Usage:
Typical Illustration
7L6791 and 3N8861 Transformers for Fairbanks Morse Solid State Magneto
Resistance:
Primary coil measured between positive post (2) and negative post (3) of transformer ... .3 to .6 ohms
Secondary coil measured between negative post (3) of transformer and outlet (1) for the high current (tension) ... 11 000 to 13 000 ohms
2W3747 Transformer for Altronic Solid State Magneto
Resistance:
Primary coil measured between positive post (2) and negative post (3) of transformer ... .1 to .2 ohms
Secondary coil measured between negative post (3) of transformer and outlet (1) for the high current (tension) ... 5000 to 8000 ohms
4W5439 Transformer for Altronic Solid State Magneto (low emission)
Resistance:
Primary coil measured between positive post (2) and negative post (3) of transformer ... .3 to .5 ohms
Secondary coil measured between negative post (3) of transformer and outlet (1) for the high current (tension) ... 8200 to 18 000 ohms
9Y3986 Transformer for Altronic Solid State Magneto
Pin "A" is positive.
Pin "B" is negative.
Primary coil measured between positive post (A) and negative post (B) of transformer ... .2 to .4 ohms
Secondary coil measured between negative post (B) of transformer and outlet (1) for the high current (tension) ... 8000 to 9600 ohms