Usage:
914G (7ZM1-UP, 9WM1-UP) Wheel Loaders IT14G (8ZM1-UP, 1WN1-UP) Integrated Toolcarriers
The new 130-7092 Separator Group is now available. Improvements in the 130-7092 Separator Group include a pre-cleaner paper type filter element and the separator group has been moved to a more accessible location. The separator group's new location on the hystat cover group provides enough room to recover fuel when purging the system.
NOTICE |
---|
The water separator should be drained daily or every 10 hours. Failure to drain the water separator can result in fuel injection pump seizure.
|
The new 130-7092 Separator Group replaces the former 4W-2953 Separator Assembly. Both the new separator group and the former separator assembly are found under the 107-4814 Fuel Lines Group.
The following chart and drawing indicates the parts and quantities added to the fuel lines group.
Illustration 1