Usage:
32V-18A-DR 1119286-E
(5L7690)
1 Cutout relay
Air gap ... .017 in.0,43 mm
Point gap ... .032 in0,81 mm
Voltage closing range ... 31.3-35.331,3-35,3
2 Current regulator
Air gap ... .075 in.1,9 mm
Current setting range (amp.) ... 16-2016-20
3 Voltage regulator
Air gap ... .060 in.1,52 mm
Voltage setting range @ 85°F. (29°C.) ... 36.8-38.836,8-38,8
4 Torque mounting bolt ... 36±6 lb. in.41±7,0 cm.kg
12V-24A-DR 1119247-E
(8M8809)
1 Cutout relay
Air gap ... .020 in.0,50 mm
Point gap ... .020 in.0,50 mm
Voltage closing range ... 11.8-13.511,8-13,5
2 Current regulator
Air gap ... .075 in.1,9 mm
Current setting range (amp.) ... 22-2622-26
3 Voltage regulator
Air gap ... .060 in.1,52 mm
Voltage setting range @ 85°F. (29°C.) ... 14.2-15.214,2-15,2
4 Torque mounting bolt ... 36±6 lb. in.41±7,0 cm.kg
24V-18A-DR 1119206-E
(6L4677)
1 Cutout relay
Air gap ... .017 in.0,43 mm
Point gap ... .032 in.0,81 mm
Voltage closing range ... 24-2724-27
2 Current regulator
Air gap ... .075 in.1,9 mm
Current setting range (amp.) ... 16-2016-20
3 Voltage regulator
Air gap ... .060 in.1,5 mm
Voltage setting range @ 85°F. (29°C.) ... 27.5-29.527,5-29,5
4 Torque mounting bolt ... 36±6 lb. in.41±7,0 cm.kg
24V-15A-DR 1119233
(8H5875)
1 Cutout relay
Air gap ... .017 in.0,43 mm
Point gap ... .032 in.0,81 mm
Voltage closing range ... 24-2724-27
2 Current regulator
Air gap ... .075 in.1,9 mm
Current setting range (amp.) ... 13.5-16.513,5-16,5
3 Voltage regulator
Air gap ... .075 in.1,9 mm
Point gap ... .016 in.0,41 mm
Voltage setting range @ 85°F. (29°C.) ... 27.5-29.527,5-29,5