Procedure to Properly Tighten the Nuts on the Solenoid Studs on Electronic Unit Injectors (EUI){1290, 1408, 1900}
- Engine:Commercial All Diesel
Introduction
This special instruction provides the correct torque for the solenoid studs.
Torque Procedure
Show/hide table
NOTICE |
---|
Incorrect torque applied to the solenoid studs may result in a broken or damaged stud. This damaged stud can leave the injector unusable or more susceptible to failure. |
Show/hide table
Illustration 1 | g03741175 |
- Solenoid studs (1) can be damaged as shown in Illustration 1 when installing an injector.
- In order to prevent damage to solenoid studs (1), tighten the nuts on studs (1) to a torque of 2.2 to 2.6 N·m (19.5 to 23.0 lb in).
Show/hide table
Illustration 2 | g03741150 |
Caterpillar Information System:
C280 Marine Engines NOx Sensor - Test
3512E Tier 4 Final Engines for Land Electric Drilling NRS Exhaust Gas Temperature Is High
C13 Industrial Engine Water in Fuel - Test
C13 Industrial Engine Variable Valve Actuator Response - Test
C13 Industrial Engine Variable Valve Actuator - Test
C175-16 Locomotive Engine NOx Sensor Supply - Test
C13 Industrial Engine Switch Circuits - Test
C13 Industrial Engine Speed/Timing - Test
C13 Industrial Engine Speed Control - Test
C13 Industrial Engine Solenoid Valve - Test
C13 Industrial Engine Shutdown (Ground Level) - Test
C13 Industrial Engine Sensor Supply - Test
Installation of Exhaust Shield Assemblies On Certain G3520C Engines {1059} Installation of Exhaust Shield Assemblies On Certain G3520C Engines {1059}
XQC1200 Power Module Setup
XQC1200 Power Module Coolant (ELC) - Change
C280 Marine Engines DEF Pump Power Supply - Test
2014/10/31 New Recommendations for Starters and Batteries Used on 3516 Engines Operating in China {1401, 1453}
2014/11/26 A New Valve Cover Base Is Used on Certain C15 and C18 Commercial Engines {1120}
XQC1200 Power Module Coolant (DEAC) - Change
XGC1900 Generator Sets Circuit Breakers - Reset
C280 Marine Engines DEF Pump Motor - Test
C27 and C32 Engine for MD6250 and MD6310 Drill Timing - Calibrate
2014/12/05 A New Tube Is Now Used on Certain 3516 Engines {1319}
C7.1-XQ200 Rental Generator Set Maintenance Interval Schedule - Prime