Electronic Modular Control Panel II (EMCP II) For PEEC Engines Caterpillar


AL Fault Codes

Usage:

3412 2WJ
AL fault codes are shown as AL1 through AL3 on the upper display. The fault codes include specific engine fault conditions. For example, a specific fault would be low engine oil pressure. The fault codes also include functions for protective relaying. The underfrequency fault is an example of a protective relaying function.

AL fault codes rely upon certain setpoints. See Systems Operation, "Service Mode" for more information on setpoints. AL fault codes are not stored in the fault log of the GSC. Many of the AL fault codes are programmable as a fault alarm or as a fault shutdown. To show the severity of the fault, the AL fault codes are accompanied by the fault alarm indicator, or the fault shutdown indicator on the GSC. The AL fault codes and the related setpoints are described in the paragraphs that follow.

AL1 High Water Temperature Alarm - The GSC issues a high water temperature shutdown when the engine coolant temperature comes within 6°C (11°F) of setpoint P15. The fault alarm indicator will FLASH. The AL1 fault code is shown on the upper display after the "Alarm Fault Codes" key is pressed.

P15 is the setpoint for high water temperature shutdown. The GSC uses the temperature in order to declare that a high water temperature shutdown is present. When the setpoint is reached, the dedicated shutdown indicator for high water temperature FLASHES and the engine is shutdown.

AL2 Low Water Temperature Alarm - When the engine coolant temperature decreases to setpoint P16, the GSC issues a low water temperature alarm. The fault alarm indicator will FLASH and the AL2 fault code is shown on the upper display after the alarm codes key is pressed.

P16 is the setpoint for a low water temperature alarm. This setpoint tells the GSC when a low water temperature alarm "(AL2)" exists.

AL3 Low Oil Pressure Alarm - The GSC issues a low oil pressure alarm when the engine oil pressure drops to within 34 kPa (5 psi) of the P13 setpoint or the P14 setpoint. The fault alarm indicator will FLASH and the "AL3" fault code is shown on the upper display after the alarm codes key is pressed.

P13 is the setpoint for low oil pressure shutdown at rated speed. When the setpoint is reached, the dedicated shutdown indicator for low oil pressure flashes and the engine is shut down.

P14 is the setpoint for low oil pressure shutdown at idle speed. When the setpoint is reached, the dedicated shutdown indicator for low oil pressure FLASHES and the engine is shutdown.

Caterpillar Information System:

3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0273 - FMI 00 Turbo Outlet Pressure above normal
3126B Marine Engine Water Temperature Regulator
3126B and 3126E Truck Engines Crankcase Breather
3126B Marine Engine Engine Oil Pan
Electronic Modular Control Panel II (EMCP II) For PEEC Engines Hourmeter Programming OP7
561N, 572R Series II and 572R Pipelayers and D10R, D11R, D5M, D5N, D6M, D6N, D6R, D6R Series II, D7R, D7R Series II and D8R Series II Track-Type Tractors Power Train Electronic Control System Electronic Control Module (ECM) - Replace
3612 and 3616 Engines Accessory Drive
G3606 and G3608 Engines Gas Pressure Regulator - Install
3500B and 3500B High Displacement Generator Set Engines Engine Speed/Timing Sensor - Calibrate
3176C and 3196 Industrial Engines Engine Monitoring System (EMS)
3612 and 3616 Engines Accessory Drive
3406E and 3456 Generator Set Engines Engine Oil Filter Base - Install
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0275 - FMI 03 Right Turbo Inlet Pressure open/short to +batt
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0275 - FMI 04 Right Turbo Inlet Pressure short to ground
3612 and 3616 Engines Flywheel
Electronic Modular Control Panel II (EMCP II) For MUI Engines Diagnostic Codes
3612 and 3616 Engines Engine Support
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0275 - FMI 13 Right Turbo Inlet Pressure calibration required
3612 and 3616 Engines Engine Support
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0276 - FMI 03 Left Turbo Inlet Pressure open/short to +batt
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0276 - FMI 04 Left Turbo Inlet Pressure short to ground
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0289 - FMI 03 Unfiltered Fuel Pressure open/short to +batt
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0289 - FMI 13 Unfiltered Fuel Pressure calibration required
3500B and 3500B High Displacement Generator Set Engines MID 036 - CID 0336 - FMI 02 Incorrect ECS Switch inputs