3406C INDUSTRIAL ENGINE Caterpillar


Starting Motor

Usage:

6V0927 24V

Rotation as viewed from drive end:

6V0511 ... Counterclockwise

6V0927 ... Clockwise

No load conditions at 25°C (77°F):

Speed ... 6950 ± 1650 rpm

Current ... 115 ± 25A

Voltage ... 23V

Clearance between pinion and housing (pinion clearance) ... 9.1 mm (0.36 ± 0.03 in)

(1) Torque for large terminal nuts ... 30.5 ± 3.5 N· (269 ± 31 lb in)

(2) Torque for small terminal nuts ... 2.25 ± 0.25 N· (20 ± 2 lb in)

Solenoid

Current consumption (draw):

Pull in windings at 20V ... 49.3 ± 3.3A

Hold in windings at 20V ... 6.8A max

9X4452 24V

Voltage ... 24V

Rotation-viewed from drive end ... clockwise

(1) Torque for 1/2 - 13 terminal nuts ... 27 to 34 N· (20 to 25 lb ft)

(2) Torque for 10 - 32 terminal nuts ... 2.25 ± .25 N· (19.912 ± 2.212 lb in)

(3) Tighten nut to a torque of ... 17.5 ± 2.5 N· (12.87 ± 1.84 lb ft)

(4) Tighten nut to a torque of ... 1.5 ± 0.4 N· (13.27 ± 3.54 lb in)

No load speed at 25°C (77°F) ... 3300 rpm minimum

No load current consumption (draw) at 23.5V ... 80A maximum

Pull-in current at 24V ... 103A

Hold-in current at 24V ... 19A maximum

8C3644 24V, 8C3649 24V

(1) Torque for terminal nuts ... 30 ± 3 N· (22 ± 2 lb ft)

(2) Torque for screws holding nose housing to lever housing ... 20 ± 2 N· (177 ± 18 lb in)

Clearance between pinion and housing pinion clearance) ... 8.3 to 9.9 mm (.33 to .39 in)

Rotation as seen from drive end ... Clockwise

No load conditions at 25°C (77°F):

Speed (rpm) ... 5500 to 8000

Current (amps) ... 50 to 85A

Voltage ... 20.0V

7T0794 24V, 7T0795 24V

Rotation as seen from drive end ... Clockwise

No load conditions at 25°C (77°F):

Speed (rpm) ... 5500 minimum

Current (amps) ... 140A maximum

Voltage ... 24.0V

(1) Intermediate housing.

(2) Bracket.

(3) Torque for small solenoid terminal nut ... 2.25 ± 0.25 N· (20 ± 2 lb in)

(4) Torque for large terminal nuts ... 30 ± 3 N· (265.5 ± 26.5 lb in)

(5) Bolt. Tighten to a torque ... 8.5 ± 1.5 N· (75 ± 13 lb in)

The pinion clearance is correct when the solenoid position dimension (X) is 62.50 + 0.20 - 0.50 mm (2.461 + .008 - .020 in) from intermediate housing (1). The following procedure is used to adjust the solenoid position:

a. Loosen bolts (5) and move the solenoid until distance (X) is correct. Bracket (2) has elongated holes.

b. Tighten bolts (5) after the adjustments is correct to a torque of ... 8.5 ± 1.5 N· (75 ± 13 lb in)