This Special Instruction provides information regarding the compatible inverters without Galvanic Isolation for Cat® PVT 110 and PVT 110 ARC Photovoltaic modules.

Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.

Safety Section

Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.

A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.

Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.

Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Ensure that any tool, procedure, work method, or operating technique you use that is not recommended by Caterpillar is safe.

Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.

------ WARNING! ------

Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.


------ WARNING! ------

Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage.


------ WARNING! ------

When removing a major component or attachment, ensure that it is properly blocked or secured before removing mounting hardware. An assembly that is disconnected without proper blocking may shift or fall, resulting in serious injury or death of personnel or machine damage.


------ WARNING! ------

Personal injury or death can result from improper maintenance procedures. To avoid injury or death, follow the procedures exactly as stated below.


------ WARNING! ------

Personal injury can result from improper handling of chemicals.

Make sure you use all the necessary protective equipment required to do the job.

Make sure that you read and understand all directions and hazards described on the labels and material safety data sheet of any chemical that is used.

Observe all safety precautions recommended by the chemical manufacturer for handling, storage, and disposal of chemicals.


------ WARNING! ------

Climbing equipment may be required to access this service point. Refer to the Operation and Maintenance Manual, "Mounting and Dismounting" topic for safety information.


------ WARNING! ------

Before servicing/performing maintenance on the machine, electrical power must be physically disconnected; battery plugs must be disconnected from the batteries, or the trailing cable must be unplugged, and warning tags and padlocks shall be applied by a certified electrician. Certified electricians shall perform or direct any electrical work, including any energized testing, repair work in controllers, motors, or other approved compartments, and shall insure that all compartments are properly closed and inspected prior to re-energization. All applicable lock out and tag out procedures must be followed.


------ WARNING! ------

Do not operate the machine if any guards or covers are missing or inadequately secured. Personnel could be seriously injured or machine damage may occur.


------ WARNING! ------

Observe the safe working load limits of all lifting and blocking devices and keep a safe distance from suspended/blocked loads. Personnel may be seriously injured or killed by falling loads.


List of Compatible Inverters without Galvanic Isolation

Table 1
Manufacturer  Series  Type  VOC Max  External Remarks  FS2  FS3  FS4 
ABB  PVS 300-TL  3300W-2  900  13 
4000W-2 900 13 
4600W-2 900 13 
6000W-2 900 13 
8000W-2 900 13 
Advanced Energy  3TL  3TL 40  1000  10  15  10 
AEG Power Solutions  Protect PV  .250  1,000  10  15  10 
.500 1,000 10  15  10 
10 1,000 10  15  10 
12,5 1,000 10  15  10 
15 1,000 10  15  10 
2000 450
2800 500
4600 750 11 
8 1,000 10  15  10 
630 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
800 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
Aros  Sirio  K533 High Voltage-MT  880  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  13 
Bonfiglioli  RPS TL  0950  1000  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1780 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
Conergy AG  IPG S  3S  940  14 
4S 940 14 
5S 940 14 
IPG T 11 T  1,000  10  15  10 
15 T 1,000  10  15  10 
8 T 1,000  10  15  10 
Danfoss Solar Inverters A/S  TripleLynx  10 K  1,000  10  15  10 
12.5k 1,000 10  15  10 
15K 1,000 10  15  10 
8k 1,000 10  15  10 
Delta Energy Systems  Solivia  15 TL  1,000  10  15  10 
  20 TL 1,000  10  15  10 
  RPI  RPI-M20 A  1000  10  15  10 
  RPI402-1D 450 
Diehl Ako Stiftung & Co. KG  Platinum  11000 TL3  1,000  10  15  10 
13000 TL 880 13 
16000 TL 880 13 
19000 TL 880 13 
22000 TL 880 13 
4300 TL 880 13 
4800 TL 880 13 
5300 TL 880 13 
6300 TL 880 13 
7200 TL 880 13 
Eaton Corporation  Power Xpert Solar  1500 kW  1000  10  15  10 
1670 kW 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
Efacec Renewables  EFACEC  PV500  1000  10  15  10 
Effekta Regeltechnik GmbH  ES  3300  500 
4200 500
5000 500
Emerson  SPV  1060  1,000  10  15  10 
1200 1,000 10  15  10 
1410 1,000 10  15  10 
145 1,000 10  15  10 
1500 1,000 10  15  10 
1590 1,000 10  15  10 
175 1,000 10  15  10 
1800 1,000 10  15  10 
2100 1,000 10  15  10 
2400 1,000 10  15  10 
248 1,000 10  15  10 
2700 1,000 10  15  10 
300 1,000 10  15  10 
350 1,000 10  15  10 
600 1,000 10  15  10 
700 1,000 10  15  10 
880 1,000 10  15  10 
900 1,000 10  15  10 
Fronius International GmbH  IG TL  3.0  850  12 
3.6 850 12 
4.0 850 12 
5.0 850 12 
GE Solar  PSC  800 MV-L-QC  1300  10  15  10 
GEFRAN S.p.A  Radius Industrial  APV250 K-TL  1000  10  15  10 
APV270 K-TL 1000 10  15  10 
APV330 K-TL 1000 10  15  10 
APV660 K-TL 1000 10  15  10 
Growatt New Energy  Growatt  3600MTL-US  600 
4200MTL-US 600
5000MTL-US 600
Hitachi Hi-Rel Power Electronics Pvt. Ltd.  Solar PCS  250 kW  1000  10  15  10 
500 kW 1000 10  15  10 
630 kW 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
Huawei Technologies Co. LTD.  SUN2000  8KTL  1000  10  15  10 
10 KTL 1000 10  15  10 
12KTL 1000 10  15  10 
15KTL 1000 10  15  10 
17KTL 1000 10  15  10 
20 KTL 1000 10  15  10 
23KTL 1000 10  15  10 
28KTL 1000 10  15  10 
IBC Solar AG  ServeMaster  10000TL  1,000  10  15  10 
12500TL 1,000 10  15  10 
15000TL 1,000 10  15  10 
8000TL 1,000 10  15  10 
Ingeteam GmbH  IngeconSun Lite  2.5 TL  550 
3 TL 550
3.3 TL 550
3.68 TL 550
3.8 TL 550
4.6 TL 550
5 TL 550
6 TL 550
IngeconSun Power Max 100TL  900  13 
125TL 900  13 
250TL 900  13 
315TL 900  13 
375TL 900  13 
470TL 900  13 
500TL 900  13 
625TL 900  13 
630 HE TL 900  13 
IngeconSun Smart 10 TL  550 
12.5 TL 550 
15 TL 550 
18 TL 550 
KACO Gerätetechnik GmbH  Powador  10.0 TL3  1,000  10  15  10 
12.0 TL3 1,000 10  15  10 
14.0 TL3 1,000 10  15  10 
25000xi 800 12 
25000xi Park 800 12 
2500xi 800 12 
30.0 TL3 1,000 10  15  10 
30000xi 800 12 
30000xi Park 800 12 
3200 800 12 
33.0 TL3 1,000 10  15  10 
33000xi 800 12 
33000xi Park 800 12 
3500xi 800 12 
36.0 TL3 1,000 10  15  10 
3600xi 800 12 
37.5 TL3 1,000 10  15  10 
39.0 TL3 1,000 10  15  10 
4000xi 800 12 
4400 800 12 
4500xi 800 12 
5000xi 800 12 
5300 800 12 
5500 800 12 
60.0 TL3 1000 The possible input power is reduced at voltages lower than 480 V. The input current is limited to 36.0 A per input  10  15  10 
6400xi 800 12 
6600 800 12 
6650xi 800 12 
7200xi 800 12 
7700 800 12 
7900 800 12 
8000xi 800 12 
8000xi Thinfilm High Voltage 800 12 
8000xi Thinfilm LV 600
8600 800 12 
9600 800 12 
Kostal Solar Electric GmbH  Piko  10.1  950  14 
3.6 950 14 
4.2 950 14 
5.5 950 14 
8.3 950 14 
15 1000 10  15  10 
L&T Electrical & Automation  G-Vertor RECon  30H-900  1000  10  15  10 
M+W Group GmbH  MW  125  850  12 
65 850 12 
Mastervolt  SunMaster  CS 15 TL  1,000  10  15  10 
CS 20 TL 1,000 10  15  10 
Mitsubishi Electric Solar  XL  PV-PS40J  380 
PV-PN40G 380
PV-PN55G 380
PV-PS55J 380
Oelmaier Technology GmbH  PAC  750  11 
3 750 11 
4 750 11 
5 750 11 
7 750 11 
Omron  KP  100L  850  12 
KP40M 400
KP40 K2-P 385
KP55M 400
KP55K2-P 385
PAIRAN GmbH  PVI  10000  1,000  10  15  10 
8000 1,000 10  15  10 
Power Electronics  HE HEC  0200 H  1000  10  15  10 
0230 H 1000 10  15  10 
0250 H 1000 10  15  10 
0280 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0300 H 1000 10  15  10 
0340 H 1000 10  15  10 
0380 H 1000 10  15  10 
0400 H 1000 10  15  10 
0420 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0460 H 1000 10  15  10 
0500 H 1000 10  15  10 
0501 H 1000 10  15  10 
0560 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0570 H 1000 10  15  10 
0600 H 1000 10  15  10 
0630 H 1000 10  15  10 
0680 H 1000 10  15  10 
0700 H 1000 10  15  10 
0701 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0750 H 1000 10  15  10 
0800 H 1000 10  15  10 
0801 H 1000 10  15  10 
0830 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0880 H 1000 10  15  10 
0900 H 1000 10  15  10 
0910 H 1000 10  15  10 
0970 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1001 H 1000 10  15  10 
1030 H 1000 10  15  10 
1100 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1130 H 1000 10  15  10 
1140 H 1000 10  15  10 
1250 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1251 H 1000 10  15  10 
1390 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0200 H 1000 10  15  10 
0230 H 1000 10  15  10 
0250 H 1000 10  15  10 
0280 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0300 H 1000 10  15  10 
0340 H 1000 10  15  10 
0380 H 1000 10  15  10 
0400 H 1000 10  15  10 
0420 H 1000 10  15  10 
0460 H 1000 10  15  10 
0500 H 1000 10  15  10 
0501 H 1000 10  15  10 
0560 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0570 H 1000 10  15  10 
0600 H 1000 10  15  10 
0630 H 1000 10  15  10 
0680 H 1000 10  15  10 
0700 H 1000 10  15  10 
0701 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0750 H 1000 10  15  10 
0800 H 1000 10  15  10 
0801 H 1000 10  15  10 
0830 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
0880 H 1000 10  15  10 
0900 H 1000 10  15  10 
0910 H 1000 10  15  10 
0970 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1000 H 1000 10  15  10 
1001 H 1000 10  15  10 
1030 H 1000 10  15  10 
1100 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1130 H 1000 10  15  10 
1140 H 1000 10  15  10 
1250 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1251 H 1000 10  15  10 
1390 H 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
Power One Italy SpA  Aurora Trio  20.0-TL-OUTD  1,000  10  15  10 
27.6-TL-OUTD 1,000 10  15  10 
PVI-10.0-OUTD 900 13 
PVI-12.5-OUTD 900 13 
Aurora Uno PVI-2000  600 
PVI-3.0-OUTD 600 
PVI-3.0-OUTD-S 600 
PVI-3.0-TL-OUTD 600 
PVI-3.6-OUTD 600 
PVI-3.6-OUTD-S 600 
PVI-3.6-TL-OUTD 600 
PVI-3600 600 
PVI-4.2-OUTD 600 
PVI-4.2-OUTD-S 600 
PVI-4.2-TL-OUTD 600 
PVI-5000-OUTD 600 
PVI-5000-OUTD-S 600 
PVI-5000-TL-OUTD 600 
PVI-6000-OUTD 600 
PVI-6000-OUTD-S 600 
PVI-6000-TL-OUTD 600 
Aurora Ultra 1500-TL-OUTD-US  1000  10  15  10 
PowerCom Co.  Solar King  SLK-4000  500 
SLK-5000 600
SLK-6000 600
RefuSol GmbH  Refu Sol  004K  880  13 
005K 880 13 
006K 880 13 
008K 1,000 10  15  10 
010 K 1,000 10  15  10 
013K 1,000 10  15  10 
017K 1,000 10  15  10 
020 K 1,000 10  15  10 
11k 900 13 
12k 900 13 
15K 900 13 
16K 1,000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
Saft Power Systems Iberica, SL  Protect PV  10  800  12 
Schüco International KG  SGI  30 K  800  12 
33k 800 12 
SGI plus 2000  800  12 
2500 800  12 
3000 800  12 
3500 800  12 
4000 800  12 
4500 800  12 
5500 800  12 
SIAC  SOLEIL BT  600 
SOLEIL DSP TL 330 TL  930  with external transformer  14 
Schneider Electric  Conext TL  PVSNVC 10000  1000  10  15  10 
PVSNVC 15000 1000 10  15  10 
PVSNVC 20000 1000 10  15  10 
PVSNVC 8000 1000 10  15  10 
Shindengen  PV  PVS005T200  500 
PVS010S200 540
PVS101T100 540
PVS9R9T200 540
Siemens AG  SINVERT  340 MS  900  Voc Max @1000 V Optional  13 
400 MS 900 Voc Max @1000 V Optional  13 
SINVERT PVM 10  1,000  10  15  10 
13 1,000  10  15  10 
17 1,000  10  15  10 
20 1,000  10  15  10 
Sitop 1500  675  10 
2000 675  10 
2300 675  10 
3000 675  10 
4000 675  10 
4600 675  10 
SMA Solar Technology AG  Sunny Boy  1300TL  600 
1600TL 600
2100TL 600
3000TL 550
3300TL 750 11 
3300TL HC 750 11 
3600TL 750 10 
4000TL 550
4200TL HC 750 11 
5000TL 550
5000TL HC 750 11 
Sunny Mini Central 10000TL  700  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10 
11000TL 700  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10 
6000TL 700  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10 
7000TL 700  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10 
8000TL 700  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10 
8000TL/V 700  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10 
9000TL 700  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10 
Sunny Tripower 10000TL  1,000  10  15  10 
12000TL 1,000  10  15  10 
12000TL-US 1,000  10  15  10 
15000TL 1,000  10  15  10 
15000TL-US 1,000  10  15  10 
17000TL 1,000  10  15  10 
5000TL 1000  10  15  10 
7000TL 1000  10  15  10 
8000TL 1,000  10  15  10 
9000TL 1000  10  15  10 
15000TLEE 1,000  Specification say Vmpp Min is 580 V but SMA stated that the inverter can track to 570 V.SMA has set minimum Rise to 250 K  10  15  10 
20000TLEE 1,000  Specification say Vmpp Min is 580 V but SMA stated that the inverter can track to 570 V.  10  15  10 
20000TL-US 1000  10  15  10 
24000TL-US 1000  10  15  10 
25000TL 1000  10  15  10 
FLX Pro FLX Pro 17  1000  10  15  10 
Socomec  SUNSYS pro  SunSys 18K  1,000  10  15  10 
SunSys 24K 1,000 10  15  10 
Solar Edge  SE  10 K  950  The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level.  14 
12k 950 The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level.  14 
3300 550 The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. 
4000 550 The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. 
5000 550 The Solar Edge Power Box PB350 -TFI MPP - Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. 
6000 550 The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level. 
8k 950 The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level.  14 
12,5k 950 The Solar Edge Power Box PB350 -TFI MPP -Tracker is mandatory for the usage of this inverter. The mentioned MPP Tracker is on module level.  14 
SOLUTRONIC GmbH  SOLPLUS  100  850  12 
120 850 12 
25 850 12 
300 850 12 
35 850 12 
50 850 12 
55 850 12 
Sputnik Engineering GmbH  SolarMax C  2000C  600 
3000C 600
4000C 900 13 
4200C 600
6000C 600
SolarMax MT 8 MT2  900  13 
10 MT 900  13 
10 MT2 900  13 
13 MT 900  13 
13 MT2 900  13 
13 MT3 900  13 
15 MT 900  13 
15 MT2 900  13 
15 MT3 900  13 
Solar Max P 4600P  600 
SolarMax S 2000S  600 
20S 900  13 
3000S 600 
35S 900  13 
4200S 600 
6000S 600 
Steca Elektronik GmbH  StecaGrid  10000 3ph  845  12 
2000+ 450
3000 800 12 
3600 800 12 
8000 3ph 845 12 
9000 3ph 830 12 
Sungrow Power Supply Co., Ltd.  SG  10 KTL  1,000  10  15  10 
1.5KTL 450
12KTL 1,000 10  15  10 
15KTL 1,000 10  15  10 
20 KTL 1000 10  15  10 
40 KTL 1000 10  15  10 
50 KTL 1000 10  15  10 
56KTL 1000 10  15  10 
56KU 1000 10  15  10 
60 KTL 1000 Transformer: Yes - modified MV transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manual re-connections could be needed during the lifetime of the system.  14 
60 KU 1000 10  15  10 
30 1000 10  15  10 
30TKL-M 1000 10  15  10 
36KU 1000 10  15  10 
2K5TL-31 500
2K5TL-S 600
3KTL-31 500
3KTL-EC 1000 10  15  10 
3KTL-S 600
3K5TL-S 600
4KTL-31 500
4KTL-EC 1000 10  15  10 
4K6TL-D 600
4K6TL-S 600
500MX 1000 10  15  10 
5KTL 550
5KTL-D 600
5KTL-EC 1000 10  15  10 
6KTL-EC 1000 10  15  10 
8KTL-EC 1000 10  15  10 
10 KTL-EC 1000 10  15  10 
12KTL-EC 1000 10  15  10 
Sunways AG  AT  2700  680  10 
3600 680 10 
4500 680 10 
5000 680 10 
NT 10000  900  13 
11000 900  13 
12000 900  13 
2500 900  13 
2600 850  12 
3700 900  13 
4000 850  12 
4200 900  13 
5000 850  12 
6000 850  12 
8000 850  12 
PT 30 K  1,000  10  15  10 
33k 1,000  10  15  10 
Tabuchi  Zebra  EPC-A-S55P  450 
EPC-A-S55P-H 450
EPC-C-T250P-S 750 11 
EPC-B-S99P 450
EPC-B-S99P-SB 570
EPC-B-S99P-J 450
TBEA Xi’an Electric Technology Co., LTD.  GC  500 KTL  1000  10  15  10 
630 KTL 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
1000 KTL 1000 10  15  10 
TMEIC Corporation  Solar Ware  PVL-T0100UR-208/400  600  Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V 
PVL-L0500E 1000 10  15  10 
PVL-L0630E 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
PVL-L1677GR 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
PVL-L0750E 1000 Transformer: Yes – modified MV / High Voltage transformer with multiple taps to adjust mpp window (min mpp 570 V  10  15  10 
Vacon  8000 Solar 10 – 100 kW  NXV12503A2T  900  13 
Voltwerk electronics GmbH  VS  11  1,000  10  15  10 
15 1,000 10  15  10 
3 940 14 
4 940 14 
5 940 14 
8 1,000 10  15  10 
Grupo WEG - Unidade Automação  SIW700  T045  800  12 
T055 800 12 
T062 800 12 
T068 800 12 
T148 800 12 
T165 800 12 
T188 800 12 
T215 800 12 
T225 800 12 
T250 800 12 
T450 800 12 
T675 800 12 
T900 800 12 
T1125 800 12 
Zigor CORPORACIÓN S.A.  Sunzet  100 TL  800  12 
30 TL 800 12 
50 TL 800 12 

Note: Cat® PVT 110 and PVT 110 ARC 2 and 3 modules have no exposed conductive surfaces and don not require equipment grounding as long as a clip length of 100 mm (4 inch) for a standard four clip mounting is not is not exceeded.

Note: Calculation for maximum number of modules in series is based on −10° C (14° F) cell temperature and 700W/m2 irradiation.

Caterpillar Information System:

Compatible Inverters for Certain Cat® PVT 110 and PVT 110 ARC With Galvanic Isolation Photovoltaic Modules {1471, 4822} Compatible Inverters for Certain Cat® PVT 110 and PVT 110 ARC With Galvanic Isolation Photovoltaic Modules {1471, 4822}
Shading Field Guide for Certain Cat® Photovoltaic Modules {1471} Shading Field Guide for Certain Cat® Photovoltaic Modules {1471}
Module Characterization Response of Certain Cat® PVT 110 and PVT 110 ARC Photovoltaic Modules to Partial Shading {1471} Module Characterization Response of Certain Cat® PVT 110 and PVT 110 ARC Photovoltaic Modules to Partial Shading {1471}
System Operating Voltage for Cat® PVT110, PVT115, PVT117, and PVT120 Photovoltaic Module {1471} System Operating Voltage for Cat® PVT110, PVT115, PVT117, and PVT120 Photovoltaic Module {1471}
Cleaning Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {0115} Cleaning Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {0115}
140 Motor Grader Systems Piston Pump (All Wheel Drive)
C175 Petroleum Engine Sensor Supply - Test
C175 Petroleum Engine Oil Pressure Is Low
C175 Petroleum Engine Oil Filter Differential Pressure Problem - If Equipped with the Self-Cleaning Oil Filter
307.5, 308, 308.5, 309, and 310 Mini Hydraulic Excavator Machine Systems Camera - Remove and Install
A New Process Is Available to Request Service Animations for Certain Service Information Procedures {1000, 7000} A New Process Is Available to Request Service Animations for Certain Service Information Procedures {1000, 7000}
307.5, 308, 308.5, 309, and 310 Mini Hydraulic Excavator Machine Systems Pedal Control and Mounting - Remove and Installl
C175 Petroleum Engine Crankcase Pressure Is High
C175 Petroleum Engine Sensor Calibration Required - Test
Approved Retaining Clips for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471, 7553} Approved Retaining Clips for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471, 7553}
307.5, 308, 308.5, 309, and 310 Mini Hydraulic Excavator Machine System General Information (Stick System)
Application Notes for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471} Application Notes for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471}
C175 Petroleum Engine Turbocharger Turbine Speed Is High
Reverse Current Overload for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471} Reverse Current Overload for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471}
Module Breakage Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471} Module Breakage Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471}
C175 Petroleum Engine Intake Manifold Air Temperature Is High
C175 Petroleum Engine Sensor Signal (Analog, Passive) - Test
140 Motor Grader Systems Pump Control (All Wheel Drive)
307.5, 308, 308.5, 309, and 310 Mini Hydraulic Excavator Machine System Electronic Control (Stick System)