Usage:
This procedure shows how to set the Fluke 90 Series ScopeMeters for detonation analysis. Some of the following steps apply only to the Fluke 97. If using a Fluke 93 or FLUKE 95 ScopeMeter, simply skip those steps which do not apply.
1. Press the
key.
2. Press the
key.
3. Press the PROBE CAL soft key.
4. Using the UP/DOWN Arrow keys, select the 10:1 display under Channel A. Press the ENTER soft key.
5. Press the PROBE CAL soft key.
6. Using the UP/DOWN Arrow keys, select the 10:1 display under Channel B. Press the ENTER soft key.
7. Press the PICTURE soft key.
8. Use the UP/DOWN arrow keys and the ENTER soft key to select DOT JOIN and DOTSIZE 1. These selections are active when the box before the text is LARGE.
9. Press the GRID soft key.
10. Use the UP/DOWN arrow keys to select FULL. Press the ENTER soft key.
11. Press the BACK LIGHT soft key. Use of backlighting is recommended only when the scope is powered by the adapter.
12. Use the UP/DOWN arrow keys to adjust the screen contrast for best viewing.
13. Press the
key.
14. Press the SINGLE/RECURRENT soft key to select RECURRENT.
15. Press the FREE RUN soft key to deselect FREE RUN.
16. Press the CAPTURE soft key to select 20 DIV.
17. Press the MIN MAX on A so it is not selected.
18. Press the
key.
19. Press the A INVERT key to select A.
20. Press the B INVERT key to select B.
21. Press the
key.
22. Press the EXT/A/B soft key to select EXT.
23. Press the +SLOPE/-SLOPE soft key to select -SLOPE.
24. Press the LEVEL soft key to select 2V.
25. Press the DELAY soft key to open the window.
26. Use the UP/DOWN arrow keys to select TIME DELAY. Press the ENTER soft key.
27. Press the DELAY ZERO soft key.
28. Press the
key to select GND.
29. Press the
(CHANNEL A) to move the trace to the second grid line from the bottom.
30. Press the
(CHANNEL A) to select a vertical scale of 10V.
31. Press the
key to select DC Coupling.
32. Press the
key to select GND.
33. Press the
(CHANNEL B) to move the trace to the second grid line from the top.
34. Press the
(CHANNEL B) to select a vertical scale of 1V.
35. Press the
key to select AC Coupling.
36. Press the
key to select a horizontal time scale of 10 ms/DIV.