Gauges For Water Temperature

Usage:

5L7444 Gauge; Use with 5L7442 Sending Unit.

Rating ... 24V

Temperature range ... 100 to 240° F(38 to 115° C)

Calibration test at 28.5V (30° mounting):

100° F (38° C) ... 3388 Ohms

170° F (77° C) ... 1050 Ohms

240° F (115° C) ... 460 Ohms