Introduction
The diverter flow valves will divert flow from the inside wheel to the outside wheel in order to allow the outside wheel to turn faster than the inside wheel. Diverting the flow greatly reduce tire scrubbing and allows for optimal turning.
Note: Prior to performing this test, the Testing and Adjusting, "Hydraulic System Pressure - Test and Adjust" must be performed.
Machine Preparation
- Clear all personnel from the machine and from the area around the machine.
- Start the engine.
NOTICE |
---|
To avoid system damage, make sure that the hydraulic pump is properly filled with hydraulic oil before start-up. |
- Place the hydraulic activation control lever in the UNLOCKED position.
- Press button "A" on the monitor to set the engine speed at "Max Speed".
Illustration 1 | g03095556 |
Engine speed control "Max Speed" as displayed on the programmable function key on the monitor. |
- Push down on the parking brake control button in order to de-activate the parking brake.
Note: The green indicator light will be illuminated when the parking brake is de-activated.
Illustration 2 | g03094559 |
Parking brake control button located on the soft panel switch |
- Push down on the swing brake control button in order to de-activate the swing brake.
Note: The green indicator light will be illuminated when the swing brake is de-activated.
Illustration 3 | g03094697 |
Swing brake control button located on the soft panel switch |
- Position the machine on level ground. Check the visibility and adjust the mirrors for the best vision close to the machine.
- Push down on the stabilizer control button in order to lower the stabilizer to the ground.
Illustration 4 | g03094816 |
Stabilizer lower control button located on the soft panel switch |
- Lower the work tool to the ground.
- Place the hydraulic activation control lever in the LOCKED position.
- Stop the engine.
Adjustment Procedure
- Loosen the locknut on diverter flow valve (1) and turn the adjustment screw all of the way to the stop.
Illustration 5 | g03229617 |
View of diverter flow valves (1) Right front (reverse) (2) Left front (reverse) (3) Left rear (reverse) (4) Right rear (reverse) (5) Right front (forward) (6) Left front (forward) (7) Left rear (forward) (8) Right rear (forward) |
- Back the adjustment screw out four turns.
- Turn in adjustment screw by one half turn.
- While the adjustment screw for the diverter flow valve is being held, tighten the locknut.
- Repeat the adjustment procedures for the other seven diverter flow valves.