Usage:
9L5938 12V 65A
Rotation ... CW or CCW.
Polarity ... negative ground.
Rated output (cold):
2000 rpm ... 46A
5000 rpm ... 58A
Rated output (hot) ... 65A
Output voltage ... 14.0 ± .5V
Field current at 12V and 27°C (80°F) ... 5.2 to 5.8A
(1) Torque for pulley nut ... 100 ± 7 N·m (75 ± 5 lb ft)
(2) Terminal torques:
Torque for battery connection nut ... 3.7 ± 0.8 N·m (32.5 ± 7.5 lb in)
Torque for ground connection nut ... 9.0 ± 3.0 N·m (80 ± 27 lb in)
3T7070 12V 65A
Rotation ... CW or CCW.
Polarity ... negative ground.
Rated output (cold):
2000 rpm ... 52A
5000 rpm ... 72A
Rated output (hot) ... 80A
Output voltage ... 14.0 ± .5V
Field current at 12V and 27°C (80°F ... 5.2 to 5.8A
(1) Torque for pulley nut ... 100 ± 7 N·m (75 ± 5 lb ft)
(2) Terminal torques:
Torque for battery connection nut ... 3.7 ± 0.8 N·m (32.5 ± 7.5 lb in)
Torque for ground connection nut ... 9.0 ± 3.0 N·m (80 ± 27 lb in)
Delco-Remy 20-SI Alternator
5N5692 24V 45A
Rotation ... CW or CCW.
Polarity ... negative ground.
Output when cold:
2500 rpm ... 12A
6500 rpm ... 45A
Rated output (hot) ... 45A
Field current at 24V and 27°C (80°F) ... 3.3 to 3.8A
Torque for positive output terminal nut ... 6.2 to 8.0 N·m (55 to 71 lb in)
(1) Torque for five ground screws ... 1.7 to 2.9 N·m (15 to 26 lb in)
(2) Torque for pulley nut ... 100 ± 7 N·m (75 ± 5 lb ft)
Delco-Remy 30-SI Alternator
4N3986 24V 60A
Rotation ... CW or CWW.
Polarity ... Insulated ground.
Output when cold:
2600 rpm ... 46A
6500 rpm ... 60A
Rated output (hot) ... 60A
Field current at 24V and 27°C (80°F) ... 2.5 to 2.8A
(1) Torque for pulley nut ... 100 ± 7 N·m (75 ± 5 lb ft)
(2) Torque for output terminal nuts ... 6.8 to 8.0 N·m (60 to 72 lb in)