Usage:

988G 2TW

Type 1




Illustration 1g00286672



Illustration 2g00286673

When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise

No load conditions at 25°C (77°F)

Speed ... 7643 ± 1683 rpm
Current draw ... 67.5 ± 7.5 amp
Voltage ... 23 V

(1) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(2) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)

(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)

(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (71 ± 27 lb in)

9X-9511 Starting Motor Solenoid Assembly

Current consumption at 25°C (77°F)

Pull-in windings at 20V ... 56.5 ± 4.5 Amp
Hold-in windings at 20V ... 14.6 Amp

Type 2




Illustration 3g00286676



Illustration 4g00286677

When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... Clockwise

No load conditions at 25°C (77°F)

Speed ... 5500 rpm minimum
Current draw ... 140 Amp maximum
Voltage ... 24 V

(1) Tighten the nut on the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(2) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(3) Tighten the nut on the ground terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)

(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)

(5) Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(6) Tighten the nut on the motor frame terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

9X-0332 Solenoid Kit

Current consumption at 25°C (77°F)

Pull-in windings at 24V ... 51 Amp
Hold-in windings at 24V ... 7 Amp

Type 3




Illustration 5g00282453



Illustration 6g00282454

When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise

No load conditions at 25 °C (77 °F)

Minimum speed with no load ... 3300 rpm
Maximum current with no load ... 80 amp
Voltage ... 23.5 V

(1) Nut

Three wires are the maximum that may fit between the nuts.
Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(2) Nut

Tighten the nut to the following torque. ... 1.5 ± 0.5 N·m (13 ± 4 lb in)

(3) Nut

Tighten the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(4) Nut

The terminal that is on the switch terminal must be insulated with heat shrink tubing.
Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)

(5) Nut

Tighten the nut on the motor terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)

(6) Nut

Tighten the nut on the motor frame terminal to the following torque. ... 17.5 ± 2.5 N·m (13 ± 2 lb ft)

3E-0135 Solenoid

Current draw at 24 V and 25 °C (77 °F)

Pull-in windings ... 103 Amp
Hold-in windings ... 19 Amp maximum