C27 Engine for the AD55B Underground Articulated Truck Caterpillar


Configuration Parameters

Usage:

AD55B JNW
Use this procedure if the diagnostic code in Table 1 is active.

Table 1
Diagnostic Codes Table    
Code and Description     Conditions which Generate this Code     System Response    
268-2 Programmed Parameter Fault : Erratic, Intermittent, or Incorrect     The engine's Electronic Control Module (ECM) detects that one or more of the programmable parameters have not been programmed.     The ECM may use a default torque map or the ECM may limit the engine to low idle.
The code is active only.    

System configuration parameters are parameters that affect emissions, power of the engine, and other features that define the characteristics of the engine subsystems. The parameters are preprogrammed at the factory. You may need to reprogram the system configuration parameters if the Electronic Control Module (ECM) is replaced and/or if you reprogram the engine rating. You do not need to reprogram the system configuration parameters if you replace the flash file. Caterpillar Electronic Technician (ET) can be used to view the values for these parameters at any time. Certain system configuration parameters are stamped on the engine information plate.

Note: The unauthorized tampering with the parameters that are protected by factory passwords may cause your Caterpillar warranty to be voided.

The system configuration parameters are listed in Table 2.

Table 2
System Configuration Parameters    
Parameter     Parameter Setting    
ECM Identification Parameters    
Equipment ID (1)     17 alphanumeric characters    
Engine Serial Number (1)     0XX00000 or XXX00000    
ECM Part Number (2)     Read Only    
ECM Serial Number (2)     Read Only    
Software Group Part Number (2)     Software Dependent    
Software Group Release Date (2)     Software Dependent    
Software Group Description (2)     Software Dependent    
Engine Configuration Parameters    
Engine Fan Control     Enabled/
Disabled    
Maintenance Parameters    
Maintenance Indicator Mode     "OFF"
"Auto Fuel"
"Auto Hour"
"Man Fuel"
"Man Hour"    
Maintenance Level 1 Cycle Interval Hours     Man Hour
0 to 32676
Man Fuel
3785 L (1000 US gal)
to

2839066 L (75000 US gal)    
System Settings    
FLS (Full Load Setting) (1)     Programmed at the factory    
FTS (Full Torque Setting) (1)     Programmed at the factory    
Security Access Parameters    
Total Tattletale     Read Only    
( 1 ) The parameter must be reprogrammed if the ECM is replaced.
( 2 ) This parameter can only be viewed. No changes are allowed.

Parameter Descriptions

ECM Identification Parameters

Equipment ID

"Equipment ID" allows the customer to enter a description into the ECM in order to identify the installation. A maximum of 17 characters may be entered in the field. This parameter is only for reference by the customer. This parameter is not required.

Engine Serial Number

Program the "Engine Serial Number" to match the engine serial number that is stamped on the engine information plate.

Note: When you are requesting factory passwords, always use the engine serial number that is resident in the ECM.

ECM Part Number

This parameter identifies the part number of the ECM.

ECM Serial Number

The "ECM Serial Number" is stored in the memory of the ECM. The "ECM Serial Number" can be accessed by the use of Cat ET.

Software Group Part Number

This parameter identifies the part number of the flash file that is currently installed in the ECM.

Software Group Release Date

This parameter identifies the release date of the flash file that is currently installed in the ECM.

Software Group Description

This parameter identifies the description of the application for the flash file that is currently installed in the ECM.

Engine Configuration Parameters

Engine Fan Control

This parameter must be enabled, in order for the ECM to control the engine's fan.

Maintenance Parameters

Maintenance Indicator Mode

The ECM records data that is related to equipment maintenance. The ECM will activate the maintenance indicator lamp when scheduled maintenance is due. The maintenance indicator lamp can be reset by actuating the maintenance clear switch. The maintenance interval may be based on operating hours or on fuel consumption. The ECM provides information that pertains to maintenance intervals and the last maintenance that was performed.

Maintenance Level 1 Cycle Interval Hours

This parameter allows the customer to define the maintenance interval if "Maintenance Indicator Mode" is programmed to one of the manual options. Refer to the Operation and Maintenance Manual for more information.

System Settings

Full Load Setting (FLS)

FLS is a parameter that represents the adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information plate. Only change this value if the engine is rerated or if a new ECM has been installed. Factory passwords are required to change this parameter.

Full Torque Setting (FTS)

FTS is similar to FLS. Only change this value if the engine is rerated or if a new ECM has been installed. Factory passwords are required to change this parameter.

Parameter Worksheet

Table 3
System Configuration Parameters    
Parameter     Parameter Setting    
ECM Identification Parameters    
Equipment ID    
   
Engine Serial Number    
   
ECM Part Number    
   
ECM Serial Number    
   
Software Group Part Number    
   
Software Group Release Date    
   
Software Group Description    
   
Engine Configuration Parameters    
Engine Fan Control        
Maintenance Parameters    
Maintenance Indicator Mode        
Maintenance Level 1 Cycle Interval Hours        
System Settings    
FLS (Full Load Setting)    
   
FTS (Full Torque Setting)    
   
Security Access Parameters    
Total Tattletale    
   

Caterpillar Information System:

120K Motor Grader Steering Frame Lock
120K and 120K Series 2 Motor Graders Air System and Brakes Service Brake Control
C27 Engine for the AD55B Underground Articulated Truck System Overview
120K Motor Grader Backup Alarm
C27 Engine for the AD55B Underground Articulated Truck Component Location
C9 Engine and D7E Track-Type Tractors ECM Does Not Communicate with Other Modules
120K and 120K Series 2 Motor Graders Air System and Brakes Air Control Valve (Service Brake)
325D, 330D, 345C, M325C and M330D Excavators and M325D L MH and M325D MH Material Handlers Magnet Controller Using Caterpillar Electronic Technician to Determine Diagnostic Codes
793D Off-Highway Truck Restricted Visibility
AccuGrade® GPS (CD700) Settings - Save
325D, 330D, 345C, M325C and M330D Excavators and M325D L MH and M325D MH Material Handlers Magnet Controller Magnet Control, SPN 5005 - FMI 6
325D, 330D, 345C, M325C and M330D Excavators and M325D L MH and M325D MH Material Handlers Magnet Controller Magnet Control, SPN 5005 - FMI 5
120K and 120K Series 2 Motor Grader Hydraulic and Steering System Centershift Lock
120K Motor Grader Daily Inspection
2008/11/03 A Improved Procedure to Adjust the Stop Light Limit Switch {1432, 1435, 4269}
120K Motor Grader Moldboard Wear Strip - Inspect/Adjust/Replace
AccuGrade® GPS (CD700) Horizontal Guidance
CB54, CB54 XW and CB64 Vibratory Compactor Machine Systems Smooth Drum Scraper
120K Motor Grader Hydraulic System Oil Level - Check
C27 Engine for the AD55B Underground Articulated Truck Cooling Fan Speed - Test
12K, 140K and 160K Motor Graders Circle Drive Oil - Change
24M Motor Grader Assembly Instruction (Split Shipping Configuration){7000, 7960} 24M Motor Grader Assembly Instruction (Split Shipping Configuration){7000, 7960}
CS54 and CP54 Vibratory Soil Compactors Hydraulic System Oil Filter - Replace
785D OEM Off-Highway Truck Power Train Final Drive - Disassemble
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.