Usage:
8C3643 (12V), 6V3969 (12V)
Rotation as viewed from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 6900 ± 1800 rpm
Current draw ... 127.5 ± 27.5A
Voltage ... 11V
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Torque for small terminal nuts ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(3) Torque for motor frame terminal ... 8 ± 3 N·m (70 ± 26 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 10V ... 92.5 ± 7.5A
Hold in windings at 10V ... 23A
9G4339 (24V), 6V4458 (24V), 6V5537 (24V)
Rotation as viewed from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 7643 ± 1683 rpm
Current draw ... 67.5 ± 7.5A
Voltage ... 23V
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Torque for small terminal nuts ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(3) Torque for motor frame terminal ... 8 ± 3 N·m (70 ± 26 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 20V ... 56.5 ± 4.5A
Hold in windings at 20V ... 14.6A
6V3954 (12V)
Rotation as viewed from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 5500 rpm max
Current draw ... 200A max
Voltage ... 12V
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Torque for small terminal nuts ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 12V ... 92A
Hold in windings at 12V ... 16A
6V4454 (24), 106-8552 (24V)
Rotation as viewed from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 5500 rpm min
Current draw ... 140A max
Voltage ... 24V
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Torque for small terminal nuts ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 24V ... 51A
Hold in windings at 24V ... 7A
122-6032
Rotation as seen from drive end ... Clockwise
No load conditions:
Speed (rpm) ... 3300 Minimum
Current (amps) ... 130 Maximum
Voltage ... 11.5V
(1) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Nut. Tighten nut to a torque of ... 1.5 ± 0.5 N·m (13 ± 4 lb in)
(3) Ground terminal. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(4) Switch terminal. Tighten nut to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Motor terminal. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(6) Motor frame terminal. Tighten nut to a torque of ... 17.5 ± 2.5 N·m (155 ± 22 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 12V ... 160A
Hold in windings at 12V ... 90A
6V5538
Rotation as seen from drive end ... Clockwise
No load conditions:
Speed (rpm) ... 3300 Minimum
Current (amps) ... 80 Maximum
Voltage ... 23.5V
(1) Battery terminal. Three cables or wire terminal maximum between nuts. Two cable terminals maximum with 0 AWG or larger. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(2) Nut. Tighten nut to a torque of ... 1.5 ± 0.5 N·m (13 ± 4 lb in)
(3) Ground terminal. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(4) Switch terminal. Tighten nut to a torque of ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Motor terminal. Tighten nut to a torque of ... 30.5 ± 3.5 N·m (270 ± 31 lb in)
(6) Motor frame terminal. Tighten nut to a torque of ... 17.5 ± 2.5 N·m (155 ± 22 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 24V ... 103A
Hold in windings at 24V ... 19A