To stop in an emergency:

Mechanical Governor Control:

Pull upward on the hand grip, and move the control to the shutoff position.

Manual Shutoff Control:

Push and hold the control handle until the engine stops.

Woodward UG8 Governor:

Turn the load limit knob to "0".

Woodward PSG Governor:

Move the lever forward against the stop; hold the lever until the engine is stopped.

Mechanical Safety Shutoff Control:

Push and hold the emergency stop button momentarily to allow the overspeed mechanism to trip and start slowing the engine.


NOTICE

This button has a skirt. Do not confuse it with the reset button which is flat. Use this mechanical shutoff button for emergencies only. Do not use it for normal stopping.


Electric Shutoff Solenoid:

Push and hold the ON-OFF-STOP switch in the STOP position until the engine stops.

Air Controls:

Push and hold the ON-OFF-STOP switch in the STOP position until the engine stops.