Type 1
Illustration 1 | g00286672 |
Illustration 2 | g00286673 |
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 6900 ± 1800 rpm
- Current draw ... 127.5 ± 27.5 amp
- Voltage ... 11 V
- Current draw ... 127.5 ± 27.5 amp
(1) Tighten the nut on the battery terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (70.8 ± 26.6 lb in)
3E-5449 Starting Motor Solenoid Assembly
Current consumption at 25°C (77°F)
- Pull-in windings at 10V ... 92.5 ± 7.5 Amp
- Hold-in windings at 10V ... 23 Amp
Type 2
Illustration 3 | g00286676 |
Illustration 4 | g00286677 |
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 5500 rpm minimum
- Current draw ... 140 Amp maximum
- Voltage ... 24 V
- Current draw ... 140 Amp maximum
(1) Tighten the nut on the ground terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(2) Tighten the nut on the battery terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
9X-0332 Solenoid Kit
Current consumption at 25°C (77°F)
- Pull-in windings at 24V ... 51 Amp
- Hold-in windings at 24V ... 7 Amp
Type 3
Illustration 5 | g00286672 |
Illustration 6 | g00286673 |
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 7643 ± 1683 rpm
- Current draw ... 76.5 ± 7.5 amp
- Voltage ... 23 V
- Current draw ... 76.5 ± 7.5 amp
(1) Tighten the nut on the battery terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (70.8 ± 26.6 lb in)
9X-9511 Solenoid Assembly
Current consumption at 25°C (77°F)
- Pull-in windings at 20V ... 56.5 ± 4.5 Amp
- Hold-in windings at 20V ... 14.6 Amp
Type 4
Illustration 7 | g00916190 |
Illustration 8 | g00916414 |
When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25°C (77°F)
- Speed ... 6950 ± 1650 rpm
- Current draw ... 115 ± 25 amp
- Voltage ... 23 V
- Current draw ... 115 ± 25 amp
(1) Tighten the nut on the battery terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(2) Tighten the nut on the ground terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (19.914 ± 2.213 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 30 ± 3.5 N·m (22.1 ± 2.58 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (70.8 ± 26.6 lb in)
125-6533 Solenoid Assembly
Current consumption at 25°C (77°F)
- Pull-in windings at 20V ... 49.3 ± 3.3 Amp
- Hold-in windings at 20V ... 6.8 Amp