Illustration 1 | g01099999 |
Location of the remote pressure taps |
Illustration 2 | g01165044 |
Remote pressure taps |
The following pressures should be checked with the engine at high idle. The transmission oil should be at the normal operating temperature of 80 °C (176 °F).
(1) Transmission pressure for clutch 1 ... 2758 ± 140 kPa (400 ± 20 psi)
(2) Transmission pressure for clutch 2 ... 2758 ± 140 kPa (400 ± 20 psi)
(3) Transmission pressure for clutch 3 ... 2758 ± 140 kPa (400 ± 20 psi)
(4) Transmission pressure for clutch 4 ... 2758 ± 140 kPa (400 ± 20 psi)
(5) Transmission pressure for clutch 5 ... 2310 ± 140 kPa (335 ± 20 psi)
(6) Transmission pressure for clutch 6 ... 2758 ± 140 kPa (400 ± 20 psi)
(7) Torque converter inlet pressure ... 925 ± 50 kPa (135 ± 7.5 psi)
(8) Torque converter outlet pressure ... 415 ± 140 kPa (60 ± 20 psi)
(9) Minimum pressure for the transmission lubrication oil ... 105 kPa (15 psi)
(10) Transmission Pump Pressure ... 2758 ± 70 kPa (400 ± 10 psi)