Current consumption (draw):
Current pull in windings at 5V ... 10 to 11.5 A
Current pull in windings at 20 to 24V ... 40 to 55.2 A
Current hold in windings at 20 to 24V ... 8.2 A
7L6586 12V (Delco-Remy Number 1119879)
Current consumption (draw):
Current pull in windings at 5V ... 21.3 to 35.7 A
Current pull in windings at 10 to 12V ... 62.6 to 85.7 A
Current hold in windings at 10V ... 14.3 to 15.4 A
Current hold in windings at 10 to 12V ... 14.3 to 18.5 A
4M1812 and 7L6586
(1) 4M1815 Spring for contact release:
Length under test force ... .42 in.(10.7 mm)
Test force ... 8.5 to 9.5 lb.(3.9 to 4.3 kg)
Free length after test ... .83 ± .015 in.(21.1 ± 0.38 mm)
Outside diameter ... .875 ± .010 in.(22.23 ± 0.25 mm)
(2) 9M7609 or 4M1856 Spring to return the clutch lever:
Length under test force ... 1.56 in.(39.6 mm)
Test force ... 14 ± 5 lb.(6.35 ± 0.23 kg)
Free length after test ... 2.79 in.(70.9 mm)
Outside diameter ... 1.393 ± .015 in.(35.38 ± 0.38 kg)
(3) Torque for terminal screws ... 16 to 30 lb. in.(18.4 to 35.0 cm.kg)