Compatible Inverters for Certain Cat® PVT 110 and PVT 110 ARC With Galvanic Isolation Photovoltaic Modules {1471, 4822} Caterpillar


Compatible Inverters for Certain Cat® PVT 110 and PVT 110 ARC With Galvanic Isolation Photovoltaic Modules {1471, 4822}

Usage:

PVT110 TF2
Photovoltaic
PVT110 (S/N: TF21-UP)
PVT115 (S/N: TF51-UP)
PVT117 (S/N: TF71-UP)
PVT120 (S/N: GH81-UP; TF81-UP)

Introduction

This Special Instruction provides information regarding the compatible inverters for Cat® PVT 110 and PVT 110 ARC with Galvanic Isolation.

Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.

Safety Section

Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.

A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.

Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.

Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Ensure that any tool, procedure, work method, or operating technique you use that is not recommended by Caterpillar is safe.

Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.

------ WARNING! ------

Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility.


------ WARNING! ------

Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage.


------ WARNING! ------

When removing a major component or attachment, ensure that it is properly blocked or secured before removing mounting hardware. An assembly that is disconnected without proper blocking may shift or fall, resulting in serious injury or death of personnel or machine damage.


------ WARNING! ------

Personal injury or death can result from improper maintenance procedures. To avoid injury or death, follow the procedures exactly as stated below.


------ WARNING! ------

Personal injury can result from improper handling of chemicals.

Make sure you use all the necessary protective equipment required to do the job.

Make sure that you read and understand all directions and hazards described on the labels and material safety data sheet of any chemical that is used.

Observe all safety precautions recommended by the chemical manufacturer for handling, storage, and disposal of chemicals.


------ WARNING! ------

Climbing equipment may be required to access this service point. Refer to the Operation and Maintenance Manual, "Mounting and Dismounting" topic for safety information.


------ WARNING! ------

Before servicing/performing maintenance on the machine, electrical power must be physically disconnected; battery plugs must be disconnected from the batteries, or the trailing cable must be unplugged, and warning tags and padlocks shall be applied by a certified electrician. Certified electricians shall perform or direct any electrical work, including any energized testing, repair work in controllers, motors, or other approved compartments, and shall insure that all compartments are properly closed and inspected prior to re-energization. All applicable lock out and tag out procedures must be followed.


------ WARNING! ------

Do not operate the machine if any guards or covers are missing or inadequately secured. Personnel could be seriously injured or machine damage may occur.


------ WARNING! ------

Observe the safe working load limits of all lifting and blocking devices and keep a safe distance from suspended/blocked loads. Personnel may be seriously injured or killed by falling loads.


List of Compatible Inverters

This document provides a list of inverters that are compatible and approved for the usage with the CAT PVT 110 and PVT 110 ARC Modules. This list does not provide performance evaluations or comparisons between inverters and does not recommend a specific inverter manufacturer. Absence from the list does not indicate that there is an incompatibility with an inverter, only that CAT has not completed the verification of the inverter.

CAT warrants its PVT 110 and 110 ARC modules according to the CAT Module Warranty Terms & Conditions (CAT PD-5-102, “Module Warranty Terms & Conditions”) provided modules are installed, operated and serviced as described in the CAT User Guide (CAT PD-5-200, “User Guide”) and in the System Design and Application document (CAT PD-2-303, “SDA”).

CAT requires all system designs to be submitted for review and approval via the SDA process; therefore, for warranty purposes, every system with CAT modules must be covered by an SDA. Project Developers and\or Customers should request this document from CAT and obtain approval prior to equipment procurement and installation.

Approval of the following listed inverters is based upon and in accordance with the inverter data sheet effective at the time of evaluation. Thus, changes in inverter specification after CAT approval may nullify the confirmation of compatibility. CAT reserves the right to change the approval requirements for the inverter as well as a possible revocation of the inverter approval list.

Table 1
Manufacturer  Series  Type  VOC Max  External Remarks  FS2  FS3  FS4 
ABB  P VS800  57-0100 KW-A  1000  10  15  10 
57-0250 KW-A 1000  10 15  10 
57-0500 KW-A 1000  10 15  10 
57-0315 KW-B 1000  10 15  10 
57-0630 KW-B 1100  11 16  11 
57-0875 KW-B 1100  11 16  11 
57-1000 KW-C 1100  11 17  11 
Advanced Energy  PV Powered  P VP 35 KW  600 
P VP 50 KW 600  6
Solaron AE 500NX  750  7 11 
AE 500NX-1k V 1000  approved for this Bi-Polar installation using BIAS control which has to limit the Voltage to +/-70 V to ground, Multiple Taps recommended for adjustment of MPP window.  10  15  10 
333NX 600  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manual re-connections could be needed during the lifetime of the system. 
AMK Antriebs- und Steuerungstechnik GmbH & Co. KG  AMKASYN  S 100-WT  1,000  10  15  10 
S 88-WT 1,000  10 15  10 
Answer Drives S.r.l  Solar gate  P V7L  800  12 
P V7M 800 with external transformer  12 
P V8L 900 13 
P V8M 900 with external transformer  13 
Aros  Sirio  125k  800  12 
125K-H V 880  transformer : Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manual re-connections could be needed during the lifetime of the system.  13 
16k 800  12 
20k 800  12 
30k 800  12 
K100 800  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 415 V). Several manual re-connections could be needed during the lifetime of the system.  12 
K100 H V 880  13 
K12 800  12 
K250 800  12 
K40 800  12 
K40 H V 880  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 415 V). Several manual re-connections could be needed during the lifetime of the system.  13 
K80 800  12 
K80 H V 880  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 415 V). Several manual re-connections could be needed during the lifetime of the system.  13 
Beijing Corona Science & Technology Co., Ltd.  KNGI900  500HEA  900  with external transformer  13 
Bonfiglioli Vectron  RPS 450  120  900  13 
170 900  13 
30 900  13 
60 900  13 
RPS TL 0280  900  with external transformer  13 
0310 900  with external transformer  13 
0340 900  with external transformer  13 
0380 900  with external transformer  13 
0420 (1000 V option) 1,000  with external transformer  10  15  10 
0470 900  with external transformer  13 
0510 900  with external transformer  13 
0570 900  wit external transformer  13 
0620 (1000 V option) 1,000  with external transformer  10  15  10 
0680 900  with external transformer  13 
0760 900  with external transformer  13 
0830 (1000 V option) 1,000  with external transformer  10  15  10 
0850 900  wit external transformer  13 
0940 900  wit external transformer  13 
1040 (1000 V option) 1,000  with external transformer  10  15  10 
1110 900  with external transformer  13 
1220 (1000 V option) 1,000 with external transformer  10  15  10 
1460 (1000 V option) 1,000 with external transformer  10  15  10 
0450 1,000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
0685 1,000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
0900 1,000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
1130 1,000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
1360 1,000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
1580 1,000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
Conergy AG  Conergy Central  30  800  12 
40 800 12 
50 800 12 
IPG C 200 C  1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 517 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
300 C 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 517 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
IPG K 110K  1,000  Conergy Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
280K 1,000  Conergy Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
300K 1,000  Conergy Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
40K 1,000  Conergy Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
60K 1,000  Conergy Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
80K 1,000  Conergy Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
Sun Profi SP1300  450 
SP2500 450 
SP3100 450 
SP3400 600 
CON VERTEAM SAS  Con VerSOL  1000AI  900  13 
1275LI 1,200 10  14  10 
1500LI 1,200 10  15  10 
1700LI 1,200 10  14  10 
425 LI 1,200 10  14  10 
500 AI 900 13 
670AI 900 13 
850LI 1,200 10  14  10 
PSC 430M V - L - QC  1,000  10  15  10 
500M V - L - QC 1,000  10  15  10 
Danfoss Solar inverters A/S  ULX  1800  550 
3000 550
3600 550
5400 550
DLX 2.0 UL  600 
2.9 UL 600 
3.8 UL 600 
4.4 UL 600 
Delta Energy Systems  CI  100  900  13 
SI 2000  540 
2500 540 
3300 540 
5000 540 
Soli Via 2.5  540 
3.0 540 
3.3 540 
5.0 540 
CM 100 900  13 
CM 77 900  13 
CM 88 900  13 
CS 44 900  13 
CS 55 900  13 
CS 66 900  13 
Diehl Ako Stiftung & Co. KG  100CS  900  900  13 
2100S 480  480 
2800S 780  780  11 
3100S 780  780  11 
3800S 780  780  11 
4300S 780  780  11 
4600S 780  780  11 
4601S 580  580  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 259 V). Several manual re-connections could be needed during the lifetime of the system. 
Eaton Corporation  Eaton Power Xpert Solar  1500 KW  1000  10  15  10 
1670 KW 1000 10  15  10 
Elettronica Santerno  Sunway M Plus  M Plus 1300 E  600 
M Plus 2600 E 600
M Plus 3600 600
M Plus 3600 E 600
M Plus 4300 600
M Plus 4300 E 600
M Plus 5300 600
M Plus 6000 600
M Plus 6400 600
M Plus 7500 600
M Plus 7800 600
Sunway TG 1000 V TE TG 750 1000 V TE  1,000  with external transformer  10  15  10 
Sunway TG 600 V TG 110 600 V  740  11 
TG 135 600 V 740  11 
TG 14 600 V 740  11 
TG 19 600 V 740  11 
TG 26 600 V 740  11 
TG 30 600 V 740  11 
TG 37 600 V 740  11 
TG 42 600 740  11 
TG 61 600 740  11 
TG 90 600 V 740  11 
Sunway TG 600 V TE TG 180 600 V TE  740  11 
TG 230 600 V TE 740  with external transformer  11 
TG 280 600 V TE 740  with external transformer  11 
TG 290 600 V TE 740  with external transformer  11 
TG 365 600 V TE 740  with external transformer  11 
TG 455 600 V TE 740  with external transformer  11 
TG 550 600 V TE 740  with external transformer  11 
Sunway TG 800 V TG 120 800 V  880  13 
TG 145 800 V 880  13 
TG 35 800 V 880  13 
TG 49 800 V 880  13 
TG 57 800 V 880  13 
TG 82 800 V 880  13 
Sunway TG 800 V TE TG 175 800 V TE  880  with external transformer  13 
TG 240 800 V TE 880  with external transformer  13 
TG 300 800 V TE 880  with external transformer  13 
TG 310 800 V TE 880  with external transformer  13 
TG 385 800 V TE 880  with external transformer  13 
TG 485 800 V TE 880  with external transformer  13 
TG 610 800 V TE 880  with external transformer  13 
TG 730 800 V TE 880  with external transformer  13 
Eltek Valere  THEIA  100 KW  900  13 
2.0 HE-t 600
2.9 HE-t 600
20 KW 900 13 
3.8 HE-t 600
30 KW 900 13 
4.4 HE-t 600
50 KW 900 13 
THEIA TL 150 KW  900  with external M V transformer  13 
200 KW 900  with external M V transformer  13 
250 KW 900  with external M V transformer  13 
350 KW 900  with external M V transformer  13 
500 KW 900  with external M V transformer  13 
500 KW with EI V Kit 950  with external M V transformer  14 
El Vi_Uni Versal  QCC  100k  800  12 
30k 800 12 
55k 800 12 
Emerson  SSL  0100  1,000  with external transformer  10  15  10 
0250 1,000 with external transformer  10  15  10 
0500 1,000 with external transformer  10  15  10 
1000 1,000 with external transformer  10  15  10 
FRIEM S.p.A.  RECon  30H-150  900  with external transformer  13 
30H-150-T 900 13 
30H-300 900 with external transformer  13 
30H-300-T 900 13 
30H-450 900 with external transformer  13 
30H-450-T 900 13 
30H-600 900 with external transformer  13 
30H-600-T 900 13 
30L-100 700 with external transformer  10 
30L-100-T 700 10 
30L-200 700 with external transformer  10 
30L-200-T 700 10 
30L-300 700 with external transformer  10 
30L-300-T 700 10 
30L-400 700 with external transformer  10 
30L-400-T 700 10 
60H-1200 900 with external transformer  13 
60H-1200-T 900 13 
60H-300 900 with external transformer  13 
60H-300-T 900 13 
60H-600 900 with external transformer  13 
60H-600-T 900 13 
60H-900 900 with external transformer  13 
60H-900-T 900 13 
60L-200 700 with external transformer  10 
60L-200-T 700 10 
60L-400 700 with external transformer  10 
60L-400-T 700 10 
60L-600 700 with external transformer  10 
60L-600-T 700 10 
60L-800 700 with external transformer  10 
60L-800-T 700 10 
Fronius International GmbH  CL  36.0  600 
48.0 600
60.0 600
IG 15  500 
20 500 
2000 500 
2500-L V 500 
30 500 
300 530 
3000 500 
390 530 
40 500 
400 530 
4000 500 
4500L V 500 
500 530 
5100 500 
60 H V 530 
IG Plus 100  600 
100 V 600 
11.4-1 Uni 600 
120 600 
120 V 600 
150 600 
150 V 600 
30 V 600 
35 600 
35 V 600 
50 600 
50 V 600 
70 600 
70 V 600 
Gamesa Corporación Tecnológica S.A.  Central inverter  100 KW  900  13 
500 KW PLUS 1,000 with external transformer  10  15  10 
GE Energy  ProSolar II  PSC-4.000-L-QC  1500  Modified M V/H V transformer with multiple taps to adjust mpp window (min mpp 544 V for 15 FS3 modules in series; min mpp 782 for 15 FS4 modules in series). Several manual re-connections could be needed during the lifetime of the system.  10  15  15 
GEFRAN S.p.A.  Radius Industrial  AP V 100k-T-E  1,000  10  15  10 
Green Power  Power P V  10  900  13 
100 900 13 
20 900 13 
250 1,000 10  15  10 
30 900 13 
5 600
50 900 13 
500 1,000 10  15  10 
Helios Systems  HS  100  900  13 
HSC 1000C  900  with external transformer  13 
HSI 500  900  with external transformer  13 
Hitachi Hi-Rel Power Electronics P Vt. Ltd.  1000 KW  1000 KW Solar PCS  1000  10  15  10 
IBC Solar AG  Serve Master  1650 H V  600 
1650 M V 450
3300 H V 600
3300 M V 450
4600 H V 600
4600 M V 450
IDS Trade AG  SOLO  500  1,000  with external transformer  10  15  10 
Ingeteam GmbH  IngeconSun  500HE  900  with external transformer  13 
500HE (1000 V option) 1,000 with external transformer  10  15  10 
IngeconSun Lite 2,5  550 
3,3 550 
5 550 
IngeconSun Power 100  900  13 
50 900  13 
60 900  13 
70 900  13 
80 900  13 
90 900  13 
IngeconSun Smart 10  900  13 
12,5 900  13 
15 900  13 
20 900  13 
25 900  13 
30 900  13 
JEMA  IF  100  900  13 
20 900 13 
25 900 13 
30 900 13 
50 900 13 
60 900 13 
80 900 13 
KACO Gerätetechnik GmbH  Blue planet 02xi Series  1502xi  550 
2502xi 550
3502xi 600
5002xi 600
Blue planet XP100-U H2  600 
H4 600 
Powador 14.0 TR3  600 
1501xi 500 
16.0 TR3 600 
18.0 TR3 600 
2002 600 
3002 600 
3501xi 500 
4202 600 
4501xi 500 
5002 600 
6002 600 
TS20-H V 800  12 
TS21-H V 800  12 
Powador XP 100-H V  1,000  10  15  10 
200-H V 1,000  10  15  10 
200-H V TL 1,000  with external transformer  10  15  10 
250-H V 1,000  10  15  10 
250-H V TL 1,000  with external transformer  10  15  10 
350-H V TL 1,000  with external transformer  10  15  10 
XP100N-H2 600 
XP100N-OD-H2 600 
XP499-H V-TL 1000  10  15  10 
XP500-H V-TL 1000  10  15  10 
XP499-OD-TL 1000  10  15  10 
XP500-OD-TL 1000  10  15  10 
Kostal Solar Electric GmbH  Piko  100  1,000  10  15  10 
Leonics  Apollo GTP-500  GTP-501  600 
GTP-502 600
GTP-503 600
GTP-504 600
GTP-505 600
GTP-506 600
GTP-507 600
GTP-508 780 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system.  11 
GTP-509 780 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system.  11 
GTP-510 780 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system.  11 
GTP-511 780 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system.  11 
GTP-512 780 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system.  11 
LTi REEnergy GmbH  P V Master-Station  P VMB 45-0270  900  approved when used with an external transformer  13 
P VMB 45-0540 900 approved when used with an external transformer  13 
P VMB 45-0810 900 approved when used with an external transformer  13 
P VMB 45-1080 900 approved when used with an external transformer  13 
P VMC 45-0270 900 Approved when used with an external transformer  13 
P VMC 45-0540 900 approved when used with an external transformer  13 
P VMC 45-0810 900 approved when used with an external transformer  13 
P VMC 45-1080 900 approved when used with an external transformer  13 
P VMI 45-0270 900 approved when used with an external transformer  13 
P VMI 45-0540 900 approved when used with an external transformer  13 
P VMI 45-0810 900 approved when used with an external transformer  13 
P VMI 45-1080 900 approved when used with an external transformer  13 
P Vmaster II P VM 450-075 TT  900  13 
P VM 450-090 TT 900  13 
P VM 450-100 TT 900  13 
P VM 450-110 TT 900  13 
P VM 450-132 EN/EM 900  with external transformer  13 
P VM 450-175 EN/EM 900  with external transformer  13 
P VM 450-230 EN/EM 900  with external transformer  13 
P VM 450-270 EN/EM 900  with external transformer  13 
P VM2 45-132EM 900  approved when used with external transformer  13 
P VM2 45-175EM 900  approved when used with an external transformer  13 
P VM2 45-230EM 900  approved when used with an external transformer  13 
P VM2 45-270EM 900  with external transformer  13 
P VM2 50-200EM 900  transformer :Yes – modified M V transformer with taps to adjust the mpp window up to an minimal Voltage of 450 V is mandatory. (new mpp window: 450-850 VDC)  13 
P VM2 50-305EM 900  transformer :Yes – modified M V transformer with taps to adjust the mpp window up to an minimal Voltage of 450 V is mandatory. (new mpp window: 450-850 VDC)  13 
Master Volt  SunMaster  QS 1200  450 
QS 2000 450
QS 3200 450
QS 3200 Max-I 450
QS 3500 Max-I 325
QS 6400 450
QS 6400 Max-I 450
XL 10  550 
15 600 
XS 2000  450 
3200 600 
4300 550 
6500 600 
Motech Industries Inc.  P VMate  2800E  600 
2900U 600
3800E 600
3840U 600
4000E 600
4900U 600
5000E 600
5300U 600
Nedap  Power Router  PR30S  600 
PR37S 600
PR50S 600
Nextronex Energy Systems  RAY-MAX  150  1,000  with external transformer  10  15  10 
150 (600 V) 600 To ensure a proper operation of this inverter in an 600 V DC system, it is mandatory to change the taps on the coupling transformer to 208 V. This action will allow to export power up to a minimum Voltage of 318 V DC. 
NIDEC  Solar Gate 5000  P V9-M380NP  1100  15 
Nissin  SPM  SPM100-CS1B  750  11 
SPM250-CS1B 750 11 
SPM500-CS1B 750 11 
Oelmaier Technology GmbH  HS  100  900  13 
PAIRAN GmbH  pesos  P VI 2300 T  500 
Power Electronics  freesun HES  0250OH  900  with external M V-transformer  13 
0300OH 900 with external M V-transformer  13 
0400OH 900 with external M V-transformer  13 
0500OH 900 with external M V-transformer  13 
0600OH 900 with external M V-transformer  13 
0700OH 900 with external M V-transformer  13 
0800OH 900 with external M V-transformer  13 
0900OH 900 with external M V-transformer  13 
1000OH 900 with external M V-transformer  13 
freesun L VT 0020  900  13 
0025 900  13 
0030 900  13 
0035 900  13 
0040 900  13 
0050 900  13 
0060 900  13 
0080 900  13 
0100 900  13 
HEC FS 1001CU-PU  1000  10  15  10 
FS 1250CU-PU 1000  With tap adjustment to 510 V  10  15  10 
Power One Italy SpA  Aurora Lite  P VI-250.0-TL-CN  1,000  with external transformer  10  15  10 
P VI-500.0TL-CN 1,000 with external transformer  10  15  10 
Aurora Plus P VI-110.0  1,000  10  15  10 
P VI-110.0-TL 1,000  with external transformer  10  15  10 
P VI-165.0 1,000  10  15  10 
P VI-165.0-TL 1,000  with external transformer  10  15  10 
P VI-220.0 1,000  10  15  10 
P VI-220.0-TL 1,000  with external transformer  10  15  10 
P VI-275.0 1,000  10  15  10 
P VI-275.0-TL 1,000  with external transformer  10  15  10 
P VI-330.0 1,000  10  15  10 
P VI-330.0-TL 1,000  with external transformer  10  15  10 
P VI-55.0 1,000  10  15  10 
P VI-Central-100 900  13 
P VI-Central-100-TL 900  with external transformer  13 
P VI-Central-150 900  13 
P VI-Central-150-TL 900  with external transformer  13 
P VI-Central-200 900  13 
P VI-Central-200-TL 900  with external transformer  13 
P VI-Central-250 900  13 
P VI-Central-250-TL 900  with external transformer  13 
P VI-Central-300 900  13 
P VI-Central-300-TL 900  with external transformer  13 
P VI-Central-50 900  13 
Aurora Trio P VI-10.0-I-OUTD  520 
P VI-12.0-I-OUTD 520 
Aurora Ultra 1050.0-TL-OUTD-690  1,100  with external transformer  10  15  10 
1400.0-TL-OUTD-690 1,100  with external transformer  10  15  10 
700.0-TL-OUTD-690 1,100  with external transformer  10  15  10 
Aurora Uno P VI-3.8-I-OUTD  520 
P VI-4.6-I-OUTD 520 
RefuSol GmbH  Refu Sol  100k  850  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 414 V). Several manual re-connections could be needed during the lifetime of the system.  12 
160K 850 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 414 V). Several manual re-connections could be needed during the lifetime of the system.  12 
500K 950 14 
630K 950 14 
RIELLO UPS  Helios Power  HP 100  800  12 
HP 25 800 12 
HP 33 800 12 
HP 40 800 12 
HP 64 800 12 
HP 80 800 12 
Satcon  PowerGate Plus  100 KW  900  13 
135 KW 600 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 310 V). Several manual re-connections could be needed during the lifetime of the system. 
1MW 900 13 
250 KW 900 13 
30 KW 600
375 KW 600 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 310 V). Several manual re-connections could be needed during the lifetime of the system. 
50 KW 600
500 KW 900 13 
75 KW 600
Solstice 500 KW-CE  900  13 
500 KW-UL/CSA 600 
Schneider Electric  Conext  Core XC 540  1,000  10  15  10 
Core XC 630 1,000 10  15  10 
Core XC 680 1,000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 517 V). Several manual re-connections could be needed during the lifetime of the system.  10  15  10 
Conext CL CL25000E  1000  10  15  10 
Schüco International KG  IPE  100CT  900  13 
30CT 900 13 
60CT 900 13 
SGI plus 1500 T  500 
3500 T 500 
4500 T 500 
Shindengen  P V  P VS100T200-ID-DN-H1  650 
SIAC  SOLEIL DSP  10  780  11 
100 780 11 
125 780 11 
15 780 11 
20 780 11 
200 780 11 
25 780 11 
250 780 11 
30 780 11 
40 780 11 
400 780 11 
50 780 11 
500 780 11 
60 780 11 
80 780 11 
Siemens AG  SIN VERT  1000 MS TL  1,000  with external transformer  10  15  10 
1000MS 900 13 
1300 MS 900 13 
1400MS 900 13 
1500 MS TL 1,000 with external transformer  10  15  10 
1700 MS 900 13 
2000 MS TL 1,000 with external transformer  10  15  10 
350M 900 13 
420M 900 13 
500 M TL 1,000 with external transformer  10  15  10 
700MS 900 13 
850MS 900 13 
SIN VERT P VS 1000  1,000  wit external transformer  10  15  10 
1200 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
1500 1,000  with external transformer  10  15  10 
1800 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
2000 1,000  with external transformer  10  15  10 
500 1,000  with external transformer  10  15  10 
600 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
2400 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
SMA Solar Technology AG  Sunny Boy  1200  400 
1700 400
2000 HF 700 10 
2500 600
2500 HF 700 10 
3000 600
3000 HF 700 10 
3300 500
3800 500
5000US 600
6000US 600
7000US 600
700US 250
Sunny Central 100  900  13 
1000M V 1,000  10  15  10 
1250 M V 1,000  10  15  10 
200 880  13 
250 880  13 
250HE 880  13 
350 880  13 
400HE 1,000  10  15  10 
400M V 1,000  10  15  10 
500CP 1,000  with external transformer  10  15  10 
500HE 1,000  10  15  10 
500HE-20 1,000  with external transformer  10  15  10 
500M V 1,000  10  15  10 
630CP 1,000  with external transformer  10  15  10 
630HE 1,000  10  15  10 
630HE-20 1,000  with external transformer  10  15  10 
630M V 1,000  10  15  10 
720 CP 1,000  with external transformer  10  15  10 
800M V 1,000  10  15  10 
800CP 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
750CP-US 1000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
760 CP 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 530 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
800HE-20 1,000  transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
900CP 1,000  transformer :Yes – modified M V/H V transformer with multiple taps to adjust mpp window (min mpp 545 V). Several manually re-connections could be needed during the lifetime of the system approved only for FS Series 3    15   
Sunny Mini Central 4600A  600 
5000A 600 
6000A 600 
7000H V 800  12 
Socomec  SUNSYS  P03  900  with external transformer  13 
R01 900 13 
R02 900 13 
Solectria Renewables, LLC  P VI  10 KW  475 
13 KW 475
15 KW 475
SOLUTRONIC GmbH  SOLEIL DSP  10  780  11 
100 780 11 
125 780 11 
15 780 11 
20 780 11 
200 780 11 
25 780 11 
250 780 11 
30 780 11 
40 780 11 
400 780 11 
50 780 11 
500 780 11 
60 780 11 
80 780 11 
Sputnik Engineering GmbH  SolarMax C  100C  900  13 
20C 900 13 
25C 900 13 
300C 900 13 
30C 900 13 
330C-S V 900 with external transformer  13 
35C 900 13 
50C 900 13 
80C 900 13 
SolarMax TS 100TS  900  13 
300TS 900  13 
330TS-S V 900  with external transformer  13 
50TS 900  13 
80TS 900  13 
Sungrow Power Supply Co., Ltd.  SG  100K3  900  13 
SG 100KC-Outdoor 600
SG 100Ku-Outdoor 600
250K3 900 13 
500K3 900 13 
500KTL 900 with external transformer  13 
SG 500L V 600
SG 500MX-M 1000 10  15  10 
50K3 900 13 
630KTL 1,000 with external transformer  10  15  10 
SG 630MX 1000 10  15  10 
SG 630MX-E 1000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
SG 750MX 1000 10  15  10 
SG 800MX 1000 transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manually re-connections could be needed during the lifetime of the system.  10  15  10 
SG1000TS 1000 10  15  10 
SG1000TS-M V 1000 10  15  10 
SunTechnics  STW  2000  800  12 
2800 800 12 
3800 800 12 
5000 800 12 
Vensys  Vencon  1500  1120  10  15  10 
Vencon 2000  1120  10  15  10 
Vacon  NXP  CH 64  1,000  with external transformer Sinusstrom Bea Ver for max. system Voltage of 1000 V is mandatory  10  15  10 
NX V 0600-4  900  13 
Voltwerk electronics GmbH  VC  WL 110  1,000  Voltwerk Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
WL 280 1,000 Voltwerk Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
WL 300 1,000 Voltwerk Smart Connect for max. system Voltage of 1000 V is mandatory  10  15  10 
Xantrex Technologies Inc.  GT  100-480  600 
100E 650
2.8 600
250-480 600
3.8 600
5.0 600
500E 940 14 
500-M VX 600 with external transformer 
540E 1,000 with external transformer  10  15  10 
630E 1,000 with external transformer 1000 V Version as well as an adjustment of the power tracking window range to an min. DC Voltage of 515 V is mandatory.  10  15  10 
XC 540  1,000  with external transformer  10  15  10 
630 1,000  with external transformer  10  15  10 
Zigor CORPORACIÓN S.A.  Sunzet  100 T  800  12 
30 T 800 12 
50 T 800 12 

Caterpillar Information System:

Shading Field Guide for Certain Cat® Photovoltaic Modules {1471} Shading Field Guide for Certain Cat® Photovoltaic Modules {1471}
Module Characterization Response of Certain Cat® PVT 110 and PVT 110 ARC Photovoltaic Modules to Partial Shading {1471} Module Characterization Response of Certain Cat® PVT 110 and PVT 110 ARC Photovoltaic Modules to Partial Shading {1471}
System Operating Voltage for Cat® PVT110, PVT115, PVT117, and PVT120 Photovoltaic Module {1471} System Operating Voltage for Cat® PVT110, PVT115, PVT117, and PVT120 Photovoltaic Module {1471}
Cleaning Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {0115} Cleaning Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {0115}
140 Motor Grader Systems Piston Pump (All Wheel Drive)
C175 Petroleum Engine Sensor Supply - Test
C175 Petroleum Engine Oil Pressure Is Low
C175 Petroleum Engine Oil Filter Differential Pressure Problem - If Equipped with the Self-Cleaning Oil Filter
307.5, 308, 308.5, 309, and 310 Mini Hydraulic Excavator Machine Systems Camera - Remove and Install
A New Process Is Available to Request Service Animations for Certain Service Information Procedures {1000, 7000} A New Process Is Available to Request Service Animations for Certain Service Information Procedures {1000, 7000}
307.5, 308, 308.5, 309, and 310 Mini Hydraulic Excavator Machine Systems Pedal Control and Mounting - Remove and Installl
797F and 797F XQ Off-Highway Trucks Machine Systems Electronic Control Module (VIMS Main Module) - Remove and Install
Compatible Inverters without Galvanic Isolation for Certain Cat® PVT 110 and PVT 110 ARC Photovoltaic Modules {1471} Compatible Inverters without Galvanic Isolation for Certain Cat® PVT 110 and PVT 110 ARC Photovoltaic Modules {1471}
C175 Petroleum Engine Crankcase Pressure Is High
C175 Petroleum Engine Sensor Calibration Required - Test
Approved Retaining Clips for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471, 7553} Approved Retaining Clips for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471, 7553}
307.5, 308, 308.5, 309, and 310 Mini Hydraulic Excavator Machine System General Information (Stick System)
Application Notes for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471} Application Notes for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471}
C175 Petroleum Engine Turbocharger Turbine Speed Is High
Reverse Current Overload for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471} Reverse Current Overload for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471}
Module Breakage Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471} Module Breakage Guidelines for Cat® PVT110, PVT115, PVT117, and PVT120 PhotoVoltaic Module {1471}
C175 Petroleum Engine Intake Manifold Air Temperature Is High
C175 Petroleum Engine Sensor Signal (Analog, Passive) - Test
140 Motor Grader Systems Pump Control (All Wheel Drive)