PRODUCT SUPPORT PROGRAM FOR REPLACING THE ELECTRONIC MODULAR CONTROL PANEL (EMCP 4.1 OR EMCP 4.2) ON CERTAIN C15, C18, 3406C, 3512B, AND 3516B GENERATOR SETS Caterpillar
PRODUCT SUPPORT PROGRAM FOR REPLACING THE ELECTRONIC MODULAR CONTROL PANEL (EMCP 4.1 OR EMCP 4.2) ON CERTAIN C15, C18, 3406C, 3512B, AND 3516B GENERATOR SETS
Usage:
TEBE4445-00
Show/hide table
25Jul2016
K290
K660
M668
Show/hide table
Before/After
(Limited distribution)
PRODUCT SUPPORT PROGRAM FOR REPLACING THE ELECTRONIC MODULAR CONTROL PANEL (EMCP 4.1 OR EMCP 4.2) ON CERTAIN C15, C18, 3406C, 3512B, AND 3516B GENERATOR SETS
4490
PS45167
Show/hide table
NOTE:
Caterpillar’s obligations under this Service Letter are subject to, and shall not apply in contravention of, the laws, rules, regulations, directives, ordinances, orders, or statutes of the United States, or of any other applicable jurisdiction, without recourse or liability with respect to Caterpillar.
NOTE:
This Program must be administered either before or after failure.
In either case the decision whether to apply the Program is made by the dealer. When reporting the repair, use "PS45167" as the Part Number
and "7755" as the Group Number. If administered before failure, use "56" as the Warranty Claim Description Code and "T" as the SIMS Description code.
If administered after failure, use "96" as the Warranty Claim Description Code, and "Z" as the SIMS Description Code.
Show/hide table
NOTE:
The information supplied in this service letter may not be valid after the termination date of this program.
Do not perform the work outlined in this Service Letter after the termination date without first contacting your Caterpillar product analyst.
Show/hide table
Show/hide table
Show/hide table
Show/hide table
TERMINATION DATE
31Jul2018
PROBLEM
Show/hide table
The EMCP overlay buttons may fail to operate on certain C15, C18, 3406C, 3512B, and 3516B Generator Sets. The failure results in operators being unable to navigate through the controller overview and configuration menus or non operation of the Run, Stop and Auto buttons. This failure mode is not to be confused with a software reset issue while in Reduced Power Mode referenced in Engine News SEBD9946.
In order to allow equitable parts availability to all participating dealers, please limit your initial parts order to not exceed 18% of dealership population. This is an initial order recommendation only, and the ultimate responsibility for ordering the total number of parts needed to satisfy the program lies with the dealer.
In order to allow equitable parts availability to all participating dealers, please limit your initial parts order to not exceed 23% of dealership population. This is an initial order recommendation only, and the ultimate responsibility for ordering the total number of parts needed to satisfy the program lies with the dealer.
ACTION REQUIRED
Show/hide table
If a confirmed Navigation, Run, Start or Stop button failure occurs, replace the EMCP.
Show/hide table
SERVICE CLAIM ALLOWANCES
Show/hide table
Product smu/age whichever comes first
Caterpillar
Dealer Suggested
Customer Suggested
Parts %
Labor Hrs%
Parts %
Labor Hrs%
Parts %
Labor Hrs%
*******Group 1*******
0-8000 hrs, 0-24 mo
100.0%
100.0%
0.0%
0.0%
0.0%
0.0%
NOTE: This is a 1.5-hour job for Group 1
Show/hide table
Product smu/age whichever comes first
Caterpillar
Dealer Suggested
Customer Suggested
Parts %
Labor Hrs%
Parts %
Labor Hrs%
Parts %
Labor Hrs%
*******Group 2*******
0-8000 hrs, 0-24 mo
100.0%
100.0%
0.0%
0.0%
0.0%
0.0%
NOTE: This is a 1.5-hour job for Group 2
PARTS DISPOSITION