CID 0110 FMI 03
Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the following conditions:
- The signal voltage from the engine coolant temperature sensor is greater than 4.95 Volts DC for more than eight seconds.
- The ECM has been powered for at least two seconds.
System Response:
If equipped, the diagnostic lamp will flash. An active diagnostic code will be generated after 8 seconds. The diagnostic code will be logged if the engine has been operating for more than 7 minutes.
The ECM will default to 90 °C (194 °F) for engine coolant temperature. "Voltage Above Normal" will be displayed next to the status for "Engine Coolant Temperature" on the electronic service tool.
- Poor stability
- Poor cold running
- White smoke
The diagnostic code will detect an excessively high voltage from the engine coolant temperature sensor.
Test Step 1. Perform the following diagnostic procedure: Engine Temperature Sensor Open or Short Circuit - Test
Results:
- OK - STOP
Caterpillar Information System:
C6.6 Generator Set CID 0100 FMI 10
C6.6 Generator Set CID 0100 FMI 04
C6.6 Generator Set CID 0100 FMI 03
C6.6 Generator Set CID 0004 FMI 06
C6.6 Generator Set CID 0004 FMI 05
C6.6 Generator Set CID 0004 FMI 02
Track, Track Roller, and Track Idler Cycle Times {4159, 4169, 4170, 4171, 4180} Track, Track Roller, and Track Idler Cycle Times {4159, 4169, 4170, 4171, 4180}
2010/01/14 New Communication Software for the PL1000T Is Now Used on Commercial Engines {7606, 7620}
3508, 3512 and 3516 Generator Set Engines Camshaft Bearings - Install
C6.6 Generator Set CID 0003 FMI 06
C6.6 Generator Set CID 0003 FMI 05
C6.6 Generator Set CID 0003 FMI 02
C6.6 Generator Set CID 0110 FMI 04
C6.6 Generator Set CID 0168 FMI 00
3508, 3512 and 3516 Generator Set Engines Crankshaft - Remove
C6.6 Generator Set CID 0168 FMI 01
C6.6 Generator Set CID 0168 FMI 02
C6.6 Generator Set CID 0172 FMI 03
C6.6 Generator Set CID 0172 FMI 04
C6.6 Generator Set CID 0190 FMI 08
C6.6 Generator Set CID 0247 FMI 09
C9.3 Engines for Caterpillar Built Machines Idle Speed Is High
C6.6 Generator Set CID 0253 FMI 02
C6.6 Generator Set CID 0262 FMI 03