Usage:
To stop in an emergency:
Mechanical Governor Control:
Pull upward on the hand grip, and move the control to the shutoff position.
Manual Shutoff Control:
Push and hold the control handle until the engine stops.
Woodward UG8 Governor:
Turn the load limit knob to "0".
Woodward PSG Governor:
Move the lever forward against the stop; hold the lever until the engine is stopped.
Mechanical Safety Shutoff Control:
Push and hold the emergency stop button momentarily to allow the overspeed mechanism to trip and start slowing the engine.
NOTICE |
---|
This button has a skirt. Do not confuse it with the reset button which is flat. Use this mechanical shutoff button for emergencies only. Do not use it for normal stopping. |
Electric Shutoff Solenoid:
Push and hold the ON-OFF-STOP switch in the STOP position until the engine stops.
Air Controls:
Push and hold the ON-OFF-STOP switch in the STOP position until the engine stops.