Introduction
This Special Instruction provides information regarding the compatible inverters for Cat® PVT 110 and PVT 110 ARC with Galvanic Isolation.
Do not perform any procedure in this Special Instruction until you have read the information and you understand the information.
Safety Section
Work safely. Most accidents that involve product operation, maintenance, and repair are caused by failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing potentially hazardous situations before an accident occurs.
A person must be alert to potential hazards. This person should also have the necessary training, skills, and tools to perform these functions properly.
Safety precautions and warnings are provided in this instruction and on the product. If these hazard warnings are not heeded, bodily injury or death could occur to you or to other persons. Caterpillar cannot anticipate every possible circumstance that might involve a potential hazard.
Therefore, the warnings in this publication and the warnings that are on the product are not all inclusive. Ensure that any tool, procedure, work method, or operating technique you use that is not recommended by Caterpillar is safe.
Ensure that the product will not be damaged or the product will not be made unsafe by the operation, lubrication, maintenance, or repair procedures used.
Do not operate or work on this product unless you have read and understood the instruction and warnings in the relevant Operation and Maintenance Manuals and relevant service literature. Failure to follow the instructions or heed the warnings could result in injury or death. Proper care is your responsibility. |
Failure to follow all safety guidelines prescribed in this document and by governing authorities and regulatory agencies may result in severe injury or death of personnel or machine damage. |
When removing a major component or attachment, ensure that it is properly blocked or secured before removing mounting hardware. An assembly that is disconnected without proper blocking may shift or fall, resulting in serious injury or death of personnel or machine damage. |
Personal injury or death can result from improper maintenance procedures. To avoid injury or death, follow the procedures exactly as stated below. |
Personal injury can result from improper handling of chemicals. Make sure you use all the necessary protective equipment required to do the job. Make sure that you read and understand all directions and hazards described on the labels and material safety data sheet of any chemical that is used. Observe all safety precautions recommended by the chemical manufacturer for handling, storage, and disposal of chemicals. |
Climbing equipment may be required to access this service point. Refer to the Operation and Maintenance Manual, "Mounting and Dismounting" topic for safety information. |
Before servicing/performing maintenance on the machine, electrical power must be physically disconnected; battery plugs must be disconnected from the batteries, or the trailing cable must be unplugged, and warning tags and padlocks shall be applied by a certified electrician. Certified electricians shall perform or direct any electrical work, including any energized testing, repair work in controllers, motors, or other approved compartments, and shall insure that all compartments are properly closed and inspected prior to re-energization. All applicable lock out and tag out procedures must be followed. |
Do not operate the machine if any guards or covers are missing or inadequately secured. Personnel could be seriously injured or machine damage may occur. |
Observe the safe working load limits of all lifting and blocking devices and keep a safe distance from suspended/blocked loads. Personnel may be seriously injured or killed by falling loads. |
List of Compatible Inverters
This document provides a list of inverters that are compatible and approved for the usage with the CAT PVT 110 and PVT 110 ARC Modules. This list does not provide performance evaluations or comparisons between inverters and does not recommend a specific inverter manufacturer. Absence from the list does not indicate that there is an incompatibility with an inverter, only that CAT has not completed the verification of the inverter.
CAT warrants its PVT 110 and 110 ARC modules according to the CAT Module Warranty Terms & Conditions (CAT PD-5-102, “Module Warranty Terms & Conditions”) provided modules are installed, operated and serviced as described in the CAT User Guide (CAT PD-5-200, “User Guide”) and in the System Design and Application document (CAT PD-2-303, “SDA”).
CAT requires all system designs to be submitted for review and approval via the SDA process; therefore, for warranty purposes, every system with CAT modules must be covered by an SDA. Project Developers and\or Customers should request this document from CAT and obtain approval prior to equipment procurement and installation.
Approval of the following listed inverters is based upon and in accordance with the inverter data sheet effective at the time of evaluation. Thus, changes in inverter specification after CAT approval may nullify the confirmation of compatibility. CAT reserves the right to change the approval requirements for the inverter as well as a possible revocation of the inverter approval list.
Manufacturer | Series | Type | VOC Max | External Remarks | FS2 | FS3 | FS4 |
---|---|---|---|---|---|---|---|
ABB | P VS800 | 57-0100 KW-A | 1000 | - | 10 | 15 | 10 |
57-0250 KW-A | 1000 | 10 | 15 | 10 | |||
57-0500 KW-A | 1000 | 10 | 15 | 10 | |||
57-0315 KW-B | 1000 | 10 | 15 | 10 | |||
57-0630 KW-B | 1100 | 11 | 16 | 11 | |||
57-0875 KW-B | 1100 | 11 | 16 | 11 | |||
57-1000 KW-C | 1100 | 11 | 17 | 11 | |||
Advanced Energy | PV Powered | P VP 35 KW | 600 | - | 6 | 9 | 6 |
P VP 50 KW | 600 | 6 | 9 | 6 | |||
Solaron | AE 500NX | 750 | 7 | 11 | 7 | ||
AE 500NX-1k V | 1000 | approved for this Bi-Polar installation using BIAS control which has to limit the Voltage to +/-70 V to ground, Multiple Taps recommended for adjustment of MPP window. | 10 | 15 | 10 | ||
333NX | 600 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manual re-connections could be needed during the lifetime of the system. | 6 | 9 | 6 | ||
AMK Antriebs- und Steuerungstechnik GmbH & Co. KG | AMKASYN | S 100-WT | 1,000 | - | 10 | 15 | 10 |
S 88-WT | 1,000 | 10 | 15 | 10 | |||
Answer Drives S.r.l | Solar gate | P V7L | 800 | - | 8 | 12 | 8 |
P V7M | 800 | with external transformer | 8 | 12 | 8 | ||
P V8L | 900 | - | 9 | 13 | 9 | ||
P V8M | 900 | with external transformer | 9 | 13 | 9 | ||
Aros | Sirio | 125k | 800 | - | 8 | 12 | 8 |
125K-H V | 880 | transformer : Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manual re-connections could be needed during the lifetime of the system. | 8 | 13 | 8 | ||
16k | 800 | - | 8 | 12 | 8 | ||
20k | 800 | - | 8 | 12 | 8 | ||
30k | 800 | - | 8 | 12 | 8 | ||
K100 | 800 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 415 V). Several manual re-connections could be needed during the lifetime of the system. | 8 | 12 | 8 | ||
K100 H V | 880 | - | 8 | 13 | 8 | ||
K12 | 800 | - | 8 | 12 | 8 | ||
K250 | 800 | - | 8 | 12 | 8 | ||
K40 | 800 | - | 8 | 12 | 8 | ||
K40 H V | 880 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 415 V). Several manual re-connections could be needed during the lifetime of the system. | 8 | 13 | 8 | ||
K80 | 800 | - | 8 | 12 | 8 | ||
K80 H V | 880 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 415 V). Several manual re-connections could be needed during the lifetime of the system. | 8 | 13 | 8 | ||
Beijing Corona Science & Technology Co., Ltd. | KNGI900 | 500HEA | 900 | with external transformer | 9 | 13 | 9 |
Bonfiglioli Vectron | RPS 450 | 120 | 900 | - | 9 | 13 | 9 |
170 | 900 | - | 9 | 13 | 9 | ||
30 | 900 | - | 9 | 13 | 9 | ||
60 | 900 | - | 9 | 13 | 9 | ||
RPS TL | 0280 | 900 | with external transformer | 9 | 13 | 9 | |
0310 | 900 | with external transformer | 9 | 13 | 9 | ||
0340 | 900 | with external transformer | 9 | 13 | 9 | ||
0380 | 900 | with external transformer | 9 | 13 | 9 | ||
0420 (1000 V option) | 1,000 | with external transformer | 10 | 15 | 10 | ||
0470 | 900 | with external transformer | 9 | 13 | 9 | ||
0510 | 900 | with external transformer | 9 | 13 | 9 | ||
0570 | 900 | wit external transformer | 9 | 13 | 9 | ||
0620 (1000 V option) | 1,000 | with external transformer | 10 | 15 | 10 | ||
0680 | 900 | with external transformer | 9 | 13 | 9 | ||
0760 | 900 | with external transformer | 9 | 13 | 9 | ||
0830 (1000 V option) | 1,000 | with external transformer | 10 | 15 | 10 | ||
0850 | 900 | wit external transformer | 9 | 13 | 9 | ||
0940 | 900 | wit external transformer | 9 | 13 | 9 | ||
1040 (1000 V option) | 1,000 | with external transformer | 10 | 15 | 10 | ||
1110 | 900 | with external transformer | 9 | 13 | 9 | ||
1220 (1000 V option) | 1,000 | with external transformer | 10 | 15 | 10 | ||
1460 (1000 V option) | 1,000 | with external transformer | 10 | 15 | 10 | ||
0450 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
0685 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
0900 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
1130 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
1360 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
1580 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 515 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
Conergy AG | Conergy Central | 30 | 800 | - | 8 | 12 | 8 |
40 | 800 | - | 8 | 12 | 8 | ||
50 | 800 | - | 8 | 12 | 8 | ||
IPG C | 200 C | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 517 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | |
300 C | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 517 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
IPG K | 110K | 1,000 | Conergy Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | |
280K | 1,000 | Conergy Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | ||
300K | 1,000 | Conergy Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | ||
40K | 1,000 | Conergy Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | ||
60K | 1,000 | Conergy Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | ||
80K | 1,000 | Conergy Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | ||
Sun Profi | SP1300 | 450 | - | 4 | 6 | 4 | |
SP2500 | 450 | - | 4 | 6 | 4 | ||
SP3100 | 450 | - | 4 | 6 | 4 | ||
SP3400 | 600 | - | 6 | 9 | 6 | ||
CON VERTEAM SAS | Con VerSOL | 1000AI | 900 | - | 9 | 13 | 9 |
1275LI | 1,200 | - | 10 | 14 | 10 | ||
1500LI | 1,200 | - | 10 | 15 | 10 | ||
1700LI | 1,200 | - | 10 | 14 | 10 | ||
425 LI | 1,200 | - | 10 | 14 | 10 | ||
500 AI | 900 | - | 9 | 13 | 9 | ||
670AI | 900 | - | 9 | 13 | 9 | ||
850LI | 1,200 | - | 10 | 14 | 10 | ||
PSC | 430M V - L - QC | 1,000 | - | 10 | 15 | 10 | |
500M V - L - QC | 1,000 | - | 10 | 15 | 10 | ||
Danfoss Solar inverters A/S | ULX | 1800 | 550 | - | 5 | 8 | 5 |
3000 | 550 | - | 5 | 8 | 5 | ||
3600 | 550 | - | 5 | 8 | 5 | ||
5400 | 550 | - | 5 | 8 | 5 | ||
DLX | 2.0 UL | 600 | - | 6 | 9 | 6 | |
2.9 UL | 600 | - | 6 | 9 | 6 | ||
3.8 UL | 600 | - | 6 | 9 | 6 | ||
4.4 UL | 600 | - | 6 | 9 | 6 | ||
Delta Energy Systems | CI | 100 | 900 | - | 9 | 13 | 9 |
SI | 2000 | 540 | - | 5 | 8 | 5 | |
2500 | 540 | - | 5 | 8 | 5 | ||
3300 | 540 | - | 5 | 8 | 5 | ||
5000 | 540 | - | 5 | 8 | 5 | ||
Soli Via | 2.5 | 540 | - | 5 | 8 | 5 | |
3.0 | 540 | - | 5 | 8 | 5 | ||
3.3 | 540 | - | 5 | 8 | 5 | ||
5.0 | 540 | - | 5 | 8 | 5 | ||
CM 100 | 900 | - | 9 | 13 | 9 | ||
CM 77 | 900 | - | 9 | 13 | 9 | ||
CM 88 | 900 | - | 9 | 13 | 9 | ||
CS 44 | 900 | - | 9 | 13 | 9 | ||
CS 55 | 900 | - | 9 | 13 | 9 | ||
CS 66 | 900 | - | 9 | 13 | 9 | ||
Diehl Ako Stiftung & Co. KG | 100CS | 900 | 900 | - | 9 | 13 | 9 |
2100S | 480 | 480 | - | 4 | 7 | 4 | |
2800S | 780 | 780 | - | 7 | 11 | 7 | |
3100S | 780 | 780 | - | 7 | 11 | 7 | |
3800S | 780 | 780 | - | 7 | 11 | 7 | |
4300S | 780 | 780 | - | 7 | 11 | 7 | |
4600S | 780 | 780 | - | 7 | 11 | 7 | |
4601S | 580 | 580 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 259 V). Several manual re-connections could be needed during the lifetime of the system. | 5 | 8 | 5 | |
Eaton Corporation | Eaton Power Xpert Solar | 1500 KW | 1000 | - | 10 | 15 | 10 |
1670 KW | 1000 | - | 10 | 15 | 10 | ||
Elettronica Santerno | Sunway M Plus | M Plus 1300 E | 600 | - | 6 | 9 | 5 |
M Plus 2600 E | 600 | - | 6 | 9 | 6 | ||
M Plus 3600 | 600 | - | 6 | 9 | 6 | ||
M Plus 3600 E | 600 | - | 6 | 9 | 6 | ||
M Plus 4300 | 600 | - | 6 | 9 | 6 | ||
M Plus 4300 E | 600 | - | 6 | 9 | 6 | ||
M Plus 5300 | 600 | - | 6 | 9 | 6 | ||
M Plus 6000 | 600 | - | 6 | 9 | 6 | ||
M Plus 6400 | 600 | - | 6 | 9 | 6 | ||
M Plus 7500 | 600 | - | 6 | 9 | 6 | ||
M Plus 7800 | 600 | - | 6 | 9 | 6 | ||
Sunway TG 1000 V TE | TG 750 1000 V TE | 1,000 | with external transformer | 10 | 15 | 10 | |
Sunway TG 600 V | TG 110 600 V | 740 | - | 7 | 11 | 7 | |
TG 135 600 V | 740 | - | 7 | 11 | 7 | ||
TG 14 600 V | 740 | - | 7 | 11 | 7 | ||
TG 19 600 V | 740 | - | 7 | 11 | 7 | ||
TG 26 600 V | 740 | - | 7 | 11 | 7 | ||
TG 30 600 V | 740 | - | 7 | 11 | 7 | ||
TG 37 600 V | 740 | - | 7 | 11 | 7 | ||
TG 42 600 | 740 | - | 7 | 11 | 7 | ||
TG 61 600 | 740 | - | 7 | 11 | 7 | ||
TG 90 600 V | 740 | - | 7 | 11 | 7 | ||
Sunway TG 600 V TE | TG 180 600 V TE | 740 | - | 7 | 11 | 7 | |
TG 230 600 V TE | 740 | with external transformer | 7 | 11 | 7 | ||
TG 280 600 V TE | 740 | with external transformer | 7 | 11 | 7 | ||
TG 290 600 V TE | 740 | with external transformer | 7 | 11 | 7 | ||
TG 365 600 V TE | 740 | with external transformer | 7 | 11 | 7 | ||
TG 455 600 V TE | 740 | with external transformer | 7 | 11 | 7 | ||
TG 550 600 V TE | 740 | with external transformer | 7 | 11 | 7 | ||
Sunway TG 800 V | TG 120 800 V | 880 | - | 8 | 13 | 8 | |
TG 145 800 V | 880 | - | 8 | 13 | 8 | ||
TG 35 800 V | 880 | - | 8 | 13 | 8 | ||
TG 49 800 V | 880 | - | 8 | 13 | 8 | ||
TG 57 800 V | 880 | - | 8 | 13 | 8 | ||
TG 82 800 V | 880 | - | 8 | 13 | 8 | ||
Sunway TG 800 V TE | TG 175 800 V TE | 880 | with external transformer | 8 | 13 | 8 | |
TG 240 800 V TE | 880 | with external transformer | 8 | 13 | 8 | ||
TG 300 800 V TE | 880 | with external transformer | 8 | 13 | 8 | ||
TG 310 800 V TE | 880 | with external transformer | 8 | 13 | 8 | ||
TG 385 800 V TE | 880 | with external transformer | 8 | 13 | 8 | ||
TG 485 800 V TE | 880 | with external transformer | 8 | 13 | 8 | ||
TG 610 800 V TE | 880 | with external transformer | 8 | 13 | 8 | ||
TG 730 800 V TE | 880 | with external transformer | 8 | 13 | 8 | ||
Eltek Valere | THEIA | 100 KW | 900 | - | 9 | 13 | 9 |
2.0 HE-t | 600 | - | 6 | 9 | 6 | ||
2.9 HE-t | 600 | - | 6 | 9 | 6 | ||
20 KW | 900 | - | 9 | 13 | 9 | ||
3.8 HE-t | 600 | - | 6 | 9 | 6 | ||
30 KW | 900 | - | 9 | 13 | 9 | ||
4.4 HE-t | 600 | - | 6 | 9 | 6 | ||
50 KW | 900 | - | 9 | 13 | 9 | ||
THEIA TL | 150 KW | 900 | with external M V transformer | 9 | 13 | 9 | |
200 KW | 900 | with external M V transformer | 9 | 13 | 9 | ||
250 KW | 900 | with external M V transformer | 9 | 13 | 9 | ||
350 KW | 900 | with external M V transformer | 9 | 13 | 9 | ||
500 KW | 900 | with external M V transformer | 9 | 13 | 9 | ||
500 KW with EI V Kit | 950 | with external M V transformer | 9 | 14 | 9 | ||
El Vi_Uni Versal | QCC | 100k | 800 | - | 8 | 12 | 8 |
30k | 800 | - | 8 | 12 | 8 | ||
55k | 800 | - | 8 | 12 | 8 | ||
Emerson | SSL | 0100 | 1,000 | with external transformer | 10 | 15 | 10 |
0250 | 1,000 | with external transformer | 10 | 15 | 10 | ||
0500 | 1,000 | with external transformer | 10 | 15 | 10 | ||
1000 | 1,000 | with external transformer | 10 | 15 | 10 | ||
FRIEM S.p.A. | RECon | 30H-150 | 900 | with external transformer | 9 | 13 | 9 |
30H-150-T | 900 | - | 9 | 13 | 9 | ||
30H-300 | 900 | with external transformer | 9 | 13 | 9 | ||
30H-300-T | 900 | - | 9 | 13 | 9 | ||
30H-450 | 900 | with external transformer | 9 | 13 | 9 | ||
30H-450-T | 900 | - | 9 | 13 | 9 | ||
30H-600 | 900 | with external transformer | 9 | 13 | 9 | ||
30H-600-T | 900 | - | 9 | 13 | 9 | ||
30L-100 | 700 | with external transformer | 7 | 10 | 7 | ||
30L-100-T | 700 | - | 7 | 10 | 7 | ||
30L-200 | 700 | with external transformer | 7 | 10 | 7 | ||
30L-200-T | 700 | - | 7 | 10 | 7 | ||
30L-300 | 700 | with external transformer | 7 | 10 | 7 | ||
30L-300-T | 700 | - | 7 | 10 | 7 | ||
30L-400 | 700 | with external transformer | 7 | 10 | 7 | ||
30L-400-T | 700 | - | 7 | 10 | 7 | ||
60H-1200 | 900 | with external transformer | 9 | 13 | 9 | ||
60H-1200-T | 900 | - | 9 | 13 | 9 | ||
60H-300 | 900 | with external transformer | 9 | 13 | 9 | ||
60H-300-T | 900 | - | 9 | 13 | 9 | ||
60H-600 | 900 | with external transformer | 9 | 13 | 9 | ||
60H-600-T | 900 | - | 9 | 13 | 9 | ||
60H-900 | 900 | with external transformer | 9 | 13 | 9 | ||
60H-900-T | 900 | - | 9 | 13 | 9 | ||
60L-200 | 700 | with external transformer | 7 | 10 | 7 | ||
60L-200-T | 700 | - | 7 | 10 | 7 | ||
60L-400 | 700 | with external transformer | 7 | 10 | 7 | ||
60L-400-T | 700 | - | 7 | 10 | 7 | ||
60L-600 | 700 | with external transformer | 7 | 10 | 7 | ||
60L-600-T | 700 | - | 7 | 10 | 7 | ||
60L-800 | 700 | with external transformer | 7 | 10 | 7 | ||
60L-800-T | 700 | - | 7 | 10 | 7 | ||
Fronius International GmbH | CL | 36.0 | 600 | - | 6 | 9 | 6 |
48.0 | 600 | - | 6 | 9 | 6 | ||
60.0 | 600 | - | 6 | 9 | 6 | ||
IG | 15 | 500 | - | 5 | 7 | 5 | |
20 | 500 | - | 5 | 7 | 5 | ||
2000 | 500 | - | 5 | 7 | 5 | ||
2500-L V | 500 | - | 5 | 7 | 5 | ||
30 | 500 | - | 5 | 7 | 5 | ||
300 | 530 | - | 5 | 7 | 5 | ||
3000 | 500 | - | 5 | 7 | 5 | ||
390 | 530 | - | 5 | 7 | 5 | ||
40 | 500 | - | 5 | 7 | 5 | ||
400 | 530 | - | 5 | 7 | 5 | ||
4000 | 500 | - | 5 | 7 | 5 | ||
4500L V | 500 | - | 5 | 7 | 5 | ||
500 | 530 | - | 5 | 7 | 5 | ||
5100 | 500 | - | 5 | 7 | 5 | ||
60 H V | 530 | - | 5 | 7 | 5 | ||
IG Plus | 100 | 600 | - | 6 | 9 | 6 | |
100 V | 600 | - | 6 | 9 | 6 | ||
11.4-1 Uni | 600 | - | 6 | 9 | 6 | ||
120 | 600 | - | 6 | 9 | 6 | ||
120 V | 600 | - | 6 | 9 | 6 | ||
150 | 600 | - | 6 | 9 | 6 | ||
150 V | 600 | - | 6 | 9 | 6 | ||
30 V | 600 | - | 6 | 9 | 6 | ||
35 | 600 | - | 6 | 9 | 6 | ||
35 V | 600 | - | 6 | 9 | 6 | ||
50 | 600 | - | 6 | 9 | 6 | ||
50 V | 600 | - | 6 | 9 | 6 | ||
70 | 600 | - | 6 | 9 | 6 | ||
70 V | 600 | - | 6 | 9 | 6 | ||
Gamesa Corporación Tecnológica S.A. | Central inverter | 100 KW | 900 | - | 9 | 13 | 8 |
500 KW PLUS | 1,000 | with external transformer | 10 | 15 | 10 | ||
GE Energy | ProSolar II | PSC-4.000-L-QC | 1500 | Modified M V/H V transformer with multiple taps to adjust mpp window (min mpp 544 V for 15 FS3 modules in series; min mpp 782 for 15 FS4 modules in series). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 15 |
GEFRAN S.p.A. | Radius Industrial | AP V 100k-T-E | 1,000 | - | 10 | 15 | 10 |
Green Power | Power P V | 10 | 900 | - | 9 | 13 | 9 |
100 | 900 | - | 9 | 13 | 9 | ||
20 | 900 | - | 9 | 13 | 9 | ||
250 | 1,000 | - | 10 | 15 | 10 | ||
30 | 900 | - | 9 | 13 | 9 | ||
5 | 600 | - | 6 | 9 | 6 | ||
50 | 900 | - | 9 | 13 | 9 | ||
500 | 1,000 | - | 10 | 15 | 10 | ||
Helios Systems | HS | 100 | 900 | - | 9 | 13 | 9 |
HSC | 1000C | 900 | with external transformer | 9 | 13 | 9 | |
HSI | 500 | 900 | with external transformer | 9 | 13 | 9 | |
Hitachi Hi-Rel Power Electronics P Vt. Ltd. | 1000 KW | 1000 KW Solar PCS | 1000 | - | 10 | 15 | 10 |
IBC Solar AG | Serve Master | 1650 H V | 600 | - | 6 | 9 | 6 |
1650 M V | 450 | - | 4 | 6 | 4 | ||
3300 H V | 600 | - | 6 | 9 | 6 | ||
3300 M V | 450 | - | 4 | 6 | 4 | ||
4600 H V | 600 | - | 6 | 9 | 6 | ||
4600 M V | 450 | - | 4 | 6 | 4 | ||
IDS Trade AG | SOLO | 500 | 1,000 | with external transformer | 10 | 15 | 10 |
Ingeteam GmbH | IngeconSun | 500HE | 900 | with external transformer | 9 | 13 | 9 |
500HE (1000 V option) | 1,000 | with external transformer | 10 | 15 | 10 | ||
IngeconSun Lite | 2,5 | 550 | - | 5 | 8 | 5 | |
3,3 | 550 | - | 5 | 8 | 5 | ||
5 | 550 | - | 5 | 8 | 5 | ||
IngeconSun Power | 100 | 900 | - | 9 | 13 | 9 | |
50 | 900 | - | 9 | 13 | 9 | ||
60 | 900 | - | 9 | 13 | 9 | ||
70 | 900 | - | 9 | 13 | 9 | ||
80 | 900 | - | 9 | 13 | 9 | ||
90 | 900 | - | 9 | 13 | 9 | ||
IngeconSun Smart | 10 | 900 | - | 9 | 13 | 9 | |
12,5 | 900 | - | 9 | 13 | 9 | ||
15 | 900 | - | 9 | 13 | 9 | ||
20 | 900 | - | 9 | 13 | 9 | ||
25 | 900 | - | 9 | 13 | 9 | ||
30 | 900 | - | 9 | 13 | 9 | ||
JEMA | IF | 100 | 900 | - | 9 | 13 | 9 |
20 | 900 | - | 9 | 13 | 9 | ||
25 | 900 | - | 9 | 13 | 9 | ||
30 | 900 | - | 9 | 13 | 9 | ||
50 | 900 | - | 9 | 13 | 9 | ||
60 | 900 | - | 9 | 13 | 9 | ||
80 | 900 | - | 9 | 13 | 9 | ||
KACO Gerätetechnik GmbH | Blue planet 02xi Series | 1502xi | 550 | - | 5 | 7 | 5 |
2502xi | 550 | - | 5 | 8 | 5 | ||
3502xi | 600 | - | 6 | 9 | 6 | ||
5002xi | 600 | - | 6 | 9 | 6 | ||
Blue planet XP100-U | H2 | 600 | - | 6 | 9 | 6 | |
H4 | 600 | - | 6 | 9 | 6 | ||
Powador | 14.0 TR3 | 600 | - | 6 | 9 | 6 | |
1501xi | 500 | - | 5 | 7 | 5 | ||
16.0 TR3 | 600 | - | 6 | 9 | 6 | ||
18.0 TR3 | 600 | - | 6 | 9 | 6 | ||
2002 | 600 | - | 6 | 9 | 6 | ||
3002 | 600 | - | 6 | 9 | 6 | ||
3501xi | 500 | - | 5 | 7 | 5 | ||
4202 | 600 | - | 6 | 9 | 6 | ||
4501xi | 500 | - | 5 | 7 | 5 | ||
5002 | 600 | - | 6 | 9 | 6 | ||
6002 | 600 | - | 6 | 9 | 6 | ||
TS20-H V | 800 | - | 8 | 12 | 8 | ||
TS21-H V | 800 | - | 8 | 12 | 8 | ||
Powador XP | 100-H V | 1,000 | - | 10 | 15 | 10 | |
200-H V | 1,000 | - | 10 | 15 | 10 | ||
200-H V TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
250-H V | 1,000 | - | 10 | 15 | 10 | ||
250-H V TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
350-H V TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
XP100N-H2 | 600 | - | 6 | 9 | 6 | ||
XP100N-OD-H2 | 600 | - | 6 | 9 | 6 | ||
XP499-H V-TL | 1000 | - | 10 | 15 | 10 | ||
XP500-H V-TL | 1000 | - | 10 | 15 | 10 | ||
XP499-OD-TL | 1000 | - | 10 | 15 | 10 | ||
XP500-OD-TL | 1000 | - | 10 | 15 | 10 | ||
Kostal Solar Electric GmbH | Piko | 100 | 1,000 | - | 10 | 15 | 10 |
Leonics | Apollo GTP-500 | GTP-501 | 600 | - | 6 | 9 | 6 |
GTP-502 | 600 | - | 6 | 9 | 6 | ||
GTP-503 | 600 | - | 6 | 9 | 6 | ||
GTP-504 | 600 | - | 6 | 9 | 6 | ||
GTP-505 | 600 | - | 6 | 9 | 6 | ||
GTP-506 | 600 | - | 6 | 9 | 6 | ||
GTP-507 | 600 | - | 6 | 9 | 6 | ||
GTP-508 | 780 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system. | 7 | 11 | 7 | ||
GTP-509 | 780 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system. | 7 | 11 | 7 | ||
GTP-510 | 780 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system. | 7 | 11 | 7 | ||
GTP-511 | 780 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system. | 7 | 11 | 7 | ||
GTP-512 | 780 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 362 V). Several manual re-connections could be needed during the lifetime of the system. | 7 | 11 | 7 | ||
LTi REEnergy GmbH | P V Master-Station | P VMB 45-0270 | 900 | approved when used with an external transformer | 9 | 13 | 9 |
P VMB 45-0540 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMB 45-0810 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMB 45-1080 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMC 45-0270 | 900 | Approved when used with an external transformer | 9 | 13 | 9 | ||
P VMC 45-0540 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMC 45-0810 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMC 45-1080 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMI 45-0270 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMI 45-0540 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMI 45-0810 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VMI 45-1080 | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P Vmaster II | P VM 450-075 TT | 900 | - | 9 | 13 | 9 | |
P VM 450-090 TT | 900 | - | 9 | 13 | 9 | ||
P VM 450-100 TT | 900 | - | 9 | 13 | 9 | ||
P VM 450-110 TT | 900 | - | 9 | 13 | 9 | ||
P VM 450-132 EN/EM | 900 | with external transformer | 9 | 13 | 9 | ||
P VM 450-175 EN/EM | 900 | with external transformer | 9 | 13 | 9 | ||
P VM 450-230 EN/EM | 900 | with external transformer | 9 | 13 | 9 | ||
P VM 450-270 EN/EM | 900 | with external transformer | 9 | 13 | 9 | ||
P VM2 45-132EM | 900 | approved when used with external transformer | 9 | 13 | 9 | ||
P VM2 45-175EM | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VM2 45-230EM | 900 | approved when used with an external transformer | 9 | 13 | 9 | ||
P VM2 45-270EM | 900 | with external transformer | 9 | 13 | 9 | ||
P VM2 50-200EM | 900 | transformer :Yes – modified M V transformer with taps to adjust the mpp window up to an minimal Voltage of 450 V is mandatory. (new mpp window: 450-850 VDC) | 9 | 13 | 9 | ||
P VM2 50-305EM | 900 | transformer :Yes – modified M V transformer with taps to adjust the mpp window up to an minimal Voltage of 450 V is mandatory. (new mpp window: 450-850 VDC) | 9 | 13 | 9 | ||
Master Volt | SunMaster | QS 1200 | 450 | - | 4 | 6 | 4 |
QS 2000 | 450 | - | 4 | 6 | 4 | ||
QS 3200 | 450 | - | 4 | 6 | 4 | ||
QS 3200 Max-I | 450 | - | 4 | 6 | 3 | ||
QS 3500 Max-I | 325 | - | 3 | 4 | 3 | ||
QS 6400 | 450 | - | 4 | 6 | 4 | ||
QS 6400 Max-I | 450 | - | 4 | 6 | 3 | ||
XL | 10 | 550 | - | 5 | 8 | 5 | |
15 | 600 | - | 6 | 9 | 6 | ||
XS | 2000 | 450 | - | 4 | 6 | 6 | |
3200 | 600 | - | 6 | 9 | 6 | ||
4300 | 550 | - | 5 | 8 | 5 | ||
6500 | 600 | - | 6 | 9 | 6 | ||
Motech Industries Inc. | P VMate | 2800E | 600 | - | 6 | 9 | 6 |
2900U | 600 | - | 6 | 9 | 6 | ||
3800E | 600 | - | 6 | 9 | 6 | ||
3840U | 600 | - | 6 | 9 | 6 | ||
4000E | 600 | - | 6 | 9 | 6 | ||
4900U | 600 | - | 6 | 9 | 6 | ||
5000E | 600 | - | 6 | 9 | 6 | ||
5300U | 600 | - | 6 | 9 | 6 | ||
Nedap | Power Router | PR30S | 600 | - | 6 | 9 | 6 |
PR37S | 600 | - | 6 | 9 | 6 | ||
PR50S | 600 | - | 6 | 9 | 6 | ||
Nextronex Energy Systems | RAY-MAX | 150 | 1,000 | with external transformer | 10 | 15 | 10 |
150 (600 V) | 600 | To ensure a proper operation of this inverter in an 600 V DC system, it is mandatory to change the taps on the coupling transformer to 208 V. This action will allow to export power up to a minimum Voltage of 318 V DC. | 6 | 9 | 6 | ||
NIDEC | Solar Gate 5000 | P V9-M380NP | 1100 | - | - | 15 | - |
Nissin | SPM | SPM100-CS1B | 750 | - | 7 | 11 | 7 |
SPM250-CS1B | 750 | - | 7 | 11 | 7 | ||
SPM500-CS1B | 750 | - | 7 | 11 | 7 | ||
Oelmaier Technology GmbH | HS | 100 | 900 | - | 9 | 13 | 9 |
PAIRAN GmbH | pesos | P VI 2300 T | 500 | - | 5 | 7 | 5 |
Power Electronics | freesun HES | 0250OH | 900 | with external M V-transformer | 9 | 13 | 9 |
0300OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
0400OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
0500OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
0600OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
0700OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
0800OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
0900OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
1000OH | 900 | with external M V-transformer | 9 | 13 | 9 | ||
freesun L VT | 0020 | 900 | - | 9 | 13 | 9 | |
0025 | 900 | - | 9 | 13 | 9 | ||
0030 | 900 | - | 9 | 13 | 9 | ||
0035 | 900 | - | 9 | 13 | 9 | ||
0040 | 900 | - | 9 | 13 | 9 | ||
0050 | 900 | - | 9 | 13 | 9 | ||
0060 | 900 | - | 9 | 13 | 9 | ||
0080 | 900 | - | 9 | 13 | 9 | ||
0100 | 900 | - | 9 | 13 | 9 | ||
HEC | FS 1001CU-PU | 1000 | - | 10 | 15 | 10 | |
FS 1250CU-PU | 1000 | With tap adjustment to 510 V | 10 | 15 | 10 | ||
Power One Italy SpA | Aurora Lite | P VI-250.0-TL-CN | 1,000 | with external transformer | 10 | 15 | 10 |
P VI-500.0TL-CN | 1,000 | with external transformer | 10 | 15 | 10 | ||
Aurora Plus | P VI-110.0 | 1,000 | - | 10 | 15 | 10 | |
P VI-110.0-TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
P VI-165.0 | 1,000 | - | 10 | 15 | 10 | ||
P VI-165.0-TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
P VI-220.0 | 1,000 | - | 10 | 15 | 10 | ||
P VI-220.0-TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
P VI-275.0 | 1,000 | - | 10 | 15 | 10 | ||
P VI-275.0-TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
P VI-330.0 | 1,000 | - | 10 | 15 | 10 | ||
P VI-330.0-TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
P VI-55.0 | 1,000 | - | 10 | 15 | 10 | ||
P VI-Central-100 | 900 | - | 9 | 13 | 9 | ||
P VI-Central-100-TL | 900 | with external transformer | 9 | 13 | 9 | ||
P VI-Central-150 | 900 | - | 9 | 13 | 9 | ||
P VI-Central-150-TL | 900 | with external transformer | 9 | 13 | 9 | ||
P VI-Central-200 | 900 | - | 9 | 13 | 9 | ||
P VI-Central-200-TL | 900 | with external transformer | 9 | 13 | 9 | ||
P VI-Central-250 | 900 | - | 9 | 13 | 9 | ||
P VI-Central-250-TL | 900 | with external transformer | 9 | 13 | 9 | ||
P VI-Central-300 | 900 | - | 9 | 13 | 9 | ||
P VI-Central-300-TL | 900 | with external transformer | 9 | 13 | 9 | ||
P VI-Central-50 | 900 | - | 9 | 13 | 9 | ||
Aurora Trio | P VI-10.0-I-OUTD | 520 | - | 5 | 7 | 5 | |
P VI-12.0-I-OUTD | 520 | - | 5 | 7 | 5 | ||
Aurora Ultra | 1050.0-TL-OUTD-690 | 1,100 | with external transformer | 10 | 15 | 10 | |
1400.0-TL-OUTD-690 | 1,100 | with external transformer | 10 | 15 | 10 | ||
700.0-TL-OUTD-690 | 1,100 | with external transformer | 10 | 15 | 10 | ||
Aurora Uno | P VI-3.8-I-OUTD | 520 | - | 5 | 7 | 5 | |
P VI-4.6-I-OUTD | 520 | - | 5 | 7 | 5 | ||
RefuSol GmbH | Refu Sol | 100k | 850 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 414 V). Several manual re-connections could be needed during the lifetime of the system. | 8 | 12 | 8 |
160K | 850 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 414 V). Several manual re-connections could be needed during the lifetime of the system. | 8 | 12 | 8 | ||
500K | 950 | - | 9 | 14 | 9 | ||
630K | 950 | - | 9 | 14 | 9 | ||
RIELLO UPS | Helios Power | HP 100 | 800 | - | 8 | 12 | 8 |
HP 25 | 800 | - | 8 | 12 | 8 | ||
HP 33 | 800 | - | 8 | 12 | 8 | ||
HP 40 | 800 | - | 8 | 12 | 8 | ||
HP 64 | 800 | - | 8 | 12 | 8 | ||
HP 80 | 800 | - | 8 | 12 | 8 | ||
Satcon | PowerGate Plus | 100 KW | 900 | - | 9 | 13 | 9 |
135 KW | 600 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 310 V). Several manual re-connections could be needed during the lifetime of the system. | 6 | 9 | 6 | ||
1MW | 900 | - | 9 | 13 | 9 | ||
250 KW | 900 | - | 9 | 13 | 9 | ||
30 KW | 600 | - | 6 | 9 | 6 | ||
375 KW | 600 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 310 V). Several manual re-connections could be needed during the lifetime of the system. | 6 | 9 | 6 | ||
50 KW | 600 | - | 6 | 9 | 6 | ||
500 KW | 900 | - | 9 | 13 | 9 | ||
75 KW | 600 | - | 6 | 9 | 6 | ||
Solstice | 500 KW-CE | 900 | - | 9 | 13 | 9 | |
500 KW-UL/CSA | 600 | - | 6 | 9 | 6 | ||
Schneider Electric | Conext | Core XC 540 | 1,000 | - | 10 | 15 | 10 |
Core XC 630 | 1,000 | - | 10 | 15 | 10 | ||
Core XC 680 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 517 V). Several manual re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
Conext CL | CL25000E | 1000 | - | 10 | 15 | 10 | |
Schüco International KG | IPE | 100CT | 900 | - | 9 | 13 | 9 |
30CT | 900 | - | 9 | 13 | 9 | ||
60CT | 900 | - | 9 | 13 | 9 | ||
SGI plus | 1500 T | 500 | - | 5 | 7 | 5 | |
3500 T | 500 | - | 5 | 7 | 5 | ||
4500 T | 500 | - | 5 | 7 | 5 | ||
Shindengen | P V | P VS100T200-ID-DN-H1 | 650 | - | 6 | 9 | 6 |
SIAC | SOLEIL DSP | 10 | 780 | - | 7 | 11 | 7 |
100 | 780 | - | 7 | 11 | 7 | ||
125 | 780 | - | 7 | 11 | 7 | ||
15 | 780 | - | 7 | 11 | 7 | ||
20 | 780 | - | 7 | 11 | 7 | ||
200 | 780 | - | 7 | 11 | 7 | ||
25 | 780 | - | 7 | 11 | 7 | ||
250 | 780 | - | 7 | 11 | 7 | ||
30 | 780 | - | 7 | 11 | 7 | ||
40 | 780 | - | 7 | 11 | 7 | ||
400 | 780 | - | 7 | 11 | 7 | ||
50 | 780 | - | 7 | 11 | 7 | ||
500 | 780 | - | 7 | 11 | 7 | ||
60 | 780 | - | 7 | 11 | 7 | ||
80 | 780 | - | 7 | 11 | 7 | ||
Siemens AG | SIN VERT | 1000 MS TL | 1,000 | with external transformer | 10 | 15 | 10 |
1000MS | 900 | - | 9 | 13 | 9 | ||
1300 MS | 900 | - | 9 | 13 | 9 | ||
1400MS | 900 | - | 9 | 13 | 9 | ||
1500 MS TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
1700 MS | 900 | - | 9 | 13 | 9 | ||
2000 MS TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
350M | 900 | - | 9 | 13 | 9 | ||
420M | 900 | - | 9 | 13 | 9 | ||
500 M TL | 1,000 | with external transformer | 10 | 15 | 10 | ||
700MS | 900 | - | 9 | 13 | 9 | ||
850MS | 900 | - | 9 | 13 | 9 | ||
SIN VERT P VS | 1000 | 1,000 | wit external transformer | 10 | 15 | 10 | |
1200 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
1500 | 1,000 | with external transformer | 10 | 15 | 10 | ||
1800 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
2000 | 1,000 | with external transformer | 10 | 15 | 10 | ||
500 | 1,000 | with external transformer | 10 | 15 | 10 | ||
600 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
2400 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
SMA Solar Technology AG | Sunny Boy | 1200 | 400 | - | 4 | 6 | 4 |
1700 | 400 | - | 4 | 6 | 4 | ||
2000 HF | 700 | - | 7 | 10 | 7 | ||
2500 | 600 | - | 6 | 9 | 6 | ||
2500 HF | 700 | - | 7 | 10 | 7 | ||
3000 | 600 | - | 6 | 9 | 6 | ||
3000 HF | 700 | - | 7 | 10 | 7 | ||
3300 | 500 | - | 5 | 7 | 5 | ||
3800 | 500 | - | 5 | 7 | 5 | ||
5000US | 600 | - | 6 | 9 | 6 | ||
6000US | 600 | - | 6 | 9 | 6 | ||
7000US | 600 | - | 6 | 9 | 6 | ||
700US | 250 | - | 2 | 3 | 2 | ||
Sunny Central | 100 | 900 | - | 9 | 13 | 9 | |
1000M V | 1,000 | - | 10 | 15 | 10 | ||
1250 M V | 1,000 | - | 10 | 15 | 10 | ||
200 | 880 | - | 8 | 13 | 8 | ||
250 | 880 | - | 8 | 13 | 8 | ||
250HE | 880 | - | 8 | 13 | 8 | ||
350 | 880 | - | 8 | 13 | 8 | ||
400HE | 1,000 | - | 10 | 15 | 10 | ||
400M V | 1,000 | - | 10 | 15 | 10 | ||
500CP | 1,000 | with external transformer | 10 | 15 | 10 | ||
500HE | 1,000 | - | 10 | 15 | 10 | ||
500HE-20 | 1,000 | with external transformer | 10 | 15 | 10 | ||
500M V | 1,000 | - | 10 | 15 | 10 | ||
630CP | 1,000 | with external transformer | 10 | 15 | 10 | ||
630HE | 1,000 | - | 10 | 15 | 10 | ||
630HE-20 | 1,000 | with external transformer | 10 | 15 | 10 | ||
630M V | 1,000 | - | 10 | 15 | 10 | ||
720 CP | 1,000 | with external transformer | 10 | 15 | 10 | ||
800M V | 1,000 | - | 10 | 15 | 10 | ||
800CP | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
750CP-US | 1000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
760 CP | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 530 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
800HE-20 | 1,000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 500 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
900CP | 1,000 | transformer :Yes – modified M V/H V transformer with multiple taps to adjust mpp window (min mpp 545 V). Several manually re-connections could be needed during the lifetime of the system approved only for FS Series 3 | 15 | ||||
Sunny Mini Central | 4600A | 600 | - | 6 | 9 | 6 | |
5000A | 600 | - | 6 | 9 | 6 | ||
6000A | 600 | - | 6 | 9 | 6 | ||
7000H V | 800 | - | 8 | 12 | 8 | ||
Socomec | SUNSYS | P03 | 900 | with external transformer | 9 | 13 | 9 |
R01 | 900 | - | 9 | 13 | 9 | ||
R02 | 900 | - | 9 | 13 | 9 | ||
Solectria Renewables, LLC | P VI | 10 KW | 475 | - | 4 | 7 | 4 |
13 KW | 475 | - | 4 | 7 | 4 | ||
15 KW | 475 | - | 4 | 7 | 4 | ||
SOLUTRONIC GmbH | SOLEIL DSP | 10 | 780 | - | 7 | 11 | 7 |
100 | 780 | - | 7 | 11 | 7 | ||
125 | 780 | - | 7 | 11 | 7 | ||
15 | 780 | - | 7 | 11 | 7 | ||
20 | 780 | - | 7 | 11 | 7 | ||
200 | 780 | - | 7 | 11 | 7 | ||
25 | 780 | - | 7 | 11 | 7 | ||
250 | 780 | - | 7 | 11 | 7 | ||
30 | 780 | - | 7 | 11 | 7 | ||
40 | 780 | - | 7 | 11 | 7 | ||
400 | 780 | - | 7 | 11 | 7 | ||
50 | 780 | - | 7 | 11 | 7 | ||
500 | 780 | - | 7 | 11 | 7 | ||
60 | 780 | - | 7 | 11 | 7 | ||
80 | 780 | - | 7 | 11 | 7 | ||
Sputnik Engineering GmbH | SolarMax C | 100C | 900 | - | 9 | 13 | 9 |
20C | 900 | - | 9 | 13 | 9 | ||
25C | 900 | - | 9 | 13 | 9 | ||
300C | 900 | - | 9 | 13 | 9 | ||
30C | 900 | - | 9 | 13 | 9 | ||
330C-S V | 900 | with external transformer | 9 | 13 | 9 | ||
35C | 900 | - | 9 | 13 | 9 | ||
50C | 900 | - | 9 | 13 | 9 | ||
80C | 900 | - | 9 | 13 | 9 | ||
SolarMax TS | 100TS | 900 | - | 9 | 13 | 9 | |
300TS | 900 | - | 9 | 13 | 9 | ||
330TS-S V | 900 | with external transformer | 9 | 13 | 9 | ||
50TS | 900 | - | 9 | 13 | 9 | ||
80TS | 900 | - | 9 | 13 | 9 | ||
Sungrow Power Supply Co., Ltd. | SG | 100K3 | 900 | - | 9 | 13 | 9 |
SG 100KC-Outdoor | 600 | - | 6 | 9 | 6 | ||
SG 100Ku-Outdoor | 600 | - | 6 | 9 | 6 | ||
250K3 | 900 | - | 9 | 13 | 9 | ||
500K3 | 900 | - | 9 | 13 | 9 | ||
500KTL | 900 | with external transformer | 9 | 13 | 9 | ||
SG 500L V | 600 | - | 6 | 9 | 6 | ||
SG 500MX-M | 1000 | - | 10 | 15 | 10 | ||
50K3 | 900 | - | 9 | 13 | 9 | ||
630KTL | 1,000 | with external transformer | 10 | 15 | 10 | ||
SG 630MX | 1000 | - | 10 | 15 | 10 | ||
SG 630MX-E | 1000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
SG 750MX | 1000 | - | 10 | 15 | 10 | ||
SG 800MX | 1000 | transformer :Yes – modified M V transformer with multiple taps to adjust mpp window (min mpp 510 V). Several manually re-connections could be needed during the lifetime of the system. | 10 | 15 | 10 | ||
SG1000TS | 1000 | - | 10 | 15 | 10 | ||
SG1000TS-M V | 1000 | - | 10 | 15 | 10 | ||
SunTechnics | STW | 2000 | 800 | - | 8 | 12 | 8 |
2800 | 800 | - | 8 | 12 | 8 | ||
3800 | 800 | - | 8 | 12 | 8 | ||
5000 | 800 | - | 8 | 12 | 8 | ||
Vensys | Vencon | 1500 | 1120 | - | 10 | 15 | 10 |
Vencon | 2000 | 1120 | - | 10 | 15 | 10 | |
Vacon | NXP | CH 64 | 1,000 | with external transformer Sinusstrom Bea Ver for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 |
NX V | 0600-4 | 900 | - | 9 | 13 | 9 | |
Voltwerk electronics GmbH | VC | WL 110 | 1,000 | Voltwerk Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 |
WL 280 | 1,000 | Voltwerk Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | ||
WL 300 | 1,000 | Voltwerk Smart Connect for max. system Voltage of 1000 V is mandatory | 10 | 15 | 10 | ||
Xantrex Technologies Inc. | GT | 100-480 | 600 | - | 6 | 9 | 6 |
100E | 650 | - | 6 | 9 | 6 | ||
2.8 | 600 | - | 6 | 9 | 6 | ||
250-480 | 600 | - | 6 | 9 | 6 | ||
3.8 | 600 | - | 6 | 9 | 6 | ||
5.0 | 600 | - | 6 | 9 | 6 | ||
500E | 940 | - | 9 | 14 | 9 | ||
500-M VX | 600 | with external transformer | 6 | 9 | 6 | ||
540E | 1,000 | with external transformer | 10 | 15 | 10 | ||
630E | 1,000 | with external transformer 1000 V Version as well as an adjustment of the power tracking window range to an min. DC Voltage of 515 V is mandatory. | 10 | 15 | 10 | ||
XC | 540 | 1,000 | with external transformer | 10 | 15 | 10 | |
630 | 1,000 | with external transformer | 10 | 15 | 10 | ||
Zigor CORPORACIÓN S.A. | Sunzet | 100 T | 800 | - | 8 | 12 | 8 |
30 T | 800 | - | 8 | 12 | 8 | ||
50 T | 800 | - | 8 | 12 | 8 |