Usage:
5N5692 24V 45A
NOTE: Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.
Polarity ... Negative Ground
Rotation ... Either Direction
Speed for testing (rpm) ... 6500
Output voltage ... 27.5 ± 1.0V
Output (cold) ... 45A
(1) Torque for the ground terminal nut ... 2.3 ± 0.6 N·m (21 ± 5 lb in)
(2) Torque for the pulley nut ... 102 ± 7 N·m (76 ± 5 lb ft)
(3) Torque for the output terminal nut ... 7.1 ± 0.9 N·m (64 ± 8 lb in)
3T6353 Regulator (Inside Alternator)
Voltage setting ... No adjustment
Permissible voltage range ... 26 to 30V
Delco-Remy (27SI)
9L5938 12V 65A
Rotation ... Either Direction
Polarity ... negative ground
Rated output (cold):
2000 rpm ... 46A
5000 rpm ... 58A
Rated output (hot) ... 65A
Output voltage ... 14.0 ± .5V
Field current at 12V and 27°C (80°F) ... 5.2 to 5.8A
(1) Torque for pulley nut ... 100 ± 7 N·m (75 ± 5 lb ft)
(2) Terminal torques:
Torque for battery connection nut ... 3.7 ± 0.8 N·m (32.5 ± 7.5 lb in)
Torque for ground connection nut ... 9.0 ± 3.0 N·m (80 ± 27 lb in)
3T7070 12V 65A
Rotation ... Either Direction
Polarity ... negative ground
Rated output (cold):
2000 rpm ... 52A
5000 rpm ... 72A
Rated output (hot) ... 80A
Output voltage ... 14.0 ± .5V
Field current at 12V and 27°C (80°F) ... 5.2 to 5.8A
(1) Torque for pulley nut ... 100 ± 7 N·m (75 ± 5 lb ft)
(2) Terminal torques:
Torque for battery connection nut ... 3.7 ± 0.8 N·m (32.5 ± 7.5 lb in)
Torque for ground connection nut ... 9.0 ± 3.0 N·m (80 ± 27 lb in)
9L6774 Regulator (Inside Alternator)
Voltage rating ... 12V
Voltage setting ... No Adjustment
Voltage range ... 14.0 ± .5V
Delco-Remy (30SI)
4N3986 24V 60A
NOTE: Load the battery with a carbon pile (6V4930 Battery Load Tester) to get the maximum alternator output.
Polarity ... Negative Ground
Rotation ... Either Direction
Speed for testing (rpm) ... 6500
Output voltage ... 27.5 ± 1.0V
Output (cold) ... 60A
(1) Torque for the pulley nut ... 102 ± 7 N·m (76 ± 5 lb ft)
(2) Torque for the output terminal nut ... 7.1 ± 0.9 N·m (64 ± 8 lb in)
3T6354 Regulator (Inside Alternator)
Voltage setting range ... 26 to 30V
Rated voltage ... 28V
(A) Adjust the voltage with the four-position cap.
Lo ... Low
2 ... Medium Low
3 ... Medium High
Hi ... High