Use with 5L7442 Sending Unit
Range ... 38 to 116°C (100 to 240°F)
Test voltage ... 27.2 ± 0.3V
Tolerance ... ±0.76 mm (.03 in)
NOTE: Measure tolerance from the end of the pointer to the centerline of the mark on the face of the indicator.
NOTE: For 32V systems the 5L7441 resistor (65 ohms) is used with this indicator.
Oil Pressure
2W3681 (Mechanical)
NOTE: Calibrating hole in dial face.
4W0506
7W2936 Indicator 12V; Use with 9X1124 Sending Unit
Range ... 0 to 550 kPa (0 to 80 psi)
Test voltage ... 13.8 ± 0.3V
Tolerance ... ±0.8 mm (.03 in)
NOTE: Measure tolerance from the end of the pointer to the centerline of the mark on the face of the indicator.
7W2937 Indicator 24-32V; Use with 9X1124 Sending Unit
Range ... 0 to 550 kPa (0 to 80 psi)
Test voltage ... 27.2 ± 0.3V
Tolerance ... ±0.8 mm (.03 in)
NOTE: Measure tolerance from the end of the pointer to the centerline of the mark on the face of the indicator.
NOTE: For 32V systems the 5L7441 resistor (65 ohms) is used with this indicator.
Differential Pressure
4W0508