Usage:
When installing the switch, tighten to a torque of ... 40 ± 5 N·m (29 ± 4 lb ft)
Terminal No. 1 is common.
Terminal No. 2 is normally open.
Terminal No. 3 is normally closed.
6T6651
With a pressure increase, terminal 2 closes and terminal 3 opens at ... 241 ± 28 kPa (35 ± 4 psi)
With a pressure decrease, terminal 2 opens and terminal 3 closes at ... 207 ± 28 kPa (30 ± 4 psi)
9X4276
With a pressure increase, terminal 2 closes and terminal 3 opens at ... 93 ± 20.8 kPa (13.5 ± 3.0 psi)
With a pressure decrease, terminal 2 opens and terminal 3 closes at ... 68.9 ± 20.8 kPa (10.0 ± 3 psi)
When installing the switch, tighten to a torque of ... 35 ± 3 N·m (26 ± 2.2 lb ft)
Terminal A is common.
Terminal B is normally open.
Terminal C is normally closed.
6T6651
With a pressure increase, terminal B closes and terminal C opens at ... 90 ± 21 kPa (13 ± 3 psi)
With a pressure decrease, terminal B opens and terminal C closes at ... 70 ± 21 kPa (10 ± 3 psi)
With a decrease in pressure, the switch must close at a minimum of ... 70 ± 20 kPa (10 ± 3 psi)
With an increase in pressure, the switch must open at a maximum of ... 70 kPa (10 psi)
When installing torque to ... 35 ± 3 N·m (26 ± 2 lb ft)