C6.6 Generator Set Caterpillar


CID 1690 FMI 08

Usage:

C6.6DE150E ECR
Conditions Which Generate This Code:

Although the signal from the analog throttle is within the normal range of 0.5 Volts to 4.5 Volts, the signal has an abnormal frequency, an abnormal pulse width or an abnormal time period.

System Response:

The Electronic Control Module (ECM) will log the diagnostic code.

The warning lamp will illuminate and the diagnostic lamp will flash.

The engine speed changes to the default selected speed of 1500 rpm or 1800 rpm.

Test Step 1. Perform the following diagnostic procedure: Speed Control (Analog) - Test

Results:

  • OK - STOP

Caterpillar Information System:

Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.