Removal Procedure
Show/hide table
|
NOTICE |
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. |
|
Note: Put identification marks on all hoses, on all hose assemblies, on all wires, and on all tube assemblies for installation purposes. Plug all hose assemblies and all tube assemblies. This helps to prevent fluid loss, and this helps to keep contaminants from entering the system.
- Drain the coolant into a suitable container for storage or disposal. Refer to Operation and Maintenance Manual, "Cooling System Coolant (ELC) - Change".
Show/hide table
|
|
|
Illustration 1 | g01156851 |
- Remove bolts (1) and belt guard (2) .
Show/hide table
|
|
|
Illustration 2 | g01156853 |
- Remove belt (3) .
Show/hide table
|
|
|
Illustration 3 | g01160563 |
- Remove hose (4) and tube (5) .
Show/hide table
|
|
|
Illustration 4 | g01160572 |
- Remove bolts (7) and guard assembly (6) .
Show/hide table
|
|
|
Illustration 5 | g01160585 |
- Disconnect tube assembly (8) and hose (9). Remove bolts (10) and housing (11). Remove tube (12) .
Show/hide table
|
|
|
Illustration 6 | g01160593 |
- Remove bolt (14) and pulley (13) .
Show/hide table
|
|
|
Illustration 7 | g01160596 |
- Remove bolts (17). Loosen clamps (15). Remove adapter (16) .
Show/hide table
|
|
|
Illustration 8 | g01160601 |
- Disconnect hose (20). Remove bolts (19). Remove elbow (18) .
Show/hide table
|
|
|
Illustration 9 | g01160642 |
- Remove bolts (22) and water pump (21) .