Electronic Modular Control Panel II (EMCP II) for EUI Engines Caterpillar


CID 445 FMI 12 Run Relay Failed - Test

Usage:

3516B 1NW



Illustration 1g00488507

System Schematic For Run Relay (RR)

The contacts for the run relay (RR) are available for use by the customer. The RR is located within the relay module. The GSC activates the run relay (RR) during engine cranking and running.

Note: Whenever the GSC activates the RR, "K5" is shown on the lower display. "K5" is also shown on the lower display when the GSC attempts to activate the crank terminate relay. When the RR is not activated, "K5" is not shown.

Procedure

The possible cause of this diagnostic code is an open coil or a shorted coil of the RR.

The following response is the system response to this fault while the RR is activated:

  • If a CID 445 occurs, then any equipment that is connected to RM-24 is deactivated. Also, any equipment that is connected to RM-23 is activated.

The following response is the system response to this fault while the RR is not activated:

  • If a CID 445 occurs, then any equipment that is connected to RM-24 is not activated. Also, any equipment that is connected to RM-23 remains activated.

The GSC treats this diagnostic code as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. Also, the active alarm faults are shown when the ECS is in any position except the OFF/RESET position. Clear the diagnostic code from the fault log after troubleshooting is complete.

  1. Check the status of the diagnostic code (Active/Inactive).

    1. Turn the ECS to OFF/RESET and then turn the ECS to STOP.

    1. Press the alarm codes key.

    1. Observe the upper display. Check that a CID 445 FMI 12 is showing.

    1. If this diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing.

      Expected Result: A CID 445 FMI 12 is showing as a active fault or an inactive fault.

      Results:

      • No - A CID 445 FMI 12 has not occurred (NOT active and NOT inactive). STOP.

      • Yes - A CID 445 FMI 12 is active or inactive. Proceed to 2.

  1. Check internal cable of relay module.

    Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC housing. See Testing And Adjusting, "Relay Module Replace".

    1. Turn the ECS to OFF/RESET.

    1. Temporarily, remove the relay module from the GSC. See Testing And Adjusting, "Relay Module - Replace".

    1. Check the cable that attaches the relay module to the GSC.

      Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged.

      Results:

      • OK - Reassemble the relay module to the GSC. Proceed to 3.

      • NOT OK - Replace the connector clamp if it is missing. If the cable is damaged, replace the GSC. STOP.

  1. Perform a functional check for the RR.

    1. Turn the ECS to OFF/RESET.

    1. Disconnect all wires from RM-24 of the relay module. Remove the fuse "F4" from the relay module.

    1. At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be greater than 5000 ohms.

    1. Turn the ECS to the START position. Make sure that "K5" is showing on the lower display.

    1. At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be less than 5 ohms.

      Expected Result: For 3.c, the resistance should be greater than 5000 ohms. For 3.e, the resistance should be less than 5 ohms.

      Results:

      • OK - It is likely that a temporary bad electrical connection existed and this troubleshooting procedure corrected it. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.

      • NOT OK - Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.

Caterpillar Information System:

3406E On-Highway Engine Electronic Unit Injector Sleeve - Install
3306C Engines for Caterpillar Built Machines Engine Design
3600 Heavy Fuel Engines Exhaust Manifold - Inspect
3612 and 3616 Fast Vessel Engines Alarms and Shutoffs
Electronic Modular Control Panel II (EMCP II) for EUI Engines CID 444 FMI 12 Starting Motor Relay Failed - Test
3304B and 3306B Engines for Caterpillar Built Machines Crankshaft Front Seal - Install
G3612 and G3616 Engines Air Inlet and Exhaust System
Electronic Modular Control Panel II (EMCP II) for EUI Engines CID 443 FMI 12 Crank Termination Relay Failed - Test
3406E On-Highway Engine Fuel Transfer Pump - Remove
P16, P20, P25, P28, P40 and P60 Pulverizers Pulverizer Cylinder
Electronic Modular Control Panel II (EMCP II) for EUI Engines CID 441 FMI 12 Electronic Governor Relay Failed - Test
3306C Truck Engine Crankshaft Front Seal - Remove
3406E On-Highway Engine Electronic Unit Injector Sleeve - Remove
Electronic Modular Control Panel II (EMCP II) for EUI Engines CID 446 FMI 12 Air Shutoff Relay Failed - Test
3306B Industrial Engine Fuel Injection Pump
Electronic Modular Control Panel II (EMCP II) for EUI Engines CID 447 FMI 12 Fuel Control Relay Failed - Test
G3612 and G3616 Engines Engine Timing Procedures
Electronic Modular Control Panel II (EMCP II) For MUI Engines CID 500 FMI 12 EMCP Electronic Control (Generator Set) Failed - Test
3406C Engines for Caterpillar Built Machines Camshaft
Electronic Modular Control Panel II (EMCP II) for EUI Engines CID 566 FMI 7 Unexpected Shutdown Improper Mechanical Response - Test
3406C Engines for Caterpillar Built Machines Cylinder Head Valves
3306B Industrial Engine Fuel Injection Pump Housing
C-10 and C-12 Truck Engines Crankshaft
Electronic Modular Control Panel II (EMCP II) for EUI Engines CID 590 FMI 9 Engine Electronic Control Module Abnormal Update - Test
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.