Winding Data for 144-1964 Generator through 144-2088 Generator
144-1964 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 450.850 mm (17.75 inch)     |
463.550 mm (18.25 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-13     | 1-2     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 12 - 2.4892 mm (0.098 inch) x 4.2672 mm (0.168 inch) 2 Wide x 6 High     |
#6 Square     | |||||
Mean Length Turn     | 1859.28 mm (73.2 inch)     |
1463.04 mm (57.6 inch)     |
|||||
Copper Weight     | 149.6 kg (330 lb)     |
187.7 kg (414 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     |     | |||||
Line Leads (No. & Size)     | 6-4 of #000 (24 Total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00385 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.389 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1968 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 508.0 mm (20 inch)     |
520.70 mm (20.5 inch)     |
|||||
Slots     | 60     | 4     | |||||
Coil Throw     | 1-11     | 1-2     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 10 - 3.0226 mm (0.119 inch) x 4.2926 mm (0.169 inch) 2 WIDE x 5 HIGH     |
#6 Square Heavy Film     | |||||
Mean Length Turn     | 1813.56 mm (71.4 inch)     |
1584.96 mm (62.4 inch)     |
|||||
Copper Weight     | 123.3 kg (272 lb)     |
215.4 kg (475 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     |     | |||||
Line Leads (No. & Size)     | 6 - 4 of # 4/0     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00334 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.488 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1974 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 368.30 mm (14.5 inch)     |
381.0 mm (15 inch)     |
|||||
Slots     | 84     | 4     | |||||
Coil Throw     | 1-15     | 1-2     | |||||
Turns/Coil     | 5     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 1 of 2.5908 mm (0.102 inch) x 5.0546 mm (0.199 inch) 1 Wide x 1 High     |
#6 Square     | |||||
Mean Length Turn     | 1694.18 mm (66.7 inch)     |
1298.702 mm (51.13 inch)     |
|||||
Copper Weight     | 86.1 kg (190 lb)     |
166.64 kg (367.4 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #4 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.706 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.27 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1976 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 381.0 mm (15 inch)     |
393.70 mm (15.5 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-13     | 1-2     | |||||
Turns/Coil     | 5     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 1 of 2.0574 mm (0.081 inch) x 7.3406 mm (0.289 inch)     |
1 of #6 square     | |||||
Mean Length Turn     | 1656.08 mm (65.2 inch)     |
1330.96 mm (52.4 inch)     |
|||||
Copper Weight     | 169.82 kg (374.4 lb)     |
161.4 kg (356 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #4 (6 total)     | 1-of #8 Ld     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.541 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.27 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Wind 12 layers with 18 turns per layer = 216 turns. Insert 12.70 mm (0.5 inch) vent spacer after layers 6 and 6 in the coil heads |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1978 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 381.0 mm (15 inch)     |
393.70 mm (15.5 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-13     | 1-2     | |||||
Turns/Coil     | 5     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 1 of 2.0574 mm (0.081 inch) x 7.3406 mm (0.289 inch)     |
1 of #6 square     | |||||
Mean Length Turn     | 1656.08 mm (65.2 inch)     |
1330.96 mm (52.4 inch)     |
|||||
Copper Weight     | 169.82 kg (374.4 lb)     |
161.4 kg (356 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #4 (6 total)     | 1-of #8 Ld     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.541 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.27 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Wind 12 layers with 18 turns per layer = 216 turns. Insert 12.70 mm (0.5 inch) vent spacer after layers 6 and 6 in the coil heads |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1984 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 508.0 mm (20 inch)     |
520.70 mm (20.5 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-13     | 1-2     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 1 of 3.8100 mm (0.150 inch) x 7.7470 mm (0.305 inch)     |
#6 Square Heavy Film     | |||||
Mean Length Turn     | 1988.8200 mm (78.3 inch)     |
1584.9600 mm (62.4 inch)     |
|||||
Copper Weight     | 154.2 kg (340 lb)     |
215.4 kg (475 lb)     |
|||||
Inside Connection (1)     | Series Wye     |     | |||||
Line Leads (No. & Size)     | 6-1 #2 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.249 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.488 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Wind 12 layers with 18 turns per layer = 216 turns. Insert 12.70 mm (0.5 inch) vent spacer after layers 6 and 6 in the coil heads |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1986 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 508.0 mm (20 inch)     |
520.70 mm (20.5 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-13     | 1-2     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 1 of 3.8100 mm (0.150 inch) x 7.7470 mm (0.305 inch)     |
#6 Square Heavy Film     | |||||
Mean Length Turn     | 1988.8200 mm (78.3 inch)     |
1584.9600 mm (62.4 inch)     |
|||||
Copper Weight     | 154.2 kg (340 lb)     |
215.4 kg (475 lb)     |
|||||
Inside Connection (1)     | Series Wye     |     | |||||
Line Leads (No. & Size)     | 6-1 #2 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.249 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.488 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Wind 12 layers with 18 turns per layer = 216 turns. Insert 12.70 mm (0.5 inch) vent spacer after layers 6 and 6 in the coil heads |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1990 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 596.90 mm (23.5 inch)     |
609.6 mm (24 inch)     |
|||||
Slots     | 60     | 4     | |||||
Coil Throw     | 1-11     |     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 2 of 4.0640 mm (0.160 inch) x 4.9530 mm (0.195 inch) 2 Wide x 1 High     |
#6 Square     | |||||
Mean Length Turn     | 2169.16 mm (85.4 inch)     |
1755.902 mm (69.13 inch)     |
|||||
Copper Weight     | 185.5 kg (409 lb)     |
225.4 kg (497 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #1 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.1706 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.686 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Wind 12 layers with 18 turns per layer = 216 turns. Insert 12.70 mm (0.5 inch) vent spacer after layers 6 and 6 in the coil heads |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1992 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 469.90 mm (18.5 inch)     |
482.6 mm (19 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-13     | 1 - 2     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 4 - 2.1590 mm (0.085 inch) x 4.4450 mm (0.175 inch) 2 WIDE X 2 HIGH     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch)     |
|||||
Mean Length Turn     | 1879.6 mm (74 inch)     |
1536.70 mm (60.5 inch)     |
|||||
Copper Weight     | 182.7 kg (403 lb)     |
349.2 kg (770 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #1 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.206 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 0.876 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-1996 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 520.70 mm (20.5 inch)     |
533.4 mm (21 inch)     |
|||||
Slots     | 60     | 4     | |||||
Coil Throw     | 1-11     | 1 - 2     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 2 of 4.2672 mm (0.168 inch) x 5.7912 mm (0.228 inch) 1 High x 2 Wide     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch)     |
|||||
Mean Length Turn     | 2073.910 mm (81.65 inch)     |
1638.30 mm (64.5 inch)     |
|||||
Copper Weight     | 229.0 kg (505 lb)     |
371.9 kg (820 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #1/0 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.138 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 0.9324 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2000 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 584.2 mm (23 inch)     |
596.90 mm (23.5 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-13     | 1 - 2     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 2 - 2.5908 mm (0.102 inch) x 4.1148 mm (0.162 inch)     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch)     |
|||||
Mean Length Turn     | 2225.04 mm (87.6 inch)     |
1765.30 mm (69.5 inch)     |
|||||
Copper Weight     | 199.5 kg (440 lb)     |
400.0 kg (882 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #2/0 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.143 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.003 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2002 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 660.4 mm (26 inch)     |
673.10 mm (26.5 inch)     |
|||||
Slots     | 96     | 4     | |||||
Coil Throw     | 1-17     | 1 - 2     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 2 of 4.6228 mm (0.182 inch) x 5.8166 mm (0.229 inch) 2 High x 1 Wide     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch) Heavy Film     |
|||||
Mean Length Turn     | 2565.4 mm (101 inch)     |
1917.70 mm (75.5 inch)     |
|||||
Copper Weight     | 226.7 kg (500 lb)     |
435.4 kg (960 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #2/0 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.113 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.12 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2004 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 711.2 mm (28 inch)     |
723.90 mm (28.5 inch)     |
|||||
Slots     | 60     | 4     | |||||
Coil Throw     | 1-11     | 1 - 2     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 4 of 3.2258 mm (0.127 inch) x 5.5626 mm (0.219 inch)     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch) Heavy Film     |
|||||
Mean Length Turn     | 2473.96 mm (97.4 inch)     |
2019.30 mm (79.5 inch)     |
|||||
Copper Weight     | 292.5 kg (645 lb)     |
458.1 kg (1010 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #4/0     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.083 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.17 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2006 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA (4)     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 742.950 mm (29.25 inch)     |
755.650 mm (29.75 inch)     |
|||||
Slots     | 60     | 4     | |||||
Coil Throw     | 1-11     | 1 - 2     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 4 - 3.9370 mm (0.155 inch) x 5.5372 mm (0.218 inch) 2 Wide x 2 High     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch) Heavy Film     |
|||||
Mean Length Turn     | 2743.2 mm (108 inch)     |
    | |||||
Copper Weight     | 385.5 kg (850 lb)     |
471.7 kg (1040 lb)     |
|||||
Inside Connection (1)     | Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 # 4/0 (6 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.0694 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.179 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 4 ) | 50Hz, 1500rpm ratings - PP:2500/2000 SB:2781/2225 |
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2024 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 368.30 mm (14.5 inch)     |
381.0 mm (15 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-14     | 1-2     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 13 of # 13     | #6 Square     | |||||
Mean Length Turn     | 1765.30 mm (69.5 inch)     |
1298.702 mm (51.13 inch)     |
|||||
Copper Weight     | 117.9 kg (260 lb)     |
166.64 kg (367.4 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6 - 4 of #1     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00905 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.27 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 04 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2026 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 368.30 mm (14.5 inch)     |
381.0 mm (15 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-14     | 1-2     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 13 of # 13     | #6 Square     | |||||
Mean Length Turn     | 1765.30 mm (69.5 inch)     |
1298.702 mm (51.13 inch)     |
|||||
Copper Weight     | 117.9 kg (260 lb)     |
166.64 kg (367.4 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6 - 4 of #1     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00905 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.27 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 04 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2028 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 381.0 mm (15 inch)     |
393.70000 mm (15.5 inch)     |
|||||
Slots     | 96     | 4     | |||||
Coil Throw     | 1-20     | 1-2     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 13 of # 13     | #6 Square     | |||||
Mean Length Turn     | 2004.06 mm (78.9 inch)     |
1330.96 mm (52.4 inch)     |
|||||
Copper Weight     | 120.2 kg (265 lb)     |
161.4 kg (356 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6 - 4 of # 1/0     | 1-of #8 Ld     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00846 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.27 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 04 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2030 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 381.0 mm (15 inch)     |
393.70000 mm (15.5 inch)     |
|||||
Slots     | 96     | 4     | |||||
Coil Throw     | 1-20     | 1-2     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 13 of # 13     | #6 Square     | |||||
Mean Length Turn     | 2004.06 mm (78.9 inch)     |
1330.96 mm (52.4 inch)     |
|||||
Copper Weight     | 120.2 kg (265 lb)     |
161.4 kg (356 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6 - 4 of # 1/0     | 1-of #8 Ld     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00846 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.27 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 04 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2036 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 508.0 mm (20 inch)     |
520.70 mm (20.5 inch)     |
|||||
Slots     | 84     | 4     | |||||
Coil Throw     | 1-15     | 1-2     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 36 of # 13     | #6 Square Heavy Film     | |||||
Mean Length Turn     | 2080.26 mm (81.9 inch)     |
1584.96 mm (62.4 inch)     |
|||||
Copper Weight     | 149.6 kg (330 lb)     |
215.4 kg (475 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     |     | |||||
Line Leads (No. & Size)     | 6 - 4 of # 2/0 SIL     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00592 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.488 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2038 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 508.0 mm (20 inch)     |
520.70 mm (20.5 inch)     |
|||||
Slots     | 84     | 4     | |||||
Coil Throw     | 1-15     | 1-2     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 36 of # 13     | #6 Square Heavy Film     | |||||
Mean Length Turn     | 2080.26 mm (81.9 inch)     |
1584.96 mm (62.4 inch)     |
|||||
Copper Weight     | 149.6 kg (330 lb)     |
215.4 kg (475 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     |     | |||||
Line Leads (No. & Size)     | 6 - 4 of # 2/0 SIL     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00592 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.488 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2042 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 596.90 mm (23.5 inch)     |
609.6 mm (24 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-14     |     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 216 (3)     | |||||
No. & Wire Size     | 25 of # 13     | #6 Square     | |||||
Mean Length Turn     | 2161.54 mm (85.1 inch)     |
1755.902 mm (69.13 inch)     |
|||||
Copper Weight     | 153.3 kg (338 lb)     |
225.4 kg (497 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6 - 4 of # 4/0     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00415 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.686 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | 12 layers, 18 turns per layer. Layer wound with 12.70 mm (0.5 inch) vent opening to divide layers 6-6 in coil head |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2080 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 469.90 mm (18.5 inch)     |
482.6 mm (19 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-15     | 1 - 2     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 10 - 4.1148 mm (0.162 inch) x 5.1816 mm (0.204 inch) 2 wide X 5 high     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch)     |
|||||
Mean Length Turn     | 2197.10 mm (86.5 inch)     |
1536.70 mm (60.5 inch)     |
|||||
Copper Weight     | 297.1 kg (655 lb)     |
349.2 kg (770 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6 - 4 of # 3/0     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00288 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 0.876 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2084 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 520.70 mm (20.5 inch)     |
533.4 mm (21 inch)     |
|||||
Slots     | 84     | 4     | |||||
Coil Throw     | 1-15     | 1 - 2     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 5 of 3.6830 mm (0.145 inch) X 8.2550 mm (0.325 inch) 1 wide X 5 high     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch)     |
|||||
Mean Length Turn     | 2169.16 mm (85.4 inch)     |
1638.30 mm (64.5 inch)     |
|||||
Copper Weight     | 251.7 kg (555 lb)     |
371.9 kg (820 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-8 of #3/0 (48 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00114 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 0.9324 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 29 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
144-2088 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 584.2 mm (23 inch)     |
596.90 mm (23.5 inch)     |
|||||
Slots     | 60     | 4     | |||||
Coil Throw     | 1-12     | 1 - 2     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 216.5 (3)     | |||||
No. & Wire Size     | 6 - 3.4798 mm (0.137 inch) x 6.2230 mm (0.245 inch)     |
3.6068 mm (0.142 inch) x 7.7470 mm (0.305 inch)     |
|||||
Mean Length Turn     | 2308.86 mm (90.9 inch)     |
1765.30 mm (69.5 inch)     |
|||||
Copper Weight     | 328.8 kg (725 lb)     |
400.0 kg (882 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6 - 8 of # 1/0 (48 total)     | #8     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00205 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.003 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 60 Hz     | 120 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 175     | 18     | 12     | ||||
No. & Size Wire     | 2 of #16     | 4 #18     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.8 ohms     | 0.159 ohms     | 0.239 ohms     | ||||
Copper Weight     | 12.92 kg (28.5 lb)     |
5.53 kg (12.2 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 - #14     | 3 of #10 (3-Total)     | 3-1 OF #14 (3-Total)     |
Show/hide table
( 3 ) | Layer wound with 12.70 mm (0.5 inch) vent openings to be divided at layers 9-8 in the coil head. (wind 9 layers - put in spacer - wind last 8 layers). |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 29 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
Caterpillar Information System:
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 136-6610 Generator through 136-6641 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 144-1666 Generator through 144-1766 Generator
3512C Petroleum Engines with Dynamic Gas Blending Engine Shutdown Occurrence
312D2 and 313D2 Excavators System Pressure Release
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 141-5534 Generator through 142-9900 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 136-6580 Generator through 136-6609 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 126-8022 Generator through 128-7424 Generator
C1.7, C1.8 and C2.4 Tier 4 Interim and EU Stage 3A Engines for Caterpillar Built Machines Engine Oil Pressure Switch
CX31 and CX31 HT On-Highway Transmissions (Cat Truck) Transmission Hydraulic Control
2013/09/20 A Rework Procedure for the Power Access Stairway (PAS) On Certain Off-Highway Trucks is Now Available {7253}
2013/09/27 New Software Is Now Available for All Cat® Products With The Product Link 522 System {7606}
Rework Procedure for the PAS (Powered Access Stairway) on Certain Off-Highway Trucks{0679, 7253, 7254, 7255} Rework Procedure for the PAS (Powered Access Stairway) on Certain Off-Highway Trucks{0679, 7253, 7254, 7255}
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 149-2447 Generator through 150-9152 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 158-6410 Generator through 163-8546 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 164-0975 Generator through 164-4946 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 173-7078 Generator through 194-6563 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 203-5749 Generator through 324-5120 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 6I-0053 Generator through 6I-4860 Generator
2013/11/11 An Improved ARD Combustion Head is Now Used on the Tier 4 Engines of Certain Machines {108B, 108E, 108M}
2013/11/21 An Improved ARD Combustion Head is Now Used on Certain Tier 4 Engines {108B, 108E, 108M}
Installation of G610 Hardware for Cat® Terrain for Motor Graders, Wheel Dozers, and Wheel Loaders {7605} Installation of G610 Hardware for Cat® Terrain for Motor Graders, Wheel Dozers, and Wheel Loaders {7605}
3512C Oil Well Service Engines Air Shutoff - Test
793F and 797F Off-Highway Trucks Braking System Automatic Retarder Control (ARC)
3500E EPA Tier 4 Final and IMO-II/III Switchable Marine Engines Sensor Calibration Required - Test