SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Caterpillar


Setup Procedure For Fluke 90 Series

Usage:

This procedure shows how to set the Fluke 90 Series ScopeMeters for detonation analysis. Some of the following steps apply only to the Fluke 97. If using a Fluke 93 or FLUKE 95 ScopeMeter, simply skip those steps which do not apply.

1. Press the

key.

2. Press the

key.

3. Press the PROBE CAL soft key.

4. Using the UP/DOWN Arrow keys, select the 10:1 display under Channel A. Press the ENTER soft key.

5. Press the PROBE CAL soft key.

6. Using the UP/DOWN Arrow keys, select the 10:1 display under Channel B. Press the ENTER soft key.

7. Press the PICTURE soft key.

8. Use the UP/DOWN arrow keys and the ENTER soft key to select DOT JOIN and DOTSIZE 1. These selections are active when the box before the text is LARGE.

9. Press the GRID soft key.

10. Use the UP/DOWN arrow keys to select FULL. Press the ENTER soft key.

11. Press the BACK LIGHT soft key. Use of backlighting is recommended only when the scope is powered by the adapter.

12. Use the UP/DOWN arrow keys to adjust the screen contrast for best viewing.

13. Press the

key.

14. Press the SINGLE/RECURRENT soft key to select RECURRENT.

15. Press the FREE RUN soft key to deselect FREE RUN.

16. Press the CAPTURE soft key to select 20 DIV.

17. Press the MIN MAX on A so it is not selected.

18. Press the

key.

19. Press the A INVERT key to select A.

20. Press the B INVERT key to select B.

21. Press the

key.

22. Press the EXT/A/B soft key to select EXT.

23. Press the +SLOPE/-SLOPE soft key to select -SLOPE.

24. Press the LEVEL soft key to select 2V.

25. Press the DELAY soft key to open the window.

26. Use the UP/DOWN arrow keys to select TIME DELAY. Press the ENTER soft key.

27. Press the DELAY ZERO soft key.

28. Press the

key to select GND.

29. Press the

(CHANNEL A) to move the trace to the second grid line from the bottom.

30. Press the

(CHANNEL A) to select a vertical scale of 10V.

31. Press the

key to select DC Coupling.

32. Press the

key to select GND.

33. Press the

(CHANNEL B) to move the trace to the second grid line from the top.

34. Press the

(CHANNEL B) to select a vertical scale of 1V.

35. Press the

key to select AC Coupling.

36. Press the

key to select a horizontal time scale of 10 ms/DIV.

Caterpillar Information System:

SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Fluke ScopeMeter Settings
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS General Oscilloscope Settings
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Scope Requirements And Settings
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Introduction
3054 TRUCK ENGINE Troubleshooting Problem Lists
3054 TRUCK ENGINE Troubleshooting Problem Charts
3054 TRUCK ENGINE Testing & Adjusting
3054 TRUCK ENGINE Systems Operation
3406C INDUSTRIAL ENGINE Testing & Adjusting
3406C INDUSTRIAL ENGINE Systems Operation
3406C INDUSTRIAL ENGINE Pressure Regulating Valve
3406C INDUSTRIAL ENGINE Air Starting Motor
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Scope Probe Connections
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Time Delay Values For Cylinder Location
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Time Delay Procedure For Fluke 90 Series.
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS G3616 Time Delay Values
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS G3612 Time Delay Values
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS G3608 Time Delay Values
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS G3606 Time Delay Values
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Fluke Operation
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS Detonation Sensor Signal Analysis
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS False Detonation Signals And Valve Noise
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS G3616 Odd Bank Cam Timing Events
SUPPLEMENT FOR G3600 ENGINES DETONATION AYALYSIS G3616 Even Bank Cam Timing Events
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.