- Photovoltaic
- PVT110 (S/N: TF21-UP)
- PVT115 (S/N: TF51-UP)
- PVT117 (S/N: TF71-UP)
- PVT120 (S/N: GH81-UP; TF81-UP)
- PVT115 (S/N: TF51-UP)
Introduction
This Special Instruction provides information regarding the compatible inverters without Galvanic Isolation for Cat® PVT 110 and PVT 110 ARC Photovoltaic modules.
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.
Safety Section
Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.
A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.
Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.
Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Ensure that any tool, procedure, work method, or operating technique you use that is not recommended by Caterpillar is safe.
Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility. |
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage. |
When removing a major component or attachment, ensure that it is properly blocked or secured before removing mounting hardware. An assembly that is disconnected without proper blocking may shift or fall, resulting in serious injury or death of personnel or machine damage. |
Personal injury or death can result from improper maintenance procedures. To avoid injury or death, follow the procedures exactly as stated below. |
Personal injury can result from improper handling of chemicals. Make sure you use all the necessary protective equipment required to do the job. Make sure that you read and understand all directions and hazards described on the labels and material safety data sheet of any chemical that is used. Observe all safety precautions recommended by the chemical manufacturer for handling, storage, and disposal of chemicals. |
Climbing equipment may be required to access this service point. Refer to the Operation and Maintenance Manual, "Mounting and Dismounting" topic for safety information. |
Before servicing/performing maintenance on the machine, electrical power must be physically disconnected; battery plugs must be disconnected from the batteries, or the trailing cable must be unplugged, and warning tags and padlocks shall be applied by a certified electrician. Certified electricians shall perform or direct any electrical work, including any energized testing, repair work in controllers, motors, or other approved compartments, and shall insure that all compartments are properly closed and inspected prior to re-energization. All applicable lock out and tag out procedures must be followed. |
Do not operate the machine if any guards or covers are missing or inadequately secured. Personnel could be seriously injured or machine damage may occur. |
Observe the safe working load limits of all lifting and blocking devices and keep a safe distance from suspended/blocked loads. Personnel may be seriously injured or killed by falling loads. |
List of Compatible Inverters without Galvanic Isolation
Manufacturer | Series | Type | VOC Max | External Remarks | FS2 | FS3 | FS4 |
---|---|---|---|---|---|---|---|
ABB | PVS 300-TL | 3300W-2 | 900 | - | 9 | 13 | 9 |
4000W-2 | 900 | - | 9 | 13 | 9 | ||
4600W-2 | 900 | - | 9 | 13 | 9 | ||
6000W-2 | 900 | - | 9 | 13 | 9 | ||
8000W-2 | 900 | - | 9 | 13 | 9 | ||
Advanced Energy | 3TL | 3TL 40 | 1000 | - | 10 | 15 | 10 |
AEG Power Solutions | Protect PV | .250 | 1,000 | - | 10 | 15 | 10 |
.500 | 1,000 | - | 10 | 15 | 10 | ||
10 | 1,000 | - | 10 | 15 | 10 | ||
12,5 | 1,000 | - | 10 | 15 | 10 | ||
15 | 1,000 | - | 10 | 15 | 10 | ||
2000 | 450 | - | 4 | 6 | 4 | ||
2800 | 500 | - | 5 | 7 | 5 | ||
4600 | 750 | - | 7 | 11 | 7 | ||
8 | 1,000 | - | 10 | 15 | 10 | ||
630 | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
800 | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
Aros | Sirio | K533 High Voltage-MT | 880 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 8 | 13 | 8 |
Bonfiglioli | RPS TL | 0950 | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 |
1780 | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
Conergy AG | IPG S | 3S | 940 | - | 9 | 14 | 9 |
4S | 940 | - | 9 | 14 | 9 | ||
5S | 940 | - | 9 | 14 | 9 | ||
IPG T | 11 T | 1,000 | - | 10 | 15 | 10 | |
15 T | 1,000 | - | 10 | 15 | 10 | ||
8 T | 1,000 | - | 10 | 15 | 10 | ||
Danfoss Solar Inverters A/S | TripleLynx | 10 K | 1,000 | - | 10 | 15 | 10 |
12.5k | 1,000 | - | 10 | 15 | 10 | ||
15K | 1,000 | - | 10 | 15 | 10 | ||
8k | 1,000 | - | 10 | 15 | 10 | ||
Delta Energy Systems | Solivia | 15 TL | 1,000 | - | 10 | 15 | 10 |
20 TL | 1,000 | - | 10 | 15 | 10 | ||
RPI | RPI-M20 A | 1000 | - | 10 | 15 | 10 | |
RPI402-1D | 450 | - | 4 | 6 | 4 | ||
Diehl Ako Stiftung & Co. KG | Platinum | 11000 TL3 | 1,000 | - | 10 | 15 | 10 |
13000 TL | 880 | - | 8 | 13 | 8 | ||
16000 TL | 880 | - | 8 | 13 | 8 | ||
19000 TL | 880 | - | 8 | 13 | 8 | ||
22000 TL | 880 | - | 8 | 13 | 8 | ||
4300 TL | 880 | - | 8 | 13 | 8 | ||
4800 TL | 880 | - | 8 | 13 | 8 | ||
5300 TL | 880 | - | 8 | 13 | 8 | ||
6300 TL | 880 | - | 8 | 13 | 8 | ||
7200 TL | 880 | - | 8 | 13 | 8 | ||
Eaton Corporation | Power Xpert Solar | 1500 kW | 1000 | - | 10 | 15 | 10 |
1670 kW | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
Efacec Renewables | EFACEC | PV500 | 1000 | - | 10 | 15 | 10 |
Effekta Regeltechnik GmbH | ES | 3300 | 500 | - | 5 | 7 | 5 |
4200 | 500 | - | 5 | 7 | 5 | ||
5000 | 500 | - | 5 | 7 | 5 | ||
Emerson | SPV | 1060 | 1,000 | - | 10 | 15 | 10 |
1200 | 1,000 | - | 10 | 15 | 10 | ||
1410 | 1,000 | - | 10 | 15 | 10 | ||
145 | 1,000 | - | 10 | 15 | 10 | ||
1500 | 1,000 | - | 10 | 15 | 10 | ||
1590 | 1,000 | - | 10 | 15 | 10 | ||
175 | 1,000 | - | 10 | 15 | 10 | ||
1800 | 1,000 | - | 10 | 15 | 10 | ||
2100 | 1,000 | - | 10 | 15 | 10 | ||
2400 | 1,000 | - | 10 | 15 | 10 | ||
248 | 1,000 | - | 10 | 15 | 10 | ||
2700 | 1,000 | - | 10 | 15 | 10 | ||
300 | 1,000 | - | 10 | 15 | 10 | ||
350 | 1,000 | - | 10 | 15 | 10 | ||
600 | 1,000 | - | 10 | 15 | 10 | ||
700 | 1,000 | - | 10 | 15 | 10 | ||
880 | 1,000 | - | 10 | 15 | 10 | ||
900 | 1,000 | - | 10 | 15 | 10 | ||
Fronius International GmbH | IG TL | 3.0 | 850 | - | 8 | 12 | 8 |
3.6 | 850 | - | 8 | 12 | 8 | ||
4.0 | 850 | - | 8 | 12 | 8 | ||
5.0 | 850 | - | 8 | 12 | 8 | ||
GE Solar | PSC | 800 MV-L-QC | 1300 | - | 10 | 15 | 10 |
GEFRAN S.p.A | Radius Industrial | APV250 K-TL | 1000 | - | 10 | 15 | 10 |
APV270 K-TL | 1000 | - | 10 | 15 | 10 | ||
APV330 K-TL | 1000 | - | 10 | 15 | 10 | ||
APV660 K-TL | 1000 | - | 10 | 15 | 10 | ||
Growatt New Energy | Growatt | 3600MTL-US | 600 | - | 6 | 9 | 6 |
4200MTL-US | 600 | - | 6 | 9 | 6 | ||
5000MTL-US | 600 | - | 6 | 9 | 6 | ||
Hitachi Hi-Rel Power Electronics Pvt. Ltd. | Solar PCS | 250 kW | 1000 | - | 10 | 15 | 10 |
500 kW | 1000 | - | 10 | 15 | 10 | ||
630 kW | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
Huawei Technologies Co. LTD. | SUN2000 | 8KTL | 1000 | - | 10 | 15 | 10 |
10 KTL | 1000 | - | 10 | 15 | 10 | ||
12KTL | 1000 | - | 10 | 15 | 10 | ||
15KTL | 1000 | - | 10 | 15 | 10 | ||
17KTL | 1000 | - | 10 | 15 | 10 | ||
20 KTL | 1000 | - | 10 | 15 | 10 | ||
23KTL | 1000 | - | 10 | 15 | 10 | ||
28KTL | 1000 | - | 10 | 15 | 10 | ||
IBC Solar AG | ServeMaster | 10000TL | 1,000 | - | 10 | 15 | 10 |
12500TL | 1,000 | - | 10 | 15 | 10 | ||
15000TL | 1,000 | - | 10 | 15 | 10 | ||
8000TL | 1,000 | - | 10 | 15 | 10 | ||
Ingeteam GmbH | IngeconSun Lite | 2.5 TL | 550 | - | 5 | 8 | 5 |
3 TL | 550 | - | 5 | 8 | 5 | ||
3.3 TL | 550 | - | 5 | 8 | 5 | ||
3.68 TL | 550 | - | 5 | 8 | 5 | ||
3.8 TL | 550 | - | 5 | 8 | 5 | ||
4.6 TL | 550 | - | 5 | 8 | 5 | ||
5 TL | 550 | - | 5 | 8 | 5 | ||
6 TL | 550 | - | 5 | 8 | 5 | ||
IngeconSun Power Max | 100TL | 900 | - | 9 | 13 | 9 | |
125TL | 900 | - | 9 | 13 | 9 | ||
250TL | 900 | - | 9 | 13 | 9 | ||
315TL | 900 | - | 9 | 13 | 9 | ||
375TL | 900 | - | 9 | 13 | 9 | ||
470TL | 900 | - | 9 | 13 | 9 | ||
500TL | 900 | - | 9 | 13 | 9 | ||
625TL | 900 | - | 9 | 13 | 9 | ||
630 HE TL | 900 | - | 9 | 13 | 9 | ||
IngeconSun Smart | 10 TL | 550 | - | 5 | 8 | 5 | |
12.5 TL | 550 | - | 5 | 8 | 5 | ||
15 TL | 550 | - | 5 | 8 | 5 | ||
18 TL | 550 | - | 5 | 8 | 5 | ||
KACO Gerätetechnik GmbH | Powador | 10.0 TL3 | 1,000 | - | 10 | 15 | 10 |
12.0 TL3 | 1,000 | - | 10 | 15 | 10 | ||
14.0 TL3 | 1,000 | - | 10 | 15 | 10 | ||
25000xi | 800 | - | 8 | 12 | 8 | ||
25000xi Park | 800 | - | 8 | 12 | 8 | ||
2500xi | 800 | - | 8 | 12 | 8 | ||
30.0 TL3 | 1,000 | - | 10 | 15 | 10 | ||
30000xi | 800 | - | 8 | 12 | 8 | ||
30000xi Park | 800 | - | 8 | 12 | 8 | ||
3200 | 800 | - | 8 | 12 | 8 | ||
33.0 TL3 | 1,000 | - | 10 | 15 | 10 | ||
33000xi | 800 | - | 8 | 12 | 8 | ||
33000xi Park | 800 | - | 8 | 12 | 8 | ||
3500xi | 800 | - | 8 | 12 | 8 | ||
36.0 TL3 | 1,000 | - | 10 | 15 | 10 | ||
3600xi | 800 | - | 8 | 12 | 8 | ||
37.5 TL3 | 1,000 | - | 10 | 15 | 10 | ||
39.0 TL3 | 1,000 | - | 10 | 15 | 10 | ||
4000xi | 800 | - | 8 | 12 | 8 | ||
4400 | 800 | - | 8 | 12 | 8 | ||
4500xi | 800 | - | 8 | 12 | 8 | ||
5000xi | 800 | - | 8 | 12 | 8 | ||
5300 | 800 | - | 8 | 12 | 8 | ||
5500 | 800 | - | 8 | 12 | 8 | ||
60.0 TL3 | 1000 | The possible input power is reduced at voltages lower than 480 V. The input current is limited to 36.0 A per input | 10 | 15 | 10 | ||
6400xi | 800 | - | 8 | 12 | 8 | ||
6600 | 800 | - | 8 | 12 | 8 | ||
6650xi | 800 | - | 8 | 12 | 8 | ||
7200xi | 800 | - | 8 | 12 | 8 | ||
7700 | 800 | - | 8 | 12 | 8 | ||
7900 | 800 | - | 8 | 12 | 8 | ||
8000xi | 800 | - | 8 | 12 | 8 | ||
8000xi Thinfilm High Voltage | 800 | - | 8 | 12 | 8 | ||
8000xi Thinfilm LV | 600 | - | 6 | 9 | 6 | ||
8600 | 800 | - | 8 | 12 | 8 | ||
9600 | 800 | - | 8 | 12 | 8 | ||
Kostal Solar Electric GmbH | Piko | 10.1 | 950 | - | 9 | 14 | 9 |
3.6 | 950 | - | 9 | 14 | 9 | ||
4.2 | 950 | - | 9 | 14 | 9 | ||
5.5 | 950 | - | 9 | 14 | 9 | ||
8.3 | 950 | - | 9 | 14 | 9 | ||
15 | 1000 | - | 10 | 15 | 10 | ||
L&T Electrical & Automation | G-Vertor RECon | 30H-900 | 1000 | - | 10 | 15 | 10 |
M+W Group GmbH | MW | 125 | 850 | - | 8 | 12 | 8 |
65 | 850 | - | 8 | 12 | 8 | ||
Mastervolt | SunMaster | CS 15 TL | 1,000 | - | 10 | 15 | 10 |
CS 20 TL | 1,000 | - | 10 | 15 | 10 | ||
Mitsubishi Electric Solar | XL | PV-PS40J | 380 | - | 3 | 5 | 3 |
PV-PN40G | 380 | - | 3 | 5 | 3 | ||
PV-PN55G | 380 | - | 3 | 5 | 3 | ||
PV-PS55J | 380 | - | 3 | 5 | 3 | ||
Oelmaier Technology GmbH | PAC | 2 | 750 | - | 7 | 11 | 7 |
3 | 750 | - | 7 | 11 | 7 | ||
4 | 750 | - | 7 | 11 | 7 | ||
5 | 750 | - | 7 | 11 | 7 | ||
7 | 750 | - | 7 | 11 | 7 | ||
Omron | KP | 100L | 850 | - | 8 | 12 | 8 |
KP40M | 400 | - | 4 | 6 | 4 | ||
KP40 K2-P | 385 | - | 3 | 5 | 3 | ||
KP55M | 400 | - | 4 | 6 | 4 | ||
KP55K2-P | 385 | - | 3 | 5 | 3 | ||
PAIRAN GmbH | PVI | 10000 | 1,000 | - | 10 | 15 | 10 |
8000 | 1,000 | - | 10 | 15 | 10 | ||
Power Electronics | HE HEC | 0200 H | 1000 | - | 10 | 15 | 10 |
0230 H | 1000 | - | 10 | 15 | 10 | ||
0250 H | 1000 | - | 10 | 15 | 10 | ||
0280 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0300 H | 1000 | - | 10 | 15 | 10 | ||
0340 H | 1000 | - | 10 | 15 | 10 | ||
0380 H | 1000 | - | 10 | 15 | 10 | ||
0400 H | 1000 | - | 10 | 15 | 10 | ||
0420 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0460 H | 1000 | - | 10 | 15 | 10 | ||
0500 H | 1000 | - | 10 | 15 | 10 | ||
0501 H | 1000 | - | 10 | 15 | 10 | ||
0560 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0570 H | 1000 | - | 10 | 15 | 10 | ||
0600 H | 1000 | - | 10 | 15 | 10 | ||
0630 H | 1000 | - | 10 | 15 | 10 | ||
0680 H | 1000 | - | 10 | 15 | 10 | ||
0700 H | 1000 | - | 10 | 15 | 10 | ||
0701 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0750 H | 1000 | - | 10 | 15 | 10 | ||
0800 H | 1000 | - | 10 | 15 | 10 | ||
0801 H | 1000 | - | 10 | 15 | 10 | ||
0830 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0880 H | 1000 | - | 10 | 15 | 10 | ||
0900 H | 1000 | - | 10 | 15 | 10 | ||
0910 H | 1000 | - | 10 | 15 | 10 | ||
0970 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
1001 H | 1000 | - | 10 | 15 | 10 | ||
1030 H | 1000 | - | 10 | 15 | 10 | ||
1100 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
1130 H | 1000 | - | 10 | 15 | 10 | ||
1140 H | 1000 | - | 10 | 15 | 10 | ||
1250 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
1251 H | 1000 | - | 10 | 15 | 10 | ||
1390 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0200 H | 1000 | - | 10 | 15 | 10 | ||
0230 H | 1000 | - | 10 | 15 | 10 | ||
0250 H | 1000 | - | 10 | 15 | 10 | ||
0280 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0300 H | 1000 | - | 10 | 15 | 10 | ||
0340 H | 1000 | - | 10 | 15 | 10 | ||
0380 H | 1000 | - | 10 | 15 | 10 | ||
0400 H | 1000 | - | 10 | 15 | 10 | ||
0420 H | 1000 | - | 10 | 15 | 10 | ||
0460 H | 1000 | - | 10 | 15 | 10 | ||
0500 H | 1000 | - | 10 | 15 | 10 | ||
0501 H | 1000 | - | 10 | 15 | 10 | ||
0560 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0570 H | 1000 | - | 10 | 15 | 10 | ||
0600 H | 1000 | - | 10 | 15 | 10 | ||
0630 H | 1000 | - | 10 | 15 | 10 | ||
0680 H | 1000 | - | 10 | 15 | 10 | ||
0700 H | 1000 | - | 10 | 15 | 10 | ||
0701 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0750 H | 1000 | - | 10 | 15 | 10 | ||
0800 H | 1000 | - | 10 | 15 | 10 | ||
0801 H | 1000 | - | 10 | 15 | 10 | ||
0830 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
0880 H | 1000 | - | 10 | 15 | 10 | ||
0900 H | 1000 | - | 10 | 15 | 10 | ||
0910 H | 1000 | - | 10 | 15 | 10 | ||
0970 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
1000 H | 1000 | - | 10 | 15 | 10 | ||
1001 H | 1000 | - | 10 | 15 | 10 | ||
1030 H | 1000 | - | 10 | 15 | 10 | ||
1100 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
1130 H | 1000 | - | 10 | 15 | 10 | ||
1140 H | 1000 | - | 10 | 15 | 10 | ||
1250 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
1251 H | 1000 | - | 10 | 15 | 10 | ||
1390 H | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
Power One Italy SpA | Aurora Trio | 20.0-TL-OUTD | 1,000 | - | 10 | 15 | 10 |
27.6-TL-OUTD | 1,000 | - | 10 | 15 | 10 | ||
PVI-10.0-OUTD | 900 | - | 9 | 13 | 9 | ||
PVI-12.5-OUTD | 900 | - | 9 | 13 | 9 | ||
Aurora Uno | PVI-2000 | 600 | - | 6 | 9 | 6 | |
PVI-3.0-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-3.0-OUTD-S | 600 | - | 6 | 9 | 6 | ||
PVI-3.0-TL-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-3.6-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-3.6-OUTD-S | 600 | - | 6 | 9 | 6 | ||
PVI-3.6-TL-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-3600 | 600 | - | 6 | 9 | 6 | ||
PVI-4.2-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-4.2-OUTD-S | 600 | - | 6 | 9 | 6 | ||
PVI-4.2-TL-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-5000-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-5000-OUTD-S | 600 | - | 6 | 9 | 6 | ||
PVI-5000-TL-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-6000-OUTD | 600 | - | 6 | 9 | 6 | ||
PVI-6000-OUTD-S | 600 | - | 6 | 9 | 6 | ||
PVI-6000-TL-OUTD | 600 | - | 6 | 9 | 6 | ||
Aurora Ultra | 1500-TL-OUTD-US | 1000 | - | 10 | 15 | 10 | |
PowerCom Co. | Solar King | SLK-4000 | 500 | - | 5 | 7 | 5 |
SLK-5000 | 600 | - | 6 | 9 | 6 | ||
SLK-6000 | 600 | - | 6 | 9 | 6 | ||
RefuSol GmbH | Refu Sol | 004K | 880 | - | 8 | 13 | 8 |
005K | 880 | - | 8 | 13 | 8 | ||
006K | 880 | - | 8 | 13 | 8 | ||
008K | 1,000 | - | 10 | 15 | 10 | ||
010 K | 1,000 | - | 10 | 15 | 10 | ||
013K | 1,000 | - | 10 | 15 | 10 | ||
017K | 1,000 | - | 10 | 15 | 10 | ||
020 K | 1,000 | - | 10 | 15 | 10 | ||
11k | 900 | - | 9 | 13 | 9 | ||
12k | 900 | - | 9 | 13 | 9 | ||
15K | 900 | - | 9 | 13 | 9 | ||
16K | 1,000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
Saft Power Systems Iberica, SL | Protect PV | 10 | 800 | - | 8 | 12 | 8 |
Schüco International KG | SGI | 30 K | 800 | - | 8 | 12 | 8 |
33k | 800 | - | 8 | 12 | 8 | ||
SGI plus | 2000 | 800 | - | 8 | 12 | 8 | |
2500 | 800 | - | 8 | 12 | 8 | ||
3000 | 800 | - | 8 | 12 | 8 | ||
3500 | 800 | - | 8 | 12 | 8 | ||
4000 | 800 | - | 8 | 12 | 8 | ||
4500 | 800 | - | 8 | 12 | 8 | ||
5500 | 800 | - | 8 | 12 | 8 | ||
SIAC | SOLEIL BT | 6 | 600 | - | 6 | 9 | 6 |
SOLEIL DSP TL | 330 TL | 930 | with external transformer | 9 | 14 | 9 | |
Schneider Electric | Conext TL | PVSNVC 10000 | 1000 | - | 10 | 15 | 10 |
PVSNVC 15000 | 1000 | - | 10 | 15 | 10 | ||
PVSNVC 20000 | 1000 | - | 10 | 15 | 10 | ||
PVSNVC 8000 | 1000 | - | 10 | 15 | 10 | ||
Shindengen | PV | PVS005T200 | 500 | - | 5 | 7 | 5 |
PVS010S200 | 540 | - | 5 | 8 | 5 | ||
PVS101T100 | 540 | - | 5 | 8 | 5 | ||
PVS9R9T200 | 540 | - | 5 | 8 | 5 | ||
Siemens AG | SINVERT | 340 MS | 900 | Voc Max @1000 V Optional | 9 | 13 | 9 |
400 MS | 900 | Voc Max @1000 V Optional | 9 | 13 | 9 | ||
SINVERT PVM | 10 | 1,000 | - | 10 | 15 | 10 | |
13 | 1,000 | - | 10 | 15 | 10 | ||
17 | 1,000 | - | 10 | 15 | 10 | ||
20 | 1,000 | - | 10 | 15 | 10 | ||
Sitop | 1500 | 675 | - | 6 | 10 | 6 | |
2000 | 675 | - | 6 | 10 | 6 | ||
2300 | 675 | - | 6 | 10 | 6 | ||
3000 | 675 | - | 6 | 10 | 6 | ||
4000 | 675 | - | 6 | 10 | 6 | ||
4600 | 675 | - | 6 | 10 | 6 | ||
SMA Solar Technology AG | Sunny Boy | 1300TL | 600 | - | 6 | 9 | 6 |
1600TL | 600 | - | 6 | 9 | 6 | ||
2100TL | 600 | - | 6 | 9 | 6 | ||
3000TL | 550 | - | 5 | 8 | 6 | ||
3300TL | 750 | - | 7 | 11 | 7 | ||
3300TL HC | 750 | - | 7 | 11 | 7 | ||
3600TL | 750 | - | 6 | 10 | 7 | ||
4000TL | 550 | - | 5 | 8 | 5 | ||
4200TL HC | 750 | - | 7 | 11 | 7 | ||
5000TL | 550 | - | 5 | 8 | 5 | ||
5000TL HC | 750 | - | 7 | 11 | 7 | ||
Sunny Mini Central | 10000TL | 700 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 10 | 7 | |
11000TL | 700 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 10 | 7 | ||
6000TL | 700 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 10 | 7 | ||
7000TL | 700 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 10 | 7 | ||
8000TL | 700 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 10 | 7 | ||
8000TL/V | 700 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 10 | 7 | ||
9000TL | 700 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 10 | 7 | ||
Sunny Tripower | 10000TL | 1,000 | - | 10 | 15 | 10 | |
12000TL | 1,000 | - | 10 | 15 | 10 | ||
12000TL-US | 1,000 | - | 10 | 15 | 10 | ||
15000TL | 1,000 | - | 10 | 15 | 10 | ||
15000TL-US | 1,000 | - | 10 | 15 | 10 | ||
17000TL | 1,000 | - | 10 | 15 | 10 | ||
5000TL | 1000 | - | 10 | 15 | 10 | ||
7000TL | 1000 | - | 10 | 15 | 10 | ||
8000TL | 1,000 | - | 10 | 15 | 10 | ||
9000TL | 1000 | - | 10 | 15 | 10 | ||
15000TLEE | 1,000 | Specification say Vmpp Min is 580 V but SMA stated that the inverter can track to 570 V.SMA has set minimum Rise to 250 K | 10 | 15 | 10 | ||
20000TLEE | 1,000 | Specification say Vmpp Min is 580 V but SMA stated that the inverter can track to 570 V. | 10 | 15 | 10 | ||
20000TL-US | 1000 | - | 10 | 15 | 10 | ||
24000TL-US | 1000 | - | 10 | 15 | 10 | ||
25000TL | 1000 | - | 10 | 15 | 10 | ||
FLX Pro | FLX Pro 17 | 1000 | - | 10 | 15 | 10 | |
Socomec | SUNSYS pro | SunSys 18K | 1,000 | - | 10 | 15 | 10 |
SunSys 24K | 1,000 | - | 10 | 15 | 10 | ||
Solar Edge | SE | 10 K | 950 | The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 9 | 14 | 9 |
12k | 950 | The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 9 | 14 | 9 | ||
3300 | 550 | The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 5 | 8 | 5 | ||
4000 | 550 | The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 5 | 8 | 5 | ||
5000 | 550 | The Solar Edge Power Box PB350 -TFI MPP - Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 5 | 8 | 5 | ||
6000 | 550 | The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 5 | 8 | 5 | ||
8k | 950 | The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 9 | 14 | 9 | ||
12,5k | 950 | The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. | 9 | 14 | 9 | ||
SOLUTRONIC GmbH | SOLPLUS | 100 | 850 | - | 8 | 12 | 8 |
120 | 850 | - | 8 | 12 | 8 | ||
25 | 850 | - | 8 | 12 | 8 | ||
300 | 850 | - | 8 | 12 | 8 | ||
35 | 850 | - | 8 | 12 | 8 | ||
50 | 850 | - | 8 | 12 | 8 | ||
55 | 850 | - | 8 | 12 | 8 | ||
Sputnik Engineering GmbH | SolarMax C | 2000C | 600 | - | 6 | 9 | 6 |
3000C | 600 | - | 6 | 9 | 6 | ||
4000C | 900 | - | 9 | 13 | 9 | ||
4200C | 600 | - | 6 | 9 | 6 | ||
6000C | 600 | - | 6 | 9 | 6 | ||
SolarMax MT | 8 MT2 | 900 | - | 9 | 13 | 9 | |
10 MT | 900 | - | 9 | 13 | 9 | ||
10 MT2 | 900 | - | 9 | 13 | 9 | ||
13 MT | 900 | - | 9 | 13 | 9 | ||
13 MT2 | 900 | - | 9 | 13 | 9 | ||
13 MT3 | 900 | - | 9 | 13 | 9 | ||
15 MT | 900 | - | 9 | 13 | 9 | ||
15 MT2 | 900 | - | 9 | 13 | 9 | ||
15 MT3 | 900 | - | 9 | 13 | 9 | ||
Solar Max P | 4600P | 600 | - | 6 | 9 | 6 | |
SolarMax S | 2000S | 600 | - | 6 | 9 | 6 | |
20S | 900 | - | 9 | 13 | 9 | ||
3000S | 600 | - | 6 | 9 | 6 | ||
35S | 900 | - | 9 | 13 | 9 | ||
4200S | 600 | - | 6 | 9 | 6 | ||
6000S | 600 | - | 6 | 9 | 6 | ||
Steca Elektronik GmbH | StecaGrid | 10000 3ph | 845 | - | 8 | 12 | 8 |
2000+ | 450 | - | 4 | 6 | 4 | ||
3000 | 800 | - | 8 | 12 | 8 | ||
3600 | 800 | - | 8 | 12 | 8 | ||
8000 3ph | 845 | - | 8 | 12 | 8 | ||
9000 3ph | 830 | - | 8 | 12 | 8 | ||
Sungrow Power Supply Co., Ltd. | SG | 10 KTL | 1,000 | - | 10 | 15 | 10 |
1.5KTL | 450 | - | 4 | 6 | 4 | ||
12KTL | 1,000 | - | 10 | 15 | 10 | ||
15KTL | 1,000 | - | 10 | 15 | 10 | ||
20 KTL | 1000 | - | 10 | 15 | 10 | ||
40 KTL | 1000 | - | 10 | 15 | 10 | ||
50 KTL | 1000 | - | 10 | 15 | 10 | ||
56KTL | 1000 | - | 10 | 15 | 10 | ||
56KU | 1000 | - | 10 | 15 | 10 | ||
60 KTL | 1000 | Transformer: Yes - modified MV transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manual re-connections could be needed during the lifetime of the system. | 9 | 14 | 9 | ||
60 KU | 1000 | - | 10 | 15 | 10 | ||
30 | 1000 | - | 10 | 15 | 10 | ||
30TKL-M | 1000 | - | 10 | 15 | 10 | ||
36KU | 1000 | - | 10 | 15 | 10 | ||
2K5TL-31 | 500 | - | 5 | 7 | 5 | ||
2K5TL-S | 600 | - | 6 | 9 | 6 | ||
3KTL-31 | 500 | - | 5 | 7 | 5 | ||
3KTL-EC | 1000 | - | 10 | 15 | 10 | ||
3KTL-S | 600 | - | 6 | 9 | 6 | ||
3K5TL-S | 600 | - | 6 | 9 | 6 | ||
4KTL-31 | 500 | - | 5 | 7 | 5 | ||
4KTL-EC | 1000 | - | 10 | 15 | 10 | ||
4K6TL-D | 600 | - | 6 | 9 | 6 | ||
4K6TL-S | 600 | - | 6 | 9 | 6 | ||
500MX | 1000 | - | 10 | 15 | 10 | ||
5KTL | 550 | - | 5 | 8 | 5 | ||
5KTL-D | 600 | - | 6 | 9 | 6 | ||
5KTL-EC | 1000 | - | 10 | 15 | 10 | ||
6KTL-EC | 1000 | - | 10 | 15 | 10 | ||
8KTL-EC | 1000 | - | 10 | 15 | 10 | ||
10 KTL-EC | 1000 | - | 10 | 15 | 10 | ||
12KTL-EC | 1000 | - | 10 | 15 | 10 | ||
Sunways AG | AT | 2700 | 680 | - | 6 | 10 | 6 |
3600 | 680 | - | 6 | 10 | 6 | ||
4500 | 680 | - | 6 | 10 | 6 | ||
5000 | 680 | - | 6 | 10 | 6 | ||
NT | 10000 | 900 | - | 9 | 13 | 9 | |
11000 | 900 | - | 9 | 13 | 9 | ||
12000 | 900 | - | 9 | 13 | 9 | ||
2500 | 900 | - | 9 | 13 | 9 | ||
2600 | 850 | - | 8 | 12 | 8 | ||
3700 | 900 | - | 9 | 13 | 9 | ||
4000 | 850 | - | 8 | 12 | 8 | ||
4200 | 900 | - | 9 | 13 | 9 | ||
5000 | 850 | - | 8 | 12 | 8 | ||
6000 | 850 | - | 8 | 12 | 8 | ||
8000 | 850 | - | 8 | 12 | 8 | ||
PT | 30 K | 1,000 | - | 10 | 15 | 10 | |
33k | 1,000 | - | 10 | 15 | 10 | ||
Tabuchi | Zebra | EPC-A-S55P | 450 | - | 4 | 6 | 4 |
EPC-A-S55P-H | 450 | - | 4 | 6 | 4 | ||
EPC-C-T250P-S | 750 | - | 7 | 11 | 7 | ||
EPC-B-S99P | 450 | - | 4 | 6 | 4 | ||
EPC-B-S99P-SB | 570 | - | 5 | 8 | 5 | ||
EPC-B-S99P-J | 450 | - | 4 | 6 | 4 | ||
TBEA Xi’an Electric Technology Co., LTD. | GC | 500 KTL | 1000 | - | 10 | 15 | 10 |
630 KTL | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
1000 KTL | 1000 | - | 10 | 15 | 10 | ||
TMEIC Corporation | Solar Ware | PVL-T0100UR-208/400 | 600 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 6 | 9 | 6 |
PVL-L0500E | 1000 | - | 10 | 15 | 10 | ||
PVL-L0630E | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
PVL-L1677GR | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
PVL-L0750E | 1000 | Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V | 10 | 15 | 10 | ||
Vacon | 8000 Solar 10 – 100 kW | NXV12503A2T | 900 | - | 9 | 13 | 9 |
Voltwerk electronics GmbH | VS | 11 | 1,000 | - | 10 | 15 | 10 |
15 | 1,000 | - | 10 | 15 | 10 | ||
3 | 940 | - | 9 | 14 | 9 | ||
4 | 940 | - | 9 | 14 | 9 | ||
5 | 940 | - | 9 | 14 | 9 | ||
8 | 1,000 | - | 10 | 15 | 10 | ||
Grupo WEG - Unidade Automação | SIW700 | T045 | 800 | - | 8 | 12 | 8 |
T055 | 800 | - | 8 | 12 | 8 | ||
T062 | 800 | - | 8 | 12 | 8 | ||
T068 | 800 | - | 8 | 12 | 8 | ||
T148 | 800 | - | 8 | 12 | 8 | ||
T165 | 800 | - | 8 | 12 | 8 | ||
T188 | 800 | - | 8 | 12 | 8 | ||
T215 | 800 | - | 8 | 12 | 8 | ||
T225 | 800 | - | 8 | 12 | 8 | ||
T250 | 800 | - | 8 | 12 | 8 | ||
T450 | 800 | - | 8 | 12 | 8 | ||
T675 | 800 | - | 8 | 12 | 8 | ||
T900 | 800 | - | 8 | 12 | 8 | ||
T1125 | 800 | - | 8 | 12 | 8 | ||
Zigor CORPORACIÓN S.A. | Sunzet | 100 TL | 800 | - | 8 | 12 | 8 |
30 TL | 800 | - | 8 | 12 | 8 | ||
50 TL | 800 | - | 8 | 12 | 8 |
Note: Cat® PVT 110 and PVT 110 ARC 2 and 3 modules have no exposed conductive surfaces and don not require equipment grounding as long as a clip length of
Note: Calculation for maximum number of modules in series is based on