Usage:
(1) Torque for terminal nuts ... 14 ± 3 lb. in.(16 ± 3.5 cm.kg)
(2) Initial distance between shaft shoulder and plate ... .70 in.(17,8 mm)
If necessary, make more adjustment after test.
(3) Distance of plunger travel [start with dimension of .44 in. (11,2 mm) at (4)] ... .62 in.(15,7 mm)
Current consumption (draw):
Pull in winding at 9V ... 5.5 to 6.3 A
Pull in winding at 20 to 24V ... 14 to 16.5 A
Hold in winding at 24V ... maximum .45 A
3L2871 24V or 32V (Delco-Remy Number 1119817)
Current pull in windings at 20 V ... 3.9 to 4.2 A
Current pull in windings at 20 to 24 V ... 3.9 to 5.1 A
Current hold in windings at 20 to 24 V ... .5 A
(1) Torque for terminal nuts ... 14 ± 3 lb. in.(16 ± 3,5 cm.kg)
(2) Distance from face of solenoid to center of hole in link when plunger is .75 in. (19,1 mm) from face of solenoid ... 6.12 in.(155,4 mm)
(3) Travel of plunger [starting from a point .75 in. (19,1 mm) from face of solenoid] ... .50 in.(12,7 mm)
(4) Distance from face of plunger to face of solenoid ... .75 in.(19,1 mm)