279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System Caterpillar


MID 039 - CID 0358 - FMI 03

Usage:

256C DWS
Conditions Which Generate This Code:


Illustration 1g01269165

Schematic for theImplement Shutoff Solenoid Valve

This diagnostic code is associated with theImplement Shutoff Solenoid Valve. The FMI 03 means that the ECM has detected that the voltage of the solenoid circuit is above normal or that the ECM has detected voltage in the circuit when no voltage should be present.

Conditions that could cause this diagnostic code to be activated are:

  • The energize circuit of the solenoid is shorted to another voltage source.

  • The ECM has failed. This situation is unlikely.

Note: Before performing this procedure, inspect the harness connectors that are involved in the circuit. Poor connections can often be the cause of a problem in an electrical circuit. Verify that all connections in the circuit are clean, secure, and in good condition. If a problem with a connection is found, correct the problem and verify that this diagnostic code is active before performing this procedure.

Note: The following test procedure may create other diagnostic codes. Ignore these created diagnostic codes and clear these diagnostic codes when the original diagnostic code has been corrected.

Note: The resistance of the solenoid coil should be 7.5 ± 0.4 ohms at 20 °C (68.0 °F).

Test Step 1. CHECK THE ENERGIZE CIRCUIT OF THE SOLENOID FOR A SHORT

  1. Disconnect the negative battery cable and turn the key start switch to the OFF position.

  1. Disconnect the machine harness connector from the solenoid. Disconnect the machine harness connectors J1 and J2 from the ECM.

  1. At the machine harness ECM connectors, measure the resistance from contact J2-6 (wire M927-GN) to all of the other contacts that are used in the J1 and J2 connectors for the ECM.

Expected Result:

Each resistance measurement is greater than 5000 ohms.

Results:

  • YES - Each resistance measurement is greater than 5000 ohms. The resistance measurement does not indicate a short in the machine harness. Proceed to Test Step 2.

  • NO - Each resistance measurement is not greater than 5000 ohms. There is a short in the machine harness.

    Repair: The short is between wire G953-BU and the circuit that has a low resistance measurement.For information on testing for short circuits and finding short circuits, refer to Testing and Adjusting, "Wiring Harness (Short Circuit) - Test". Repair the machine harness or replace machine harness.

    STOP

Test Step 2. CHECK THE OPERATION OF THE ECM

The key start switch remains in the OFF position. The machine harness connectors for the solenoid and the ECM remain disconnected.

  1. At the machine harness connector J2 for the ECM, use a 151-6320 Removal Tool to remove the solenoid energize wire G953-BU and socket at contact J2-7 from the harness connector.

  1. Reconnect the machine harness J1 and J2 connectors to the ECM.

  1. Reconnect the negative battery cable and Turn the key start switch to the ON position.

  1. Observe the status of the active CID 0358 FMI 03 diagnostic code.

Expected Result:

The CID 0358 FMI 03 diagnostic code is no longer active. A CID 0358 FMI 05 diagnostic code is now active.

Results:

  • YES - The CID 0358 FMI 03 diagnostic code is no longer active. A CID 0358 FMI 05 diagnostic code has been activated after the solenoid energize circuit was disconnected. The ECM has responded correctly to the open circuit condition in the solenoid circuit.

    Reinstall the disconnected solenoid energize wire back into the correct space in the ECM connector before proceeding to the next test step.

    Proceed to Test Step 3.

  • NO - The CID 0358 FMI 03 diagnostic code remains active. The status of the active diagnostic code did not change when the solenoid energize wire was disconnected from the ECM.

    Repair: The ECM has not responded correctly to the open condition in the solenoid circuit. The operation of the ECM is not correct.Prior to replacing an ECM, always contact your the Technical Communicator for your dealer for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

Test Step 3. CHECK THE STATUS OF THE DIAGNOSTIC CODE

  1. Inspect the harness connectors and clean the contacts of the harness connectors. Check the wires for damage to the insulation that is caused by excessive heat, corrosion, or chafing.

  1. Perform a 45 N (10 lb) pull test on each of the wires that are associated with the circuit.

  1. Reconnect all harness connectors. Make sure that the connectors are fully seated and the clips for each connector are fastened.

  1. Turn the key start switch to the ON position.

  1. Operate the machine.

  1. Determine if the CID 0358 FMI 03 diagnostic code is active.

Expected Result:

The CID CID 0358 FMI 03 diagnostic code is active.

Results:

  • YES - The CID 0358 FMI 03 diagnostic code remains active.

    Repair: Check the circuit again. Use the Caterpillar Electronic Technician (ET) service tool, if available, in order to perform a "Wiggle Test" on the machine wiring harness. The wiggle test can detect momentary or intermittent shorts or opens in the machine wiring harness.If the problem remains, the ECM may have failed. This situation is unlikely because the ECM detected the open circuit condition in the solenoid circuit and activated the FMI 05 diagnostic code when the solenoid energize wire was disconnected.Verify that all possible causes of the diagnostic code have been investigated. Exit this procedure and perform this procedure again.Prior to replacing an ECM, always contact the Technical Communicator for your dealer for possible consultation with Caterpillar. This consultation may greatly reduce repair time. If the cause of the diagnostic code is not found and the ECM must be replaced, refer to Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

    STOP

  • NO - The CID 0358 FMI 03 code is not active. The problem does not exist at this time.

    Repair: The initial diagnostic code was probably caused by a poor electrical connection or a short at one of the harness connectors that was disconnected and reconnected. Resume normal machine operation.

    STOP

Caterpillar Information System:

279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0357 - FMI 13
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0357 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0357 - FMI 05
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2153 - FMI 04
938H and IT38H Wheel Loader and Integrated Tool Carrier Power Train Speed Sensor (Torque Converter Output) (Transmission Output)
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 2153 - FMI 03
120M and 12M Motor Graders Hydraulic System Oil - Change
120M, 12M, 140M, 14M, 160M and 16M Motor Graders Implement Electronic Control System MID 082 - CID 0296 - FMI 14
777E and 777F Off-Highway Truck Power Train Relief Valve (Transmission Lubrication)
M325D L MH and M325D MH Material Handlers Hydraulic System Flow (Medium Pressure/Cab Riser Function) - Adjust
Potential Vibratory Pump Failures on CP-533E and CS-533E Vibratory Soil Compactors{5050, 5095} Potential Vibratory Pump Failures on CP-533E and CS-533E Vibratory Soil Compactors{5050, 5095}
2006/05/22 A New Storage Position for the Mud Guards Is Available when the Machine Is Transported {4220}
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0358 - FMI 05
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0358 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0490 - FMI 03
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0490 - FMI 04
938H and IT38H Wheel Loader and Integrated Tool Carrier Power Train Temperature Sensor (Transmission Oil)
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0600 - FMI 03
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0600 - FMI 04
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0681 - FMI 03
RM-500 Road Reclaimer/Soil Stabilizer Power Train Piston Motor (Propel)
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0681 - FMI 05
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 0681 - FMI 06
279C, 279C2, 289C, 289C2 and 299C Compact Track Loaders, 287C, 277C, 277C2, 287C2 and 297C Multi Terrain Loaders and 246C, 256C, 262C, 262C2 and 272C Skid Steer Loaders Machine Electronic Control System MID 039 - CID 1007 - FMI 02
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.