Usage:
1. Remove wire connector (1) from retainer clip. Disconnect wiring (2) at the connector. Remove seal and lockwire from the bolts.
2. Remove two bolts (3). Remove cover (4).
3. Remove allen screw (5) and nut (6). Remove exhaust recirculation switch assembly (7).
4. Remove load stop pin (8). Remove gasket (9). Inspect the gasket and make a replacement if necessary.
Install Exhaust Recirculation Switch Assembly
1. Install a new gasket (2) if necessary. Install load stop pin (1).
2. Put the exhaust recirculation switch assembly (3) in position and install the nut and allen screw that hold it.
3. Install switch assembly cover (6) with two bolts (5) that hold it. Install lockwire and seal on the bolts. Connect wiring (4) at connector and then put the connector in position in the retainer clip.