C9 Marine Auxiliary and Marine Generator Set Engines Caterpillar


System Configuration Parameters

Usage:

C9 C9A
System configuration parameters are parameters that affect emissions, power of the engine, and engine applications. Default values for the parameters are programmed at the factory. Some parameters may be changed by the customer in order to suit the needs of the specific application. You must reprogram the system configuration parameters if the Electronic Control Module (ECM) is replaced. You do not need to reprogram the system configuration parameters if you program flash files. Certain configuration parameters are stamped on the engine information plate.

Note: If the parameters that are protected with the factory passwords are changed, the Caterpillar warranty may be voided.

Parameter Descriptions

"Rating Configuration"

The performance maps in the software

"Rated Real Genset Power"

The output power of the engine in kilowatts

"Rated Apparent Power"

The kVA rating of the engine

"Rated Frequency"

The line frequency of the generator

"Rating Number"

The Rating number corresponds to the selected set of performance maps for the application. This selected set of performance maps comes out of several unique sets of maps that may be resident in the flash file. The dealer and/or the OEM will need to select the appropriate rating tier, if more than one rating tier is present. The rating tier is A through E.

"Rated Engine Speed"

The optimum speed of the engine

"Engine Serial Number"

The engine serial number must be programmed to match the engine serial number that is stamped on the engine information plate. The engine serial number is not preprogrammed on a replacement ECM.

"Equipment ID"

This parameter allows the customer to enter a description into the ECM in order to identify the installation. A maximum of 17 characters can be entered in the field.

"Part Number of the Flash File"

The part number of the flash file is programmed into the software.

"The Release Date of the Flash File"

The release date of the flash file is programmed into the software.

"ECM Serial Number"

The ECM serial number is stored in the memory of the ECM.

"Total Tattletale"

The total tattletale counts the number of changes to system parameters.

"Low Idle Speed"

The parameter defines the low idle rpm.

"Engine Acceleration Rate"

The maximum ramp rate in order to reach desired engine speed.

"Engine Speed Droop"

This parameter allows the engine to operate in a load sharing system.

"Droop Mode Selection"

This parameter allows the customer to select droop or isochronous mode.

"Governor Gain Factor"

This parameter is used in determining the engine's rate of response to an engine load.

"Governor Minimum Stability Factor"

This parameter eliminates steady state speed error. The parameter is used by the ECM when the steady state speed error is less than 20 rpm.

"Governor Maximum Stability Factor"

This parameter eliminates steady state speed error. The parameter is used by the ECM when the steady state speed error is greater than 20 rpm.

"(FLS)" Full Load Setting

"FLS" is a number that represents the adjustment to the fuel system that was made at the factory in order to fine tune the fuel system. The correct value for this parameter is stamped on the engine information plate. Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required.

"(FTS)" Full Torque Setting

"FTS" is similar to "FLS". Only change this value if the engine is rerated or if a new ECM is installed. Factory passwords are required.

Parameter Table

Table 1
System Configuration Parameters    
Parameter     Available Range or Options     Default     Required Password    
Selected Engine Ratings    
"Rating Configuration"     Low Emissions or Low "Brake Specific Fuel Consumption (BSFC)"     Rated power     Read Only (1)    
"Rated Real Genset Power"     Kilowatts (if applicable)     Rated power     Read Only (1)    
"Rated Apparent Genset Power"     Kilowatts (if applicable)     Rated power     Read Only (1)    
"Rated Standby Genset Power"     Software Dependent     Read Only (1)    
"Rated Frequency"     Software Dependent     Read Only (1)    
"Rating Number"     Software Dependent     None    
"Rated Engine Speed"     Software Dependent     Read Only (1)    
"ECM Identification Parameters"    
"Engine Serial Number"     0XX00000 or XXX00000     Blank     Factory    
"Equipment ID"     17 alphanumeric characters     Blank     Customer    
"Flash File Part Number"     Software Dependent     Read Only (1)    
"Flash File Release Date"     Software Dependent     Read Only (1)    
"ECM Serial Number"     Hardware Dependent     Blank     Read Only (1)    
"Security Access Parameters"    
Total Tattletale     0 to 65535     0     Read Only (1)    
"Engine/Gear Parameters"    
"Low Idle Speed"     600 to 1200 rpm     1200     Customer    
"Engine Accelleration Rate"     5 - 2000 rpm/sec     500     Customer    
"Engine Speed Droop"     0.0 - 8.0 %     "0.0 %"     Customer    
"Droop mode switch"     "Installed" or "Uninstalled"     "Uninstalled"     Customer    
"Droop/Isochronous Switch enable"     "Enabled" or "Disabled"     "Enabled"     Customer    
"Droop mode selection"     "Droop" or "Isochronous"     "Droop"     Customer    
"Governor Gain Factor"     0 - 65,535     47,186     Customer    
"Governor Minumum Stability Factor"     0 - 65,535     2818     Customer    
"Governor Maximum Stability Factor"     0 - 65,535     7864     Customer    
"I/O Configuration Parameters"    
"Fuel Temperature Sensor"     "Installed" or "Uninstalled"     "Uninstalled"     Customer    
"Coolant Level Sensor"     "Installed" or "Uninstalled"     "Uninstalled"     Customer    
"Air Inlet Heater Installation Status"     "Installed" or "Uninstalled"     "Installed"     Customer    
"System Parameters"    
"FLS"     Programmed at the Factory     Factory    
"FTS"     Programmed at the Factory     Factory    

Parameter Worksheet

Table 2
Parameter Worksheet    
Engine Parameters    
"Flash File Part Number"        
"Flash File Release Date"        
"Equipment ID"        
"Engine Serial Number"        
"ECM Serial Number"        
"FLS"        
"FTS"        
"Low Idle Speed"        
"Engine Acceleration Rate"        
"Engine Speed Droop"        
"Droop mode switch"        
"Droop/Isochronous Switch status"        
"Droop mode selection"        
"Governor Gain Factor"        
"Governor Minumum Stability Factor"        
"Governor Maximum Stability Factor"        
"Fuel Temperature Sensor status"        
"Coolant Level Sensor status"        
"Total Tattletale"        
Information from Engine Information Plate    
"Engine Serial Number"        
"FLS"        
"FTS"        

Note: Compare the FLS and the FTS from the ECM with the values that are listed on the Engine Information Plate. The FLS and the FTS should only be changed because of a mechanical change in the engine. The use of the wrong parameters could cause damage to the engine. The use of the wrong parameters may also void the Caterpillar warranty.

Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.