Remote Filters
Illustration 1 | g02789385 |
Power Take-Off and Without Power Take-Off Configuration |
Note: Lubricate all bores and O-ring seals with lubricant before installing the O-ring seals.
(1) Torque for bolts ... 28 ± 7 N·m (21 ± 5.2 lb ft)
(2) Torque for two O-ring plugs ... 74 ± 4 N·m (55 ± 3 lb ft)
(3) Pressure switch
- Torque for pressure switch ... 12 ± 3 N·m (8.9 ± 2.2 lb ft)
- Actuation pressure at 21° ± 3°C (70° ± 5°F) ... 435 ± 41 kPa (63 ± 6 psi)
- Actuation pressure at 100° ± 3°C (212° ± 5°F) ... 380 ± 28 kPa (55 ± 4 psi)
- Minimum deactuation pressure at −40° to +121°C (−40° to +250°F) ... 275 kPa (40 psi)
- Operating temperature ... −40° to +121°C (−40° to +250°F)
- Actuation pressure at 21° ± 3°C (70° ± 5°F) ... 435 ± 41 kPa (63 ± 6 psi)
(4) Torque for plug ... 38 ± 2 N·m (28 ± 1.5 lb ft)
Cartridge-Type Filters
Illustration 2 | g01523174 |
Power Take-Off |
Illustration 3 | g01523214 |
Without Power Take-Off Configuration |
Note: Lubricate all bores and O-ring seals with lubricant before installing the O-ring seals.
Note: Do not use an air wrench on the filter.
(1) Torque for two O-ring plugs ... 74 ± 4 N·m (55 ± 3 lb ft)
(2) Pressure switch
- Torque for pressure switch ... 12 ± 3 N·m (8.9 ± 2.2 lb ft)
- Actuation pressure at 21° ± 3°C (70° ± 5°F) ... 435 ± 41 kPa (63 ± 6 psi)
- Actuation pressure at 100° ± 3°C (212° ± 5°F) ... 380 ± 28 kPa (55 ± 4 psi)
- Deactuation pressure at −40° to +121°C (−40° to +250°F) ... 275 kPa (40 psi)
- Operating temperature ... −40° to +121°C (−40° to +250°F)
- Actuation pressure at 21° ± 3°C (70° ± 5°F) ... 435 ± 41 kPa (63 ± 6 psi)
(3) Torque for filter ... 55 ± 10 N·m (41 ± 7.4 lb ft)
Spin-On Filters
Illustration 4 | g01523173 |
Power Take-Off |
Illustration 5 | g01523215 |
Without Power Take-Off Configuration |
Note: Lubricate all bores and O-ring seals with lubricant before installing the O-ring seals.
Note: Do not use an air wrench on the filter. Use 185-3630 Strap Wrench As to torque the filter.
(1) Torque for two O-ring plugs ... 74 ± 4 N·m (55 ± 3 lb ft)
(2) Pressure switch
- Torque for pressure switch ... 12 ± 3 N·m (8.9 ± 2.2 lb ft)
- Actuation pressure at 21° ± 3°C (70° ± 5°F) ... 435 ± 41 kPa (63 ± 6 psi)
- Actuation pressure at 100° ± 3°C (212° ± 5°F) ... 380 ± 28 kPa (55 ± 4 psi)
- Deactuation pressure at −40° to +121°C (−40° to +250°F) ... 275 kPa (40 psi)
- Operating temperature ... −40° to +121°C (−40° to +250°F)
- Actuation pressure at 21° ± 3°C (70° ± 5°F) ... 435 ± 41 kPa (63 ± 6 psi)
(4) Torque for filter ... 70 ± 7 N·m (52 ± 5 lb ft)
Illustration 6 | g01623748 |
View A-A |
(5) Apply 155-0695 Thread Lock Compound to the threads of the filter base stud and install the filter base stud into the filter base. Torque for filter base stud ... 100 ± 20 N·m (74 ± 15 lb ft)
(A) Make sure that 24 ± 1.5 mm (0.95 ± 0.06 inch) of the filter base stud extends past the outside edge of the filter housing.