Usage:
NOTE: This Containment Program can only be administered after a failure occurs. The decision whether to apply the Program is made by the dealer. When reporting the repair, use "PS20013" as the Part number and "7755" as the Group Number. Use "96" as the Warranty Claim Description Code and use "Z" as the SIMS Description Code.
Termination Date
May 31, 2002Problem
The solenoids for the implement control valve fail on certain 554 and 574 Forwarders and 550, 570 and 580 Harvesters. The solenoids fail due to moisture entering through the top of the solenoids at the wiring harness connection point.
Affected Product
Model & Identification Number
580 (7CN1-Up)
550 (7ZN1-Up)
570 (4XR1-Up)
574 (1FM1-Up)
554 (1AM1-Up)
Parts Needed
- 1 - 1712448 Valve Group - Solenoid
Action Required
1. Remove the failed solenoid.
2. Remove the orifice from the bottom of the failed solenoid and install it into the new 1712448 Solenoid.
3. Install the new solenoid.
NOTE: Do not wash the machine in the area of thesolenoids.Washing near the solenoids causes moisture to enter the solenoid resulting in premature solenoid failures.
Service Claim Allowances
Parts Disposition
Handle the parts in accordance with your Warranty Bulletin on warranty parts handling.