3406C INDUSTRIAL ENGINE Caterpillar


Water Temperature Gauges

Usage:

7W2061

7W2061 Gauge 12V; Use with 5L7443 Sending Unit

Range ... 38 to 116°C (100 to 240°F)

Test voltage ... 13.8 ± 0.3V

Tolerance ... ±0.76 mm (.03 in)

NOTE: Measure tolerance from the end of the pointer to the centerline of the mark on the face of the indicator.

7W2060

7W2060 Gauge 24-32V; Use with 5L7442 Sending Unit

Range ... 38 to 116°C (100 to 240°F)

Test voltage ... 27.2 ± 0.3V

Tolerance ... ±0.76 mm (.03 in)

NOTE: Measure tolerance from the end of the pointer to the centerline of the mark on the face of the indicator.

NOTE: For 32V systems the 5L7441 resistor (65 ohms) is used with this gauge.