320E and 323E Excavators Machine System Specifications Caterpillar


Relief Valve (Negative Flow Control)

Usage:

320E AWS


Illustration 1g03341741

Table 1
Specification for 335-0169 Solenoid and Relief Valve Gp 
Item  Qty  Part  Specification Description 
109-2667 Relief Valve Gp  Lubricate the bores lightly with the lubricant that is being sealed.
Torque to 145 ± 15 N·m (107 ± 11 lb ft)
148-8411 Plug  Torque to 60 to 66 N·m (44 to 49 lb ft)
14  225-4818 Plug As  Torque to 10 ± 1 N·m (89 ± 9 lb in)
111-9916 Solenoid Valve Gp  Lubricate the bores lightly with the lubricant that is being sealed. 
7I-2272 Bolt  Torque to 7 ± 1 N·m (62 ± 9 lb in)

Caterpillar Information System:

C13, C15, and C18 Tier 4 Final Engines Turbocharger
C4.4 Industrial Engine Electronic Control Module - Install
C4.4 Industrial Engine Electronic Control Module - Remove
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Configuration - Adjust
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Power Supply - Check
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Input Power - Test
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz System Startup
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Cabinet - Check
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Configuration - Check
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz System Shutdown
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Metering - Check
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Unit Initial Check
C3.4B Engines For Caterpillar Built Machines Fuel Filter Base - Primary Fuel Filter Base
TA19 Agriculture Transmission Electronic Control System Transmission, SPN 1542 - FMI 3
TA19 Agriculture Transmission Electronic Control System Transmission, SPN 1542 - FMI 4
TA19 Agriculture Transmission Electronic Control System MID 081 - CID 0177 - FMI 03
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz DC Bus Voltage - Test
C15 Generator Sets Safety Messages
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz On-Battery - Check
C32 Auxiliary Engine Cold Weather Starting
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Manual Transfer - Check
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz Unit Final Check
UPSB505 Uninterruptible Power Supply UPS Battery - 50Hz IGBT for CSIEN-CSION-CSPEN Circuit Board - Replace
2011/10/13 Replacement and Adjustment Procedures for the Fan Drive of Certain Commercial Engines {1359}
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.