Usage:
(1) Tighten the bolts in steps to a torque of ... 47 ± 9 N·m (35 ± 7 lb ft)
(2) Tighten the bolts in steps to a torque of ... 12 ± 3 N·m (9 ± 2 lb ft)
Pressure Regulating Valve For Air Starting Motor
(1) Adjusting bolt.
(2) Inlet pressure ... 1725 kPa (250 psi)
Maximum permissible pressure ... 3100 kPa (450 psi)
(3) Outlet pressure ... 620 to 760 kPa (90 to 110 psi)
Electric
6V5226 And 6V5538
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 3300 rpm minimum
Current draw ... 80A maximum
Voltage ... 23.5V
(1) Three cables or wire terminal maximum between nuts.
Two cable terminals maximum with 0 AWG or larger.
Torque for battery terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Torque for nut ... 1.5 ± 0.5 N·m (13 ± 4 lb in)
(3) Torque for ground terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(4) Torque for switch terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Torque for motor terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(6) Torque for motor frame terminal nut ... 17.5 ± 2.5 N·m (13 ± 2 lb ft)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 24V ... 103A
Hold in windings at 24V ... 19A
6V5207, 6V5537, 8C3647
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 7643 ± 1683 rpm
Current draw ... 67.5 ± 7.5A
Voltage ... 23V
Clearing between pinion and housing (pinion clearance) ... 9.1 mm (.34 in)
(1) Torque for ground terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Torque for ground terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(3) Three cables or wire terminal maximum between nuts.
Two cable terminals maximum with 0 AWG or larger.
Torque for battery terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(4) Torque for switch terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Torque for motor terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(6) Torque for motor frame terminal nut ... 8 ± 3 N·m (71 ± 27 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 20V ... 56.5 ± 4.5A
Hold in windings at 20V ... 14.6A
8C3596, 3E7864
Rotation as seen from drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 6900 ± 1800 rpm
Current draw ... 127.5 ± 27.5A
Voltage ... 11V
Clearing between pinion and housing (pinion clearance) ... 9.1 mm (.34 in)
(1) Torque for ground terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Torque for ground terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(3) Three cables or wire terminal maximum between nuts.
Two cable terminals maximum with 0 AWG or larger.
Torque for battery terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(4) Torque for switch terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Torque for motor terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(6) Torque for motor frame terminal nut ... 8 ± 3 N·m (71 ± 27 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 10V ... 92.5 ± 7.5A
Hold in windings at 10V ... 23A
6V5023, 7T0798, And 106-8552
Rotation as seen from the drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 5500 rpm minimum
Current draw ... 140A maximum
Voltage ... 24V
(1) Torque for large terminal nuts ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Torque for small terminal nuts ... 2.5 ± 0.25 N·m (22 ± 2 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 24V ... 51A
Hold in windings at 24V ... 7A
8C5580
Rotation as seen from the drive end ... Clockwise
No load conditions at 25°C (77°F):
Speed ... 3500 rpm minimum
Current draw ... 90A maximum
Voltage ... 23V
(1) Torque for ground terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(2) Torque for battery terminal nut ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(3) Torque for switch terminal screw ... 1.7 ± 0.25 N·m (15 ± 2 lb in)
Solenoid
Current consumption (draw) at 25°C (77°F):
Pull in windings at 24V ... 50A
Hold in windings at 24V ... 20A