3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Caterpillar


CID 0263 FMI 03 Sensor Power Supply Voltage Above Normal - Test

Usage:

3516B 1NW



Illustration 1g00573764

Schematic For Sensor Power Supply

Note: The procedures that are used to troubleshoot this diagnostic code may cause additional diagnostic codes to be generated. Find the cause and repair the cause of this diagnostic code before troubleshooting any new diagnostic codes.

This diagnostic code is recorded when the Main Display Module reads the voltage of the sensor supply voltage circuit as above normal. Also, the diagnostic code is recorded when the Main Display Module is shorted to +battery.

  1. Measure the Voltage at the Main Display Module.

    1. Turn the "ECS" switch to the COOLDOWN/STOP position.

    1. Use the 7X-1710 Multimeter Probe to measure the voltage at the Main Display Module from Contact 24 to Contact 2 (ground). Do not disconnect the harness from the Main Display Module.

      Expected Result: The voltage should be 8.0 ± 0.5 DCV.

      Results:

      • OK - The voltage is 8.0 ± 0.5 DCV. The sensor supply voltage is correct. If the SERV CODE indicator remains ON, replace the Main Display Module. For more information, see Testing And Adjusting, "Module - Replace".

      • Not OK - The voltage is not 8.0 ± 0.5 DCV. The sensor supply voltage is not correct. Proceed to Step 2.

  1. Disconnect The Sensors.

    1. The "ECS" switch remains in the COOLDOWN/STOP position.

    1. Disconnect all sensors and senders that receive +8 DCV from the Main Display Module.

    1. Use the 7X-1710 Multimeter Probe to measure the voltage that is from connector contact 2 (ground) to contact 24 of the Main Display Module.

      Expected Result: The voltage should measure 8.0 ± 0.5 DCV.

      Results:

      • OK - The voltage measures 8.0 ± 0.5 DCV. The voltage is correct. One of the sensors or one of the senders has a problem. Individually reconnect each sensor and reconnect each sender while the voltage level is being monitored. The voltage should measure 8.0 ± 0.5 DCV when each component is connected. If the voltage is not 8.0 ± 0.5 DCV the sensor or the sender has a problem. Replace the sensor or replace the sender.

      • Not OK - The sensor supply voltage is not 8.0 ± 0.5 DCV. The sensor supply voltage is not correct. Proceed to Step 3.

  1. Check The Harness For A Short To +Battery.

    1. Turn the "ECS" switch to the OFF/RESET position.

    1. Disconnect all sensors and senders that receive +8 DCV from the Main Display Module.

    1. Disconnect the engine harness from the Main Display Module.

    1. At the engine harness connector for the Main Display Module, measure the resistance from connector contact 24 to contact 1 (+battery).

      Expected Results: The resistance should be greater than 5000 ohms.

      Results:

      • OK - The resistance is greater than 5000 ohms. The harness resistance is correct. The Main Display Module has a problem. Replace the Main Display Module. For more information, see Testing And Adjusting, "Module - Replace".

      • Not OK - The resistance is less than 5000 ohms. The engine harness has a problem. There is a short between ground and the sensor supply voltage circuit in the engine harness. Repair the engine harness or replace the engine harness.

Caterpillar Information System:

3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0248 FMI 02 Cat Data Link Incorrect - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0177 FMI 08 Temperature Sensor (Transmission Oil) Abnormal Signal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0175 FMI 04 Temperature Sender (Engine Oil) Voltage Below Normal - Test
3406C (PEEC III) Truck Engines Compression Brake
3412E and C30 Marine Engines Air Inlet And Exhaust System
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0172 FMI 04 Temperature Sender (Inlet Air) Voltage Below Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0127 FMI 08 Pressure Sensor (Transmission Oil) Abnormal Signal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0096 FMI 03 Level Switch (Fuel) Voltage Above Normal - Test
330B Excavator Machine System Specifications Track Roller (Single Flange)
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Troubleshooting Diagnostic Codes
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Accessing Diagnostic Information
3412E and C30 Marine Engines Basic Block
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0263 FMI 04 Sensor Power Supply Voltage Below Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0271 FMI 03 Alarm (Action) Voltage Above Normal - Test
C-10 and C-12 Industrial Engines Engine Oil Cooler
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0271 FMI 05 Alarm (Action) Current Below Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0271 FMI 06 Alarm (Action) Current Above Normal - Test
3606 and 3608 Engines Vibration Damper - Dual
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0819 FMI 02 Display Data Link Incorrect - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0821 FMI 03 Display Power Supply Voltage Above Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0821 FMI 04 Display Power Supply Voltage Below Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Alert Indicator - Troubleshoot
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System LH/RH Switch - Troubleshoot
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Scroll Switch - Troubleshoot
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.