Required Tools | |||
Tool | Part Number | Part Description | Qty |
A | FT-2674(1) | Vacuum Cap | 1 |
(1) | Extension |
Start By:
- Release the hydraulic system pressure. Refer to Disassembly and Assembly, "Hydraulic System Pressure - Release".
NOTICE |
---|
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products. Dispose of all fluids according to local regulations and mandates. |
NOTICE |
---|
Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life. |
Personal injury can result from hydraulic oil pressure and hot oil. Hydraulic oil pressure can remain in the hydraulic system after the engine has been stopped. Serious injury can be caused if this pressure is not released before any service is done on the hydraulic system. Make sure all of the work tools have been lowered to the ground, and the oil is cool before removing any components or lines. Remove the oil filler cap only when the engine is stopped, and the filler cap is cool enough to touch with your bare hand. |
- Open storage box (1) for the window guards.
Show/hide table
Illustration 2 g01571093 - Remove the cap from the hydraulic tank. Install Tooling (A) onto the hydraulic tank. Attach an air supply hose to Tooling (A). Apply
276 to 414 kPa (40 to 60 psi) of air pressure. This procedure will pull vacuum on the hydraulic system.Show/hide tableIllustration 3 g01583453 - Remove the bolts and cover assembly (2).
Show/hide table
Illustration 4 g01583517 - Remove accumulator (3). Remove the O-ring seal from the accumulator.
Illustration 1 | g01571895 |
Required Tools | |||
Tool | Part Number | Part Description | Qty |
A | FT-2674(1) | Vacuum Cap | 1 |
(1) | Extension |
- Install the O-ring seal on the accumulator.
Show/hide table
Illustration 5 g01583517 - Install accumulator (3) .
Show/hide table
Illustration 6 g01583453 - Install cover assembly (2) and the bolts.
Show/hide table
Illustration 7 g01571093 - Remove Tooling (A).
Show/hide table
Illustration 8 g01571895 - Close storage box (1) for the window guards.
- Check the hydraulic oil level. Refer to Operation and Maintenance Manual, "Hydraulic System Oil Level - Check". Refer to Operation and Maintenance Manual, "Lubricant Viscosities". Refer to Operation and Maintenance Manual, "Capacities (Refill)".
Note: Inspect the O-ring seal for wear or for damage. If necessary, replace the O-ring seal.